Permit # | Issued | Address | Pin | Work | Expand |
---|---|---|---|---|---|
100233233 | 04/18/2008 | 564 W RANDOLPH ST | 17093230030000 | REMOVE EXISTING ROOF COVERING, PRIME COAT DECK AND INSTALL RUBEROID MODIFIED BITUMEN MEMBRANE,VAPOR RETARDER, INSTALL 3 1/2 INCH OF ROOF INSULATION, INSTALL TWO LAYERS OF GAF MODIFIED MEMBRANE BITUMEN,INSTALL A NEW GAF RUBEROID WHITE MEMBRANE ROOF SYSTEM, INSTALL NEW SHEET METAL WALL FLASHING AND CURB FLASHINGS. ALL WORK SUBJECT TO FIELD INSPECTION. | Expand |
100292740 | 05/21/2009 | 564 W RANDOLPH ST | 17093230030000 | ERECT TWO SCAFFOLDING: MONDAY - FRIDAY, MASONRY RESTORATION, TUCK-POINTING, CAULKING 6/1/09 TO 5/31/10 | Expand |
100292859 | 05/22/2009 | 564 W RANDOLPH ST | 17093230030000 | ALL ELEVATIONS 1500 SQ. FT. TUCK-POINTING, 100 SQ. FT. CAULKING ONLY, NO STRUCTURAL WORK | Expand |
100400464 | 07/28/2011 | 564 W RANDOLPH ST | 17093230030000 | SCOPE: INTERIOR DEMOLITION OF EXISTING OFFICE SPACES AT 564 WEST RANDOLPH,1ST THRU 7TH FLOORS TOTAL. WORK INCLUDES REMOVAL OF ALL INTERIOR PARTITIONS, MILLWORK, FINISHES, ELECTRICAL OUTLETS, LIGHT FIXTURES AND PLUMBING. | Expand |
100402436 | 10/05/2011 | 564 W RANDOLPH ST | 17093230030000 | REMOVE CONNECTING WALKWAY BETWEEN BUILDINGS ON 6TH FLOOR AND INFILL THE OPENINGS. INFILL FLOOR OPENINGS AT ELEVATOR SHAFT ON ALL FLOORS. | Expand |
100405935 | 08/08/2011 | 564 W RANDOLPH ST | 17093230030000 | ERECT 1 PLATFORM SCAFFOLD FROM 8-8-11 TO 8-8-12 | Expand |
100411373 | 10/13/2011 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR BUILDOUT OF BUILDING LOBBY ENTRANCE. WORK INCLUDES GENERAL CONSTRUCTION, ELECTRICAL AND HVAC. NO PLUMBING OR STRUCTURAL.OFFICE | Expand |
100413957 | 10/07/2011 | 564 W RANDOLPH ST | 17093230030000 | REPLACE FIVE 30 TON PACKAGED A/C UNITS WITH FIVE JOHNSON CONTROLS 30 TON, WATER COOLED, SELF CONTAINED, R410A, LOCATED IN THE MACHINE ROOM ON THE FLOORS THEY SERVE FLOORS TWO THROUGH SIX. | Expand |
100415844 | 10/21/2011 | 564 W RANDOLPH ST | 17093230030000 | REPLACE BRICKS (ENTRANCE), INSTALL LIMESTONE CLAD (ENTRANCE S. WALL), REPAIR 40 SQ. FT. CONCRETE (N & E WALL), REPLACE 20 SQ. FT. OF BRICKS (N & E WALL), SPOT TUCKPOINT 60 SQ. FT. (N & E WALL). ALL WORK SAME AS EXISTING AT VARIED LOCATIONS. | Expand |
100416159 | 10/25/2011 | 564 W RANDOLPH ST | 17093230030000 | REPLACE EXISTING 1ST FLOOR WINDOWS WITH NEW INSULATED GLASS- SAME SIZE, SAME OPENING & SAME LOCATION | Expand |
100417935 | 12/02/2011 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ALTERATIONS TO 5TH FLOOR OFFICE SPACE PER ARCH PLANS.CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTION. | Expand |
100425236 | 02/07/2012 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ALTERATIONS FOR A SINGLE TENANT OFFICE ON THE SIXTH AND SEVENTH FLOORS TO INCLUDE AN INTER-CONNECTING STAIR AS PER PLANS | Expand |
