REPLACE D&H PORCH | REAR PORCH JOISTS BEAMS AND HEADER JOISTS OVER SPANNED NO JOIST HANGERS NO BOLTED CONNECTIONS NO TIE STRAPS AT BEAM TO MASONRY WALL STAIRS WITH UNDERSIZED WEAK STRINGERS TREADS LESS THAN 10' AND WEAK CONNECTIONS AT LANDINGS COLUMNS OVER NOTCHED AND SITTING ON BLOCKS 42' FOUNDATIONS REQUIRE LIGHT GAUGE METAL CONNECTION AT BEAM TO COLUMN PLANS AND PERMITS REQUIRED TO REPLACE DANGEROUS HAZARDOUS PORCH IN REAR FRONT PORCH- STAIR SYSTEM HAS COLLAPSED CENTER MASONRY COLUMN HAS COLLAPSED GUARDRAILS UNDER 42' WITH MISSING PICKETS AND LOOSE COMPONENTS OBTAIN PERMIT ONLY TO REPLACE FRONT PORCH SYSTEM | 7 W 112TH PL | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | MISSING SCREEN WINDOWS AND DOORS ALL ELEVATIONS | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN PANE SOUTH ELEVATION MISSING STORM WINDOWS | 7 W 112TH PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ROTTED WINDOW SASH ALL ELEVATIONS | 7 W 112TH PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ROTTED WINDOW FRAMES ALL ELEVATIONS | 7 W 112TH PL | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | PROVIDE GUARDRAIL 3' HIGH AT REAR AREAWAYS | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | PROVIDE HANDRAIL TO BASEMENT AT REAR AREAWAY | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | REAR AREAWAY WALLS COLLAPSING INWARD WITH LARGE CRACKS | 7 W 112TH PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK SEVERE CRACKS AND UNEVEN CONCRETE | 7 W 112TH PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT INFO IN CONSPICUOUS PLACE | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR EAVES | SOFFIT AND FASCIA ROTTED ALL ELEVATIONS | 7 W 112TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FULL INTERIOR INSPECTION | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | RR-SIDE PORCH SYSTEM MASONRY PIERS LEANING WITH STRESS FRACTURES GUARDRAILS LESS THAN 42' WITH WEAK RAILS AND CONNECTIONS WEAK STRINGERS LOOSE ROTTED TREADS AND RISERS NO BOLTED CONNECTIONS OBTAIN PERMIT ONLY TO REPLACE 1 STORY SIDE PORCH | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | RR-EXTERIOR SIDING LOOSE MISSING PIECES EAST ELEVATION | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | RR-MISSING STORM WINDOWS ALL ELEVATIONS | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | RR-PROVIDE HANDRAIL TO BASEMENT FRONT AREAWAY | 7 W 112TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | RR-ARRANGE INTERIOR INSPECTION | 7 W 112TH PL | COMPLAINT | FAILED | View |
STOP LEAKING WATER | FIRST FLOOR BATHROOM CEILING. (18-29-705.1 THRU 16) (13-168-1480) | 7 W 112TH PL | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | (18-29-106.2) (13-168-070) 1(4-332-010-100) | 7 W 112TH PL | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL - SPALLING BRICKS; LOOSE MORTAR | 7 W 112TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. REAR AND SIDE GATES CHAINED AND PADLOCKED. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | DOWNSPOUT DISCONNECTED NORTH PER 18-29-1101-2-1 | 7 W 112TH PL | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | RR-GUTTERS PLUGGED WITH WEEDS 18-29-1101-2-1 | 7 W 112TH PL | COMPLAINT | FAILED | View |