The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | REAR STAIRS FROM GRADE TO BASEMENT MISSING HANDRAIL. | 1300 N MILWAUKEE AVE | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER'S I.D. SIGN. | 1300 N MILWAUKEE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION-STEP FRACTURES. | 1300 N MILWAUKEE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE, UNVERIFIED OCCUPANCY & DETECTORS. | 1300 N MILWAUKEE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER'S I.D. SIGN. | 1300 N MILWAUKEE AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION-STEP FRACTURES. | 1300 N MILWAUKEE AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE, UNVERIFIED OCCUPANCY & DETECTORS. | 1300 N MILWAUKEE AVE | PERIODIC | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 18-28-106.1 INSPECTION REQUIRED: ARRANGE FOR COMPLETE PERMIT INSPECTION AND OBTAIN PERMIT FOR VENTILATION SYSTEMS WHEN WORK IS COMPLETED | 1300 N MILWAUKEE AVE | COMPLAINT | PASSED | View |
ARRANGE PERMIT INSP. | 1300 N MILWAUKEE AVE | PERMIT | FAILED | View | |
ARRANGE PERMIT INSP. | 1300 N MILWAUKEE AVE | PERMIT | PASSED | View | |
ARRANGE PREMISE INSPECTION | GAINED ENTRY TO AL'S BEEF BUT NOT TO 2ND AND 3RD FLOOR UNITS TO VERIFY COMPLAINT OF ROACH INFESTATION. | 1300 N MILWAUKEE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 1300 N MILWAUKEE AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO ENTRY NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS ANDUNABLE TO VERIFY 3RD FLOOR ROOF LEAK. | 1300 N MILWAUKEE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS FROM GRADE TO BASEMENT MISSING HANDRAIL. | 1300 N MILWAUKEE AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | (VT 6011) 18-28-506 COMMERCIAL KITCHEN GREASE DUCTS AND EXHAUST EQUIPMENT SHALL COMPLY WITH THE REQUIREMENTS SECTION 18-28-506 AND SHALL BE DESIGNED FOR THE TYPE OF COOKING APPLIANCE AND HOOD SERVED | 1300 N MILWAUKEE AVE | COMPLAINT | PASSED | View |