100425614 | 01/24/2012 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ALTERATIONS TO SHELL AND CORE; INCLUDING RENOVATING ELEVATOR LOBBIES ON FLOORS: LL, 2ND-7TH FLOOR | Expand |
100426813 | 02/02/2012 | 564 W RANDOLPH ST | 17093230030000 | REPLACE THE EXISTING CARRIER ROOFTOP UNIT WITH ONE CARRIER 20 TON, TWO COMPRESSORS, SELF CONTAINED, AIR COOLED, R410A, LOCATED ON THE ROOF, SERVING THE SEVENTH FLOOR OFFICE. | Expand |
100427447 | 02/08/2012 | 564 W RANDOLPH ST | 17093230030000 | MODERNIZE ONE (1) 8 STOP TRACTION FREIGHT ELEVATOR UTILIZING MOTION CONTROL CONTROLLER. PURSUANT TO SCOPE OF WORK SUBMITTED. | Expand |
100427550 | 03/07/2012 | 564 W RANDOLPH ST | 17093230030000 | BASE BUILDING UPGRADES INCLUDING EMERGENCY GENERATOR, TELECOM, ACCESS CONTROL, COMMON AREA LIGHTING AND RESTROOMS. NO STRUCTURAL WORK. | Expand |
100429909 | 05/02/2012 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR BUILD-OUT OF A NEW RESTAURANT. MECHANICAL, ELECTRICAL, PLUMBING, REFRIG, MOPD, ARCH/FIRE, STRUCT AND ENVIRONMENTAL. (OPEN PLAN REVIEW) | Expand |
100430193 | 03/01/2012 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT # 100417935 TO CHANGE PLUMBING CONTRACTOR TO P. S. COYOTE, INC. | Expand |
100430204 | 03/01/2012 | 564 W RANDOLPH ST | 17093230030000 | REMVOE\REPLACE DRYWALL, COUNTER TOPS, MIRRORS, ACOUSTICAL TILES, FLOOR & WALL TILE & GRAB BARS. ALL WORK S.A.E. FOR REPLACEMENT OF 14 PLUMBING FIXTURES & 4 FLOOR DRAINS IN EXISTING 5TH. FLR. MENS (2) & WOMENS (2) BATHROOMS. | Expand |
100431906 | 03/23/2012 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT NUMBER 100425236 TO INCLUDE GLASS GUARDRAILS FOR AN INTER-CONNECTING STAIR ON THE SIXTH AND SEVENTH FLOORS AS PER PLANS | Expand |
100481201 | 07/15/2013 | 564 W RANDOLPH ST | 17093230030000 | CH DISTILLERY | Expand |
100440283 | 06/27/2012 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT #100429909 - PROVIDE A ROOF TOP UNIT TO SERVICE A RESTAURANT. STRUCTURAL INCLUDED FOR RTU SUPPORT AND OPENING IN THE DECK. PROVIDE VERTICAL PLATFORM LIFT INSTEAD OF ACCESSIBLE RAMP. | Expand |
100481177 | 03/28/2013 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ALTERATIONS FOR NEW OFFICE - BUSINESS USE - TO EXISTING OFFICE BUILDING FOR FULL FLOOR TENANT ON 2ND FLOOR. EXITS ARE EXISTING**SELF-CERTIFICATION - CONDITIONAL PERMIT: SUBJECT TO FIELD INSPECTIONS & AUDIT** | Expand |
100441984 | 12/13/2012 | 564 W RANDOLPH ST | 17093230030000 | NEW COMMON ROOF DECK AND RELATED PENTHOUSE FOR EGRESS AS PER PLANS**CERTIFIED CORRECTIONS- - SUBJECT TO FIELD INSPECTIONS & AUDIT ** | Expand |
100449056 | 10/10/2012 | 564 W RANDOLPH ST | 17093230030000 | 4TH FLOOR - INTERIOR ALTERATION OF EXISTING RESTROOM; INCLUDING PLUMBING, ELECTRICAL, VENT, ARCHITECTURE AND FINISHES. NO STRUCTURAL. EXISTING OFFICE | Expand |
