The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EAST ELEVATION AT GRADE SPALLING BRICKS, OPEN MORTAR FROM NORTH TO SOUTH, SOUTH EAST CORNER- DOOR AT 50TH PL- LOOSE BRICKS | 5000 S HALSTED ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST 2ND LEVEL AND SOUTH 2ND LEVEL, AT GRADE ALL ELEVATIONS BROKEN PANES | 5000 S HALSTED ST | PERIODIC | FAILED | View |
FLAKY INTERIOR PAINT | FLAKING CHIPPED PAINT ON ALL WINDOW WOOD SUFACES AT GRADE | 5000 S HALSTED ST | PERIODIC | FAILED | View |
POST OWNER COMM VACNT BLDG | POST OWNERSHIP MANAGEMENT ID ON PROPERTY | 5000 S HALSTED ST | PERIODIC | FAILED | View |
REPAIR COPING | EAST AND SOUTH (SOUTH CORNER) COPING STONES WASHED OUT MORTAR | 5000 S HALSTED ST | PERIODIC | PASSED | View |
CHIMNEY | CHIMNEY'E WASHED OUT MORTAR | 5000 S HALSTED ST | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM 5 YEAR GOVERNOR SAFETY TEST ON NORTH AND SOUTH FREIGHT ELEVATORS | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | INSTALL FIRE EXTINGUISHERS IN NORTH AND SOUTH FREIGHT ELEVATORS MACHINE | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR/REPLACE LIGHTING IN MACHINE ROOM. BOTH UNITS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE 110 VAC GFCI OUTLET IN MACHINE ROOM. BOTH ELEVATORS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REMOVE/CAP FIRE SPRINKLER HEAD(S) IN MACHINE ROOM AND OVERHEAD AREA. ALL ELEVATORS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SERVICE/UPDATE FIRE EXTINGUISHER IN MACHINE ROOMS. ALL UNITS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM 5 YEAR GOVERNOR SAFETY TEST ON SOUTH FREIGHT ELEVATOR (PREVIOUSLY CITED) | 5000 S HALSTED ST | PERIODIC | PASSED | View |
REPAIR COPING | EAST AND SOUTH (SOUTH CORNER) COPING STONES WASHED OUT MORTAR | 5000 S HALSTED ST | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY'E WASHED OUT MORTAR | 5000 S HALSTED ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION, 2ND FLOOR - BULGE IN MASONRY WALL EXTENDING 2ND FOOR TO ROOF. WALL OUT OF PLUMB WITH SHIFTING BRICK.*PLANS AND PERMIT REQUIRED FOR REPAIRS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION - OPEN SILL JOINTS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION 1ST FLOOR - BROKEN WINDOW PANE. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
HEATING PLANT ENCLOSURE | BASEMENT BOILER ROOM - PORTIONS OF CEILING MISSING FIRE RATED ASSEMBLY, PIPE PENETRATIONS INTO ROOM NOT PROPERLY FIRE SEALED. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | BASEMENT SOUTH END OF BUILDING - BEARING WALL REMOVED, BEAM UNSUPPORTED. *PLANS AND PERMIT REQUIRED FOR REPAIRS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | BASEMENT SOUTH END OF BUILDING - BEARING WALL REMOVED, STEEL BEAM BEING SUPPORTED BY 4X6 TIMBER COLUMN WITHOUT FOOTING. *PLANS AND PERMIT REQUIRED FOR REPAIRS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR NORTH OFFICES - WATER DAMAGE TO CEILING AND WALLS, MISSING PLASTER. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATEGORY 5 TEST. PROVIDE DOCUMENTATION. NORTH ELEVATOR. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE EMERGENCY LIGHT AND BELL INSIDE ELEVATOR. ALL UNITS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FOR SAFETY. PROVIDE EMERGECNY STOP SWITCH INSIDE ELEVATOR. ALL UNITS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | FOR SAFETY. PROVIDE EMERGENCY STOP SWITCH IN PIT AREA. ALL ELEVATORS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SOUTH ELEVATOR. PROVIDE HOISTWAY DOOR UNLOCKING DEVICE AT TOP LANDING. MUST BE SECURED BEHIND A LOCKED PANAL. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE LIGHTING IN PIT AREA WITH 110 VAC GFCI. | 5000 S HALSTED ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE SPRING FOR COUNTERWEIGHT IN PIT. | 5000 S HALSTED ST | PERMIT | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REAR ELEVATOR. CATEGORY 1 TEST PAST DUE. PROVIDE DOCUMENTATION. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PERFORM CATEGORY 1 TEST. PROVIDE DOCUMENTATION. SOUTH ELEVATOR. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE EMERGENCY COMMUNICATION DEVICE PERNMANTANTLY MOUNTED INSIDE ELEVATOR CAB. MUST DIAL 24 HOUR LIVE OPERATOR AND BROADCAST BUILDING ADDRESS AND ELEVATOR NUMBER PER CODE. NOT TO DIAL 911. ALL ELEVATORS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | SOUTH ELEVATOR. PROVIDE CAR TOP OPERATING STATION PER A17.3. MUST ALSO INCLUDE CAR TOP LIGHTING AND EMERGENCY STOP SWITCH. PERMIT REQUIRED FOR CAR TOP INSPECTION STATION INSTALLATION. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CODE COMPLIANT BUFFER FOR COUNTERWEIGHT. NORTH ELEVATOR. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CAR LOAD CAPACITY PLATES INSIDE ELEVATOR. ALL ELEVATORS. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | ROTTED EXTERIOR DOOR | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE EMERGENCY COMMUNICATION DEVICE PERNMANTANTLY MOUNTED INSIDE ELEVATOR CAB. MUST DIAL 24 HOUR LIVE OPERATOR AND BROADCAST BUILDING ADDRESS AND ELEVATOR NUMBER PER CODE. SOUTH ELEVATOR. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | PROVIDE CODE COMPLIANT BUFFER FOR COUNTERWEIGHT. NORTH ELEVATOR. | 5000 S HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR ELECT ELEVA | REPAIR/REPLACE EMERGENCY PHONE. REAR ELEVATOR. | 5000 S HALSTED ST | PERIODIC | FAILED | View |