The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ACCESS TO ROOF | 1340 W 87TH ST | PERIODIC | FAILED | View | |
ARRANGE FOR INSPECTION | CALL INSPECTOR MARK HOUTSMA(312)743-3562 | 1340 W 87TH ST | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION 2ND FLOOR BROKEN WINDOW PANES. | 1340 W 87TH ST | COMPLAINT | CLOSED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION WINDOW SILLS HAVE WASHED OUT MORTAR JOINTS. | 1340 W 87TH ST | COMPLAINT | CLOSED | View |
REPAIR COPING | SOUTH ELEVATION COPING STONES HAVE WASHED OUT MORTAR JOINTS.WEST ELEVATION COPING TILES CRACKED AND BROKEN. | 1340 W 87TH ST | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | BROKEN GARAGE DOOR. WASHED OUT AND MISSING MORTAR JOINTS AT ALL ELEVATIONS. STEP FRACTURES AT ALL ELEVATIONS. PERMIT REQUIRED FOR MASONRY REPAIRS TO DETACHED GARAGE AND TWO STORY MASONRY BUILDING. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | LEANING SECTION OF WOOD FENCE AT NORTH ELEVATION. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ROTTING WINDOW SASHES AT SOUTH, WEST AND NORTH ELEVATIONS AT MULTIPLE LOCATIONS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | STEP FRACTURE AT SOUTH AND WEST ELEVATIONS, MULTIPLE LOCATIONS. CHIPPED STONE AT SOUTH ELEVATION FIRST FLOOR SILL. LOOSE AND MISSING MORTAR JOINTS AT MULTIPLE LOCATIONS OF SOUTH AND WEST ELEVATIONS. PERMIT REQUIRED FOR MASONRY REPAIRS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | HIGH WEEDS AT NORTH ELEVATION ADJACENT TO MASONRY GARAGE. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW PANE AT SECOND FLOOR OF SOUTH ELEVATION. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO GAIN INTERIOR ACCESS TO VERIFY COMPLAINT SR#21-00762567 OF INADEQUATE EGRESS REQUIRING PATRONS TO EXIT BY JUMPING OVER FENCE AT ALLEY. UNABLE TO VERIFY INTERIOR DETECTORS, CONDITIONS AND OCCUPANCY. CALL 312-545-1376 TO SCHEDULE INTERIOR INSPECTION. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | WEST ELEVATION / EXTERIOR BASEMENT STAIRS - DEBRIS AT LANDING. | 1340 W 87TH ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / MULTIPLE LOCATIONS - WASHED OUT MORTAR JOINTS, STEP FRACTURES. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO ENTRY. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. UNABLE TO VERIFY COMPLAINT OF OPEN SEWER PIPING AND BACTERIAL GROWTH IN THE BASEMENT. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION / 2ND FLOOR - BROKEN WINDOW PANES. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | SOUTH AND WEST ELEVATIONS / 2ND FLOOR - ROTTING WINDOW SASHES AT MULTIPLE LOCATIONS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH AND WEST ELEVATIONS / 2ND FLOOR - ROTTING WINDOW FRAMES AT MULTIPLE LOCATIONS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | SOUTH AND WEST ELEVATIONS / 2ND FLOOR - MISSING WINDOW SCREENS AT MULTIPLE LOCATIONS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | SOUTH AND WEST ELEVATIONS / 2ND FLOOR - TORN WINDOW SCREENS AT MULTIPLE LOCATIONS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST ELEVATION / FENCE - LEANING WITH BROKEN AND MISSING SECTIONS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | NORTH ELEVATION / ADJACENT TO PUBLIC ALLEY - BARB WIRE AT 6 FOOT 4 INCHES ABOVE ALLEY GRADE. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR COPING | WEST ELEVATION / TILE COPING - BROKEN TILE. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PARAPET | EAST ELEVATION / NORTHEAST CORNER - OUT OF PLUMB AND LEANING OVER ROOF. WASHED OUT MORTAR JOINTS, SPALLING BRICKS. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH ELEVATION / GATE ADJACENT TO ALLEY - CHAINED AND PADLOCKED.L | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION / STAIRS FROM 2ND FLOOR TO GRADE - 4X4 POSTS ON CONCRETE BLOCKS AND CONCRETE SLAB WITH NO FOUNDATION. 