100481203 | 05/17/2013 | 564 W RANDOLPH ST | 17093230030000 | CH DISTILLERY - BOX SIGN | Expand |
100450842 | 07/25/2012 | 564 W RANDOLPH ST | 17093230030000 | FIRE SERVICE UPGRADE OF (2) 8 STOP PSSENGER ELEVATORS TO INCLUDE AUTOMATIC RECALL. WORK TO BE MADE IN COMPLIANCE WITH ASME A17.1-1996 WITH 97 & 98 ADDENDUMS AS ADOPTED BY CITY OF CHICAGO 2001 ELEVATOR CODE. WORK TO BE SUBJECT TO FIELD INSPECTION BY CITY OF CHICAGO ELEVATOR BUREAU. | Expand |
100451118 | 08/22/2012 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR REMODEL OF 4TH FLOOR OFFICE SPACE PER ARCH PLANS. CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTION. | Expand |
100453093 | 10/16/2012 | 564 W RANDOLPH ST | 17093230030000 | 564 W RANDOLPH, SUITE 650 - INTERIOR TENANT BUILD OUT INCLUDING; ARCH, ELEC, VENT, PLUMBING AND FINISHES. NO STRUCTURAL. (CONDITIONAL APPROVED SUBJECT TO A FIELD INSPECTION) | Expand |
100457057 | 09/17/2012 | 564 W RANDOLPH ST | 17093230030000 | SELF-CERT PROJECT CONSISTS OF A TENANT IMPROVEMENT OF AN EXISTING OFFICE ON THE THIRD FLOOR. NO EXTERIOR WORK. INTERIOR MODIFICATIONS TO INCLUDE REMOVAL OF NON-BEARING PARTITION WALLS AND REPLACEMENT WITH CARPET FLOORING, AND ACOUSTICAL CEILING PANEL SYSTEM. EXISTING MECHANICAL, ELECTRICAL, PLUMBING, FIRE-LIFE SAFETY, AND FIRE SUPPRESSION SYSTEMS TO BE MODIFIED FOR NEW ROOM CONFIGURATIONS. MECHANICAL, ELECTRICAL, PLUMBING, FIRE-LIFE SAFETY, AND FIRE SUPRESSION SYSTEMS TO BE ENGINEERED. | Expand |
100462188 | 10/11/2012 | 564 W RANDOLPH ST | 17093230030000 | CHANGE GC TO BEAR CONSTRUCTION, VENT CONTRACTOR TO ENVIRO MECHANICAL AND PLUMBER TO JOHN'S PLUMBING FOR PERMIT 100457057 | Expand |
100470484 | 12/12/2012 | 564 W RANDOLPH ST | 17093230030000 | PLUMBING ONLY, REPLACE 5 FIXTURES. | Expand |
100470689 | 12/12/2012 | 564 W RANDOLPH ST | 17093230030000 | REPLACE THE EXISTING SPLIT SYSTEM WITH ONE CARRIER 15 TON SPLIT SYSTEM, AIR COOLED, R410A, LOCATED ON THE ROOF. THE UNIT SERVES A FIRST FLOOR COMMERCIAL SPACE SUITE 1-E. | Expand |
100473990 | 01/14/2013 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT # 100453093 TO CHANGE PLUMBING CONTRACTOR TO PRAIRIE PLUMBING CONTRACTORS | Expand |
100473992 | 01/14/2013 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT # 100449056 TO CHANGE PLUMBING CONTRACTOR TO PRAIRIE PLUMBING CONTRACTORS | Expand |
100474695 | 01/18/2013 | 564 W RANDOLPH ST | 17093230030000 | STRUCTURAL REINFORCEMENT, ADD NEW STEEL BEAMS AS PER STRUCTURAL PLANS. | Expand |
100475034 | 02/26/2013 | 564 W RANDOLPH ST | 17093230030000 | *********** SELF CERTIFICATION*************INTERIOR GROUND FLOOR BUILD-OUT FOR UNIT 1E PER PLANS | Expand |
100477650 | 02/13/2013 | 564 W RANDOLPH ST | 17093230030000 | ALL WORK IN BSMT ONLY: REPLACE DRYWALL 3600SF & DOORS. ELECTRICAL ON SEPARATE PERMIT- ALL WORK SAME AS EXISTING | Expand |
