The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OWNER OR LICENSED CONTRACTOR | 4615 N DAMEN AVE | PERIODIC | CLOSED | View | |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2006 THROUGH 2012 | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
SAFE WORKING CONDITIONS | 4633 1/2 COMMERCIAL SPACE- CEILING RADIATORS STEAM VENTS LEAKING AND MAKING NOISE. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | 4633 1/2 COMMERCIAL SPACE- STOCKPILED WITH JUNK AND DEBRIS WITH ONLY SMALL AISLE . FIRE SAFETY HAZARD. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 4633 1/2 COMMERCIAL SPACE- STOCKPILED WITH JUNK AND DEBRIS WITH NO ACCESS TO REAR EXIT OR TOILET FACILITIES . | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | NORTHEAST BASEMENT BOILER ROOM - HOLES IN CEILING , EXPOSED LATH WITH POOR PREVIOUS PATCHES WITH PLYWOOD. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
CHIMNEY | NORTHEAST BASEMENT BOILER ROOM - OPEN JOINT AT BASE OF CHIMNEY WHERE VENT PIPES FOR BOILER AND WATER HEATER ENTER CHIMNEY. NOT SEALED. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | NORTHEAST BASEMENT BOILER ROOM - LARGE WATER HEATER FLUE PIPE SMASHED AND DENTED AT TOP IN CENTER OF RUN. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | NORTHEAST BASEMENT BOILER ROOM - TWO MEN USING BOILER ROOM AS CABINATE AND WOODWORKING SHOP. FIRE AND SAFETY HAZARD . | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REPAIR AREAWAY WALL | SOUTHWEST EXTERIOR AREAWAY CEILING COVERED IN PLYWOOD , NOT FIRE RATED. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTHWEST EXTERIOR AREAWAY - FLAKING MASONRY COATING. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REPAIR ROOF | EIGHT PORCH ROOFS ROTTED JOIST AND DECKING WITH FLAKING PAINT . | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | EIGHT PORCH ROOFS , GUTTERS AND DOWNSPOUTS RUSTED , LEAKING WITH FLAKING PAINT. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | SOUTH CENTER PORCH - MOTOR SCOOTER STORED UNDER WOOD PORCH , FIRE AND SAFETY HAZARD. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
MAINTAIN WINDOW SASH | NORTH , SOUTH AND REAR ELEVATIONS , BASEMENT WINDOWS ROTTED WITH FLAKING PAINT AND PUTTY. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
WORK NOT ALLOWED | REMOVE REAR (EAST ) ELEVATION AT ALLEY ,EIGHT FOOT HIGH CHAINLINK AND IRON YARD FENCE WITH BARBWIRE TOP INSTALLED WITHOUT PLAN OR PERMITS . | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | 4615 1/5 COMMERCIAL SPACE - SOUTH BREAKROOM SOUTH WALL WATER DAMAGED PLASTER. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
EXPOSED WIRING FIXTURES | 4633 1/2 COMMERCIAL SPACE - EXPOSED WIRES AT CEILING FIXTURE. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
CORRODED CONDUIT & EQUIP | EIGHT EXTERIOR PORCHES - CONDUITS AND BOXES LOOSE AND SEVERELY RUSTED ALL ELEVATIONS AND FLOORS. LOOSE LIGHT FIXTURES WITH EXPOSED WIRES. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ( REAR ) SERVICEWALK , BROKEN SHIFTED CONCRETE WITH STANDING WATER. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EIGHT THREE STORY WOOD PORCHES , ALL WITH SIMILAR DEFECTS AND HARDWARE INSTALLED WITHOUT PERMITS. ALL PORCHES REQUIRE UPDATES WITH PROPER PERMITS AND PLANS OBTAINED . PORCH PERMIT APPLICATION #100105412 APPLIED FOR 4-3-2006 VOIDED AND NOT OBTAINED.PORCH FOUNDATIONS OF UNKNOWN STATUS WITH SOME UPRIGHTS BOXED IN CONCRETE. UPRIGHTS TWISTED AND SLIPPING OFF CONCRETE BASES , DOUBLE NOTCHED WITH SPLICE JOINTS TOO SHORT AND OF IMPROPER DESIGN . BEAMS OVERSPANNED AND PULLING OUT OF UPRIGHT FIRECUTS WITH LARGE OPEN GAPS AND ONLY NAILED HOLDING CONNECTIONS . JOISTED OVERPANNED WITH JOIST HANGERS AND HARDWARE SEVERELY RUSTED AND OF UNKNOWN STATUS. STAIR STINGERS NO HEADER SUPPORT WITH STAIR TREADS ONLY 9 INCHES WIDE. GUARDRAILS ON STAIRS AND DECKS UNDERSIZED , WITH ONLY NAILS HOLDING TO BRICK WALL. OVERSPANNED SECTIONS WITHOUT INTERMEDIATE NEWEL POST . | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING /MOST APTS. - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT ALL INTERIOR STAIRWAYS. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
CHIMNEY | NORTH ELEVATION /CHIMNEY - SPALLED BRICKS, WITH WASHED OUT MORTAR. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH AND EAST ELEVATIONS /EXTERIOR WALL - SPALLED BRICKS, WITH WASHED OUT MORTAR. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |
REMOVE CHIMNEY DEBRIS | 4615 N DAMEN AVE | PERIODIC | CLOSED | View | |
REPAIR INTERIOR WALLS/CEILING | 4633 1/2 COMMERCIAL SPACE- WATER DAMAGED CEILING PLASTER. | 4615 N DAMEN AVE | PERIODIC | FAILED | View |