12 INCH LAP JOINTS AT POSTS ANCHORED WITH NAILS ONLY. LOOSE AND PULLING RAILING SYSTEM THROUGHOUT. UPPER AND LOWER END OF STRINGER INADEQUATELY ANCHORED WITH NAILS ONLY. ROTTING TREADS, MULTIPLE LOCATIONS. PLANS AND PERMIT REQUIRED FOR EXTERIOR STAIR REPAIRWEST ELEVATION / STAIRS FROM GRADE TO BASEMENT - MISSING HANDRAIL. | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | WEST ELEVATION / EXTERIOR BASEMENT STAIR - FRACTURED CONCRETE AT RETAINING WALL WITH SECTIONS MISSING. | 1340 W 87TH ST | COMPLAINT | CLOSED | View |
REMOVE AND REPLACE***** | REPAIR OR REMOVED DAMAGED, BROKEN UNSECURED AWNING. 18-27-110.12 SIGN READS' GOLDEN GIRL BAR & LOUNGE APPROXIMATE SIZE' 25'X 3' PERMIT #ES 2960991 | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PROVIDE SERVICE RATED DISCONNECTS IN BASEMENT AREA 14E-2-230.70 | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
PROVIDE A WATER MAIN GROUND CONDUIT, CONDUCTOR TO WITHIN 5' OF WATER METER OR VALVE NO WATER GROUND 14E-2-250.68C1 DANGEROUS AND DANGEROUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR WALL | THE NORTH EXTERIOR MASONRY WALL IS PARKING 14X-3-303.1.1 | 1340 W 87TH ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSE PLUMBING CONTRACTOR FOR ALL PLUMBING REPAIRS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE SERVICE HEAD AT SERVICE RISER, WIRES HANGING ON END EDGE OF CONDUIT 14E-2-230.54 DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
PRV DISCHARGE PIPE FROM PRV | BASEMENT MISSING DISCHARGE FOR WATER HEATER | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PARAPET | THE PARAPET AT THE NORTHEAST ELEVATION ID LEANING INWARD AND IN DANGER OF COLLAPSE 14X-3-303.6 DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | REMOVE JUNK AND DEBRIS IN 1ST FLOOR FURNACE ROOM 14X-1-103 FIRE HAZARD DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT BEFORE ANY REPAIR ARE MADE | 1340 W 87TH ST | COMPLAINT | FAILED | View |
MULTIPLE CONDUCTOR TERM | REMOVE DOUBLE LUGGING IN DISCONNECT IN BASEMENT AREA | 1340 W 87TH ST | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCE FOR ELECTRICAL PANEL IN 1ST FLOOR BAR AREA | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PROVIDE OPEN FRONT TOILET SEAT | 1ST FLOOR NO OPEN FRONT SEAT | 1340 W 87TH ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT THE BASEMENT, 1ST FLOOR AREAS DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View |
CIRCUIT 1 UNIT ONLY | PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE COMMON AREAS, BASEMENT AREAS AND GARAGE | 1340 W 87TH ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | PROVIDE GROUND CONTINUITY FOR CORD TO EXIT SIGN AT DOOR ENTRANCE AREA AND ARMOURED CABLE ABOVE DROP CEILING AREA, BASEMENT AREAS DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR WOODEN STAIR SYSTEM 4X4 COLUMNS INADEQUATE AND INCORRECT LAP JOINTS RESTING ON CONCRETE POURED BLOCKS/NO FOOTINGS, INCORRECT RISER HEIGHTS BROKEN AND MISSING PICKETS LOOSE HANDRAILS 14X-3-303.1.1 | 1340 W 87TH ST | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 14A-4-404.6 . | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
PRV FLUE FOR HOT WATER HEATER | BASEMENT FLUE PIPE FOR WATER HEATER BACK PITCHED DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PROVIDE | 1ST FLOOR NEED BACK FLOW PROTECTION FOR ICE MAKER 18-29-608.1 | 1340 W 87TH ST | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | 1ST FLOOR REMOVE UNAPPROVED PVC DRAIN PIPE AT REAR SINK AND THROUGHOUT PREMISES | 1340 W 87TH ST | COMPLAINT | FAILED | View |