100479523 | 02/28/2013 | 564 W RANDOLPH ST | 17093230030000 | INSTALL NEW ENTERIOR DOORS & 1 NEW ROLLING DOOR WITH BALLARS AS PER PLANS. | Expand |
100484992 | 04/23/2013 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT #100475034 FOR MEP CHANGES PER PLANS. | Expand |
100484997 | 08/27/2013 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ILLUMINATED SIGN FACING W. RANDOLPH | Expand |
100484998 | 08/27/2013 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ILLUMINATED SIGN FACING N. JEFFERSON ST. | Expand |
100485256 | 04/10/2013 | 564 W RANDOLPH ST | 17093230030000 | INSTALL ONE (1) 9-STOP, 2500LB.CAP, EXISTING WEST PASSENGER ELEVATOR PROVIDE ONE NEW OPENING TOP TERMINAL. PURSUNAT TO SCOPE OF WORK AND PLANS SUBMITTED. | Expand |
100485295 | 05/01/2013 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ALTERATIONS TO A SINGLE TENANT OFFICE SPACE ON 7 TH FLOOR AS PER PLANS. | Expand |
100498088 | 10/23/2017 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF (1) NON ILLUMINATED BANNER TO BE MOUNTED TO THE SOUTH BUILDING ELEVATION | Expand |
100499989 | 07/16/2013 | 564 W RANDOLPH ST | 17093230030000 | CHANGE PLUMBER TO EFFICIENT PLUMBING AND HVAC CONTRACTOR TO SPARTAN SHEET METAL FOR PERMIT 100481177 | Expand |
100524021 | 01/27/2014 | 440 W RANDOLPH ST | 17093230030000 | INTERIOR DEMOLITION OF NON LOAD BEARING PARTITIONS ON 1ST AND 2ND FLOORS PER PLAN | Expand |
100578077 | 01/26/2015 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR ALTERATIONS TO AN EXISTING OFFICE SPACE ON THE SIXTH FLOOR (NO MECHANICAL WORK) AS PER PLANS. | Expand |
100617655 | 10/07/2015 | 564 W RANDOLPH ST | 17093230030000 | DECOMMISSION (1) 4000# CAP., 8-STOP, GEARED, FREIGHT ELEVATOR (WEST). (EV005587) | Expand |
100675165 | 10/17/2016 | 564 W RANDOLPH ST | 17093230030000 | SOUTH ELEVATION. TUCKPOINT AS NECESSARY. REPLACE 40 BRICKS. CAULK AS NECESSARY. 1000 SQ. FT. | Expand |
100675474 | 11/01/2016 | 564 W RANDOLPH ST | 17093230030000 | INTERIOR REMODEL OF EXISTING OFFICE SPACE 1,700 SF SCOPE OF WORK AREA12,800 SF - ENTIRE FLOOR AREA | Expand |
100702330 | 05/11/2017 | 564 W RANDOLPH ST | 17093230030000 | SELF-CERT. INTERIOR RENOVATION OF EXISTING RESTAURANT AT 1ST FLOOR AND BASEMENT IN AN EXISTING 7 STORY TYPE-1A BUILDING. TOTAL RENOVATED RESTAURANT AREA IS 7,150 SF. EXISTING USE RESTAURANT/C-2 SMALL ASSEMBLY, PROPOSED USE RESTAURANT/C-2 SMALL ASSEMBLY. | Expand |
100698706 | 04/03/2017 | 564 W RANDOLPH ST | 17093230030000 | TUCKPOINT AS NEEEDED, REPLACE BRICK(30), CAULK AS NEEDED- ALL WORK SAME AS EXSITING | Expand |
100738287 | 12/04/2017 | 564 W RANDOLPH ST | 17093230030000 | NORTH ELEVATION, TUCK-POINT 1000 SQ. FT., ONLY; SUBJECT TO FIELD INSPECTIONS | Expand |
