Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 4:45 PM
PIN: 20101080060000
Property Address: 4843 S MICHIGAN AVE
City - Zip: CHICAGO - 60615
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70118
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM REAR PORCH ... 3 STORIES. DOUBLE WIDE PORCH. ALL STRUCTURAL COLUMN FOOTINGS ARE OF AN UNDETERMINED DEPTH. THE PORCH DECK COLUMNS ARE STACK JOINTED WITH NO STRUCTURAL (BOLTED) LAP JOINT. THE CRITICAL BEAM TO COLUMN STRUCTURAL CONECTION IS DEFICIENT IS THAT THESE JOINTS ARE HELD TOGETHER WITH UNDERSIZED (!/4") STEEL BRACKETS.THE PORCH DECK(S) FLOOR JOISTS HAVE UNDERSIZED (2"X6") BOARDS THAT ARE OVERSPANNED (18") SUPPORTING 3 LEVELS OF DECKS.THE STAIR SYSTEM SUPPORT COLUMNS HAVE DEFICIENT LAP JOINTS (8" LAP W/ 2 BOLTS). ALL BANISTERS ARE WITHOUT AN INTERMEDIATED SUPPORT POST.ALL STRUCTURAL COLUMNS ARE OVERNOTHCED. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR BALCONY FRONT BALCONIES ... 4 OF 6 BALCONIES (2CD, 3RD FLOORS) ... SEVERELY RUSTED / PITTED / WARPED RIM BEAMS AND UNDERSIZED PLATE STEEL DECKING. THE BANISTERS ARE TOO LOW AT 36". PERMIT REQUIRED FOR REPAIRS. 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL THE BRICK COLUMN JUST SOUTH OF THE FRONT BALCONIES HAS MILTIPLE STEP FRACTURES AND ERODED BRICK MORTAR. PERMIT REQUIRED FOR REPAIRS. 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH ... 3 STORIES. DOUBLE WIDE PORCH. ALL STRUCTURAL COLUMN FOOTINGS ARE OF AN UNDETERMINED DEPTH. THE PORCH DECK COLUMNS ARE STACK JOINTED WITH NO STRUCTURAL (BOLTED) LAP JOINT. THE CRITICAL BEAM TO COLUMN STRUCTURAL CONECTION IS DEFICIENT IS THAT THESE JOINTS ARE HELD TOGETHER WITH UNDERSIZED (!/4") STEEL BRACKETS.THE PORCH DECK(S) FLOOR JOISTS HAVE UNDERSIZED (2"X6") BOARDS THAT ARE OVERSPANNED (18") SUPPORTING 3 LEVELS OF DECKS.THE STAIR SYSTEM SUPPORT COLUMNS HAVE DEFICIENT LAP JOINTS (8" LAP W/ 2 BOLTS). ALL BANISTERS ARE WITHOUT AN INTERMEDIATED SUPPORT POST.ALL STRUCTURAL COLUMNS ARE OVERNOTHCED. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. 4843 S MICHIGAN AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR NO ENTRY TO COMPLETE ANNUAL INSPECTION. 4843 S MICHIGAN AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR NO ENTRY TO COMPLETE ANNUAL INSPECTION. 4843 S MICHIGAN AVE PERIODIC FAILED View
PARAPET SOUTH AND EAST ELEVATION -PARAPET WALL SPALLING BRICK AND WASHED OUT MORTAR. 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION- GRADE TO 1ST FLOOR SPALLING BRICK AND WASHED OUT MORTAR. 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR SKYLIGHT FRONT INTERIOR STAIRS 3RD FLOOR SKYLIGHT GLASS PANE CRACKED. 4843 S MICHIGAN AVE PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED FRONT INTERIOR STAIRS 1ST,2ND AND 3RD FLOOR NO EMERGENCY LIGHTS. 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR FLOOR FRONT 1ST FLOOR FOYER TILE FLOOR CRACKED 4843 S MICHIGAN AVE PERIODIC FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE NORTH AND SOUTH ELEVATION-PARPETWALL WASHED OUT MORTAR.NORTH EAST OVERHEAD GARAGE DOOR HEADER SAGGING. 4843 S MICHIGAN AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY REAR GATE LOCKED WITH PADLOCK. 4843 S MICHIGAN AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO BUILDING INTERIOR 4843 S MICHIGAN AVE PERIODIC FAILED View