Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | REAR PORCH ... 3 STORIES. DOUBLE WIDE PORCH. ALL STRUCTURAL COLUMN FOOTINGS ARE OF AN UNDETERMINED DEPTH. THE PORCH DECK COLUMNS ARE STACK JOINTED WITH NO STRUCTURAL (BOLTED) LAP JOINT. THE CRITICAL BEAM TO COLUMN STRUCTURAL CONECTION IS DEFICIENT IS THAT THESE JOINTS ARE HELD TOGETHER WITH UNDERSIZED (!/4") STEEL BRACKETS.THE PORCH DECK(S) FLOOR JOISTS HAVE UNDERSIZED (2"X6") BOARDS THAT ARE OVERSPANNED (18") SUPPORTING 3 LEVELS OF DECKS.THE STAIR SYSTEM SUPPORT COLUMNS HAVE DEFICIENT LAP JOINTS (8" LAP W/ 2 BOLTS). ALL BANISTERS ARE WITHOUT AN INTERMEDIATED SUPPORT POST.ALL STRUCTURAL COLUMNS ARE OVERNOTHCED. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR BALCONY | FRONT BALCONIES ... 4 OF 6 BALCONIES (2CD, 3RD FLOORS) ... SEVERELY RUSTED / PITTED / WARPED RIM BEAMS AND UNDERSIZED PLATE STEEL DECKING. THE BANISTERS ARE TOO LOW AT 36". PERMIT REQUIRED FOR REPAIRS. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | THE BRICK COLUMN JUST SOUTH OF THE FRONT BALCONIES HAS MILTIPLE STEP FRACTURES AND ERODED BRICK MORTAR. PERMIT REQUIRED FOR REPAIRS. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH ... 3 STORIES. DOUBLE WIDE PORCH. ALL STRUCTURAL COLUMN FOOTINGS ARE OF AN UNDETERMINED DEPTH. THE PORCH DECK COLUMNS ARE STACK JOINTED WITH NO STRUCTURAL (BOLTED) LAP JOINT. THE CRITICAL BEAM TO COLUMN STRUCTURAL CONECTION IS DEFICIENT IS THAT THESE JOINTS ARE HELD TOGETHER WITH UNDERSIZED (!/4") STEEL BRACKETS.THE PORCH DECK(S) FLOOR JOISTS HAVE UNDERSIZED (2"X6") BOARDS THAT ARE OVERSPANNED (18") SUPPORTING 3 LEVELS OF DECKS.THE STAIR SYSTEM SUPPORT COLUMNS HAVE DEFICIENT LAP JOINTS (8" LAP W/ 2 BOLTS). ALL BANISTERS ARE WITHOUT AN INTERMEDIATED SUPPORT POST.ALL STRUCTURAL COLUMNS ARE OVERNOTHCED. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO COMPLETE ANNUAL INSPECTION. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO COMPLETE ANNUAL INSPECTION. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
PARAPET | SOUTH AND EAST ELEVATION -PARAPET WALL SPALLING BRICK AND WASHED OUT MORTAR. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION- GRADE TO 1ST FLOOR SPALLING BRICK AND WASHED OUT MORTAR. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | FRONT INTERIOR STAIRS 3RD FLOOR SKYLIGHT GLASS PANE CRACKED. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | FRONT INTERIOR STAIRS 1ST,2ND AND 3RD FLOOR NO EMERGENCY LIGHTS. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | FRONT 1ST FLOOR FOYER TILE FLOOR CRACKED | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE NORTH AND SOUTH ELEVATION-PARPETWALL WASHED OUT MORTAR.NORTH EAST OVERHEAD GARAGE DOOR HEADER SAGGING. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE LOCKED WITH PADLOCK. | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BUILDING INTERIOR | 4843 S MICHIGAN AVE | PERIODIC | FAILED | View |