100738917 | 02/06/2018 | 564 W RANDOLPH ST | 17093230030000 | FLAT-CUT STEEL SIGN (BELLEMORE - 1'11" X 12'5" - 24 SQ FT) | Expand |
100733374 | 10/31/2017 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT #100702330 TO CHANGE THE VENTILTION & REFRIGERATION CONTRACTOR OF RECORD HANIC HEATING & AIR CONDITIONING, INC. | Expand |
100738918 | 04/11/2018 | 564 W RANDOLPH ST | 17093230030000 | NON-ILLUMINATED ALUMINUM PROJECTING SIGN (ARTISTIC AMERICAN - PEACOCK GRAPHICS - EST. 2017 - WEST LOOP, CHICAGO - 3' X'3' - 9 SQ FT) | Expand |
100768339 | 06/19/2018 | 564 W RANDOLPH ST | 17093230030000 | NORTH ELEVATION, REPAIR/REPLACE 110 BRICKS, TUCK-POINT 1000 SQFT | Expand |
100809094 | 03/14/2019 | 564 W RANDOLPH ST | 17093230030000 | ¿ALL ELEVATIONS, REPAIR/REPLACE 100 BRICKS, TUCK-POINT 500 SQ. FT., ONLY¿ | Expand |
100866797 | 03/26/2020 | 564 W RANDOLPH ST | 17093230030000 | TENANT INTERIOR ALTERATIONS OF EXISTING/PREVIOUS TENANT BUILD-OUT. ALL WALL, CEILING AND TRIM FINISHES TO BE CLASSIFICATION "CLASS 1" FLAME SPREAD INDEX OF 0 TO 25 AND SMOKE DENSITY OF 150 IN ENCLOSED VERTICAL EXIT WAYS AND 300 IN OTHER EXIT WAYS AND ROOMS OR AREAS.ALL FLOOR COVERINGS/FINISHES ARE TO BE CLASSIFICATION "A". CRITICAL REDIANT FLUX AT 0.45 WATTS PER SQUARE CENTIMETER OR HIGHER. | Expand |
100908083 | 02/04/2021 | 564 W RANDOLPH ST | 17093230030000 | REPLACEMENT OF HOIST CABLES ON ONE(1) 2500LB CAPACITY, 7-FLOOR, 350FPM, PASSENGER ELEVATOR, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV005587) CAR #2 | Expand |
100914934 | 08/13/2021 | 564 W RANDOLPH ST | 17093230030000 | SPR 2019 CBRC: EXTERIOR LEVEL 1 ALTERATIONS TO EXISTING ROOF DECK. REPLACING EXISTING WOOD DECKING AND RAILS WITH NEW SIMILAR MATERIALS. EXISTING STRUCTURAL SUPPORT TO REMAIN. INSTALL NEW ALUMINUM FRAME PERGOLA AND EXTEND EXISTING GAS LINE TO NEW BUILT-IN GRILL. SECURE EXISTING ELECTRICAL OUTLETS, LIGHTING, AND LIFE SAFETY DEVICES TO NEW RAILING. NO HVAC, PLUMBING, OR CHANGE IN USE. TO EXISTING 7 STORY BUILDING PER PLANS | Expand |
100916141 | 04/16/2021 | 564 W RANDOLPH ST | 17093230030000 | REPAIR/REPLACE INTERIOR FINISHES AT EXISTING RESTAURANT, REFINISH FLOORS, INSTALL STONE FASCIA AT INTERIOR WALL, INSTALL CEILING SUSPENDED DECOR AND COLUMN CLADDING, (SEPARATE ELECTRICAL PERMIT REQ'D) NO CHANGE IN USE; NO CHANGE TO CAPACITY/OCCUPANCY; NO FLOOR LAYOUT CHANGES | Expand |
100926682 | 06/23/2021 | 564 W RANDOLPH ST | 17093230030000 | SELF CERT 2019 CBRC: INTERIOR ALTERATION OF EXISTING 1ST FLOOR RESTARUANT IN EXISTING 7 STORY 1A BUILDING. INSTALL NEW KITCHEN EQUIPMENT PER PLANS. (OCCUPANCY A-2, TYPE 1A CONSTRUCTION) NO CHANGE IN OCCUPANCY OR USE. | Expand |
100933116 | 03/22/2022 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF (1) BLADE SIGN TO READ: ALLA VITA ITALIAN.SIGN SIZE: 2'-3" X 8'-0" | Expand |
101015246 | 05/31/2023 | 564 W RANDOLPH ST | 17093230030000 | SELF CERT 2019 CBRC: INTERIOR DEMO ONLY OF NON LOAD BEARING PARTITIONS AT EXISTING OFFICES ON FLOORS 3, 4, 5 AND 6 AS PER PLANS. B-BUSINESS. 1A CONSTRUCTION | Expand |
101018782 | 08/21/2023 | 564 W RANDOLPH ST | 17093230030000 | SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO OFFICES ON FLOORS 3 THRU 6. WORK TO INCLUDE NEW PARTITIONS, MECHANICAL, ELECTRICAL, PLUMBING AS PER PLANS. STRUCTURAL PEER REVIEW INCLUDED. B-BUSINESS. 1A CONSTRUCTION | Expand |
101035973 | 11/21/2023 | 564 W RANDOLPH ST | 17093230030000 | SELF-CERT 2019 CBRC: REVISION TO PERMIT #101018782 TO KEEP AN EXISTING 6TH FLOOR COMMUNICATING STAIR AND TO ADD A FIRE RATED PARTITION AROUND IT. NO CHANGE TO EXISTING USE. (OCCUPANCY B / CONSTRUCTION TYPE 1A) | Expand |
101039933 | 02/08/2024 | 564 W RANDOLPH ST | 17093230030000 | SPR 2019 CBRC: INTERIOR ALTERATIONS TO EXISTING 6TH FLOOR OFFICE SPACE TO BUILD-OUT OFFICE SERVER ROOM. WORK TO INCLUDE NEW PARTITIONS, MECHANICAL, ELECTRICAL AND PLUMBING. NO CHANGE TO EXISTING USE. (OCCUPANCY B / CONSTRUCTION TYPE 1A) | Expand |
B100223340 | 02/11/2008 | 564 W RANDOLPH ST | 17093230030000 | MONTHLY MAINTENANCE | Expand |
B100414630 | 10/13/2011 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF EIGHT (8) ELECTRONIC SUB-METERS FOR THE 120/208 VOLT LIGHTING AND RECEPTACLE PANELS. INSTALLATION OF EIGHT (8) ELECTRONIC SUB-METERS FOR THE 277/480 VOLT HVAC EQUIPMENT. ALL SIXTEEN METERS TO BE INTERCONNECTED THROUGH DATA CABLING BACK TO BUILDING ENGINEERS COMPUTER. | Expand |
B100414942 | 10/19/2011 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF LOW VOLTAGE CABLES FOR TELEPHONES 10(RJ11C) LOCATIONS CUST.-STERLING BAY FLOOR 1 CUST. TELE# 312-454-3843. ANY QUESTIONS PLEASE CALL TIM MCGUIRE(SUPV. ELEC.AT&T) 312-220-2408 | Expand |
B100423614 | 01/05/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF 150 KW NATURAL GAS GENERATOR | Expand |
B100424641 | 01/13/2012 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OF ELECTRICAL CONTRACTOR ON PERMIT NUMBER 100417935 | Expand |
B100424799 | 01/16/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALL CONDUIT SYSTEM FOR FIRE ALARM SYSTEM | Expand |
B100424800 | 01/16/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALL 2" CONDUIT SYSTEM RISER FOR PHONE DATA SYSTEMS | Expand |
B100424858 | 01/16/2012 | 564 W RANDOLPH ST | 17093230030000 | NEW WIRING IN THE BATHROOMS LOCATED AT 6TH AND 7TH FLOOR. 2 BATHROOM'S ON THE 7TH FLOOR, ONE BATHROOM ON THE 6TH FLOOR | Expand |
B100425294 | 01/19/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF NON REQUIRED FIRE ALARM SYSTEM, BURGLAR ALARM READERS AND ENTRY INTERCOM | Expand |
B100428316 | 02/15/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF LOW VOLTAGE 24 VDC PEDESTRIAN AUTOMATIC DOOR OPERATOR. 110V FEED TO HEADER BY OTHERS. | Expand |
B100429641 | 02/27/2012 | 564 W RANDOLPH ST | 17093230030000 | CONFEENCE RM AUDIO VIDEO | Expand |
B100431109 | 03/13/2012 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OF ELECTRICAL CONTRACTOR ON PERMIT NUMBER 100424799 | Expand |
B100431911 | 03/15/2012 | 564 W RANDOLPH ST | 17093230030000 | TEMPORARY POWER HOOK UP | Expand |
B100453070 | 10/03/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALL EIGHT TOTAL LED LIGHT FIXTURES ON THE EXTERIOR OF THE BUILDING. POWER FROM A EXISTING 120 VOLT CIRCUIT THAT FED OLD EXTERIOR FIXTURES. | Expand |
B100460889 | 10/09/2012 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OF ELECTRICAL CONTRACTOR TO PERMIT# 100457057 | Expand |
B100462402 | 10/14/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALL CAMERAS AND A CARD ACCESS SYSTEM | Expand |
B100462481 | 10/25/2012 | 564 W RANDOLPH ST | 17093230030000 | REPLACE THE EXISTING 14 CIRCUIT EMERGENCY PLUG FUSE PANEL WITH NEW 28 CIRCUIT PLUG FUSE PANEL. | Expand |
B100465728 | 11/09/2012 | 564 W RANDOLPH ST | 17093230030000 | STRUCTURED CABLING (LOW-VOLTAGE DATA) INSTALLATION | Expand |
B100466719 | 11/12/2012 | 564 W RANDOLPH ST | 17093230030000 | AUDIO / VISUAL WORK AT STARBUCKS | Expand |
B100466864 | 11/30/2012 | 564 W RANDOLPH ST | 17093230030000 | INSTALLATION OF THREE ELECTRIC BASEBOARD HEATERS IN LOBBY AREA. INSTALL THREE DEDICATED 120 VOLT CIRCUITS. | Expand |
B100477455 | 02/12/2013 | 564 W RANDOLPH ST | 17093230030000 | RELOCATE EXISTING WIRING FOR A NEW FLOOR PLAN IN THE BASEMENT. | Expand |
B100491299 | 05/20/2013 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OUTLET | Expand |
B100490627 | 05/15/2013 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OF CONTRACTOR TO EXISTING PERMIT NUMBER 100481177 | Expand |
B100495374 | 06/13/2013 | 564 W RANDOLPH ST | 17093230030000 | FURNISH & INSTALL 106 VOICE/DATA STATION LOCATIONS | Expand |
B100692297 | 02/24/2017 | 564 W RANDOLPH ST | 17093230030000 | ADDING (4) OUTLETS | Expand |
B100686887 | 01/18/2017 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OF ELECTRICAL CONTRACTOR FOR AT 564 W RANDOLPH 4TH FLOOR FOR ORIGINAL PERMIT # 100675474 | Expand |
B100713990 | 07/06/2017 | 564 W RANDOLPH ST | 17093230030000 | CHANGE OF ELECTRICAL CONTRACTOR TO DEXTER ELECTRIC FOR BUILDING PERMIT NUMBER 100702330. | Expand |
B200001917 | 11/17/2023 | 564 W RANDOLPH ST | 17093230030000 | REVISION TO PERMIT #101018782 TO CHANGE OF PLUMBING CONTRACTOR. | Expand |
B100967878 | 04/19/2022 | 564 W RANDOLPH ST | 17093230030000 | INSTALL CONDUIT 1" FOR SINGLE CIRCUIT | Expand |
B101030774 | 09/30/2023 | 564 W RANDOLPH ST | 17093230030000 | **FIRE ALARM PERMIT**TENANT BUILDOUT ON FLOORS 3,4,5, & 6 IN AN EXISTING HIGH-RISE BUILDING. | Expand |