SUPPLEMENTAL GROUND | PROVIDE SUPPLEMENTAL GROUND FOR METER BANK AREA DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | NORTH ELEVATION BARBED WIRE OVER FENCE. | 1340 W 87TH ST | COMPLAINT | CLOSED | View |
FIRE EXTNGSHR REQ, NONRESDNTL | FIRE EXTINGUISHER NOT HUNG BY FRONT ENTRY DOOR 14X-5-504.5 DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
MIXED OCCUPANCY SEPARATION | EXPOSED WOOD LATH AND JOISTS ABOVE 1ST FLOOR CEILING GRID (BELOW 2ND FLOOR RESIDENTIAL UNITS) FIRE SEPARATION IS REQUIRED (DRYWALL TYPE X FIRECODE 14B-5-508 DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | THERE A LARGE SECTIONS OF PLASTER/DRYWALL MISSING FROM BASEMENT CEILING, FIRE SEPARATION IS REQUIRED (DRYWALL TYPE X FIRECODE) 14B-6-605.4 DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR AT BASEMENT AND 1ST FLOOR 14X-5-504.8 DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE AT BASEMENT AND 1ST FLOOR 14X-5-504.9 DANGEROUS AND HAZARDOUS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | THERE IS LARGE AMOUNTS OF BLACK ORGANIC MOLD LIKE SUBSTANCE IN THE BASEMENT 14X-1-103 UNSANITARY | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMITS REQUIRED FOR THE REAR WOODEN STAIR SYSTEM 14A-4-401.1 | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE UNAPPROVED FLEXIBLE WATER SUPPLY LINES AT TOILETS LAVATORIES AND SINKS AND HARD PIPE WITH COPPER SUPPLY LINE AT ALL LOCATIONS AND THROUGHOUT PREMISE | 1340 W 87TH ST | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES WITH EXPOSE WIRING THROUGH OUT THE BASEMENT AREA, ABOVE THE 1ST FLOOR DROP CEILING AREA, BAR COUNTER TOP AREA DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | PROVIDE MAINTENANCE FOR EM LIGHTS AND EXIT SIGNS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE ALL DEFECTIVE AND EXCESSIVE USE OF ARMOURED CABLE THROUGH OUT THE BASEMENT, 1ST FLOOR BAR COUNTER TOP AREA AND ABOVE DROP CEILING AREA (POOR SHAPE DUE TO DETERIORATION POSSIBLE DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SECURE ALL CONDUIT RUNS JUNCTION BOXES THROUGH OUT THE BASEMENT 1ST FLOOR AREA AND ABOVE DROP CEILING AREAS DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | PROVIDE WEATHERPROOF BOXES FITTINGS DEVICES AND APPROVED RACEWAY FOR ALL EXTERIOR AREAS OF BUILDING | 1340 W 87TH ST | COMPLAINT | FAILED | View |
PANEL SCHEDULES | PROVIDE PANEL SCHEDULES FOR ALL PANELS IN BASEMENT AND 1ST FLOOR AREAS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | REPLACE ALL RUSTED CORRODED BOXES,FITTINGS AND APPROVED RACEWAYS AT BASEMENT AREAS AND EXTERIOR AREA OF BUILDING | 1340 W 87TH ST | COMPLAINT | FAILED | View |
ABANDONED EQUIPMENT | REMOVE ALL ABANDONED RACEWAY BOXES CONDUIT RUNS AND ELECTRICAL EQUIPMENT THROUGH OUT THE BASEMENT AND 1ST FLOOR AREAS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
INSTALL GFCI'S | PROVIDE GFCI PROTECTION FOR ALL BAR COUNTER TOP AREA AND BASEMENT AREAS | 1340 W 87TH ST | COMPLAINT | FAILED | View |
DETERIORATED CONDUCTORS | REPLACE ALL DEFECTIVE AND DETERIORATED WIRING THROUGH OUT THE BASEMENT AREA POOR SHAPE | 1340 W 87TH ST | COMPLAINT | FAILED | View |
CEILING SUPPORT WIRE AND CEILING GRIDS SHALL NOT BE USED FOR SUPPORT PROPERLY SUPPORT ALL CAN LITES CONDUIT RUNS, AND JUNCTION BOXES THROUGH OUT THE DROP CEILING AREAS 14E-3-300.11 DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
JUNCTION BOXES NOT PROPERLY SIZE IN BASEMENT PANEL AREA AND UNDER BAR COUNTERTOP AREAS 14E-3-314.16 | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
PROPERLY BOND ALL ELECTRICAL PANELS, DISCONNECTS IN BASEMENT AREA SO AS TO ESTABLISH AN EFFECT PATH FOR FAULT CURRENT 14E-2-250.4 A3 DANGEROUS AND HAZARDOUS CONDITION | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
PROVIDE PROPER TYPE COVERS FOR PANEL, JUNCTION BOXES COVERED IN SHEET METAL MATERIAL NOT APPROVE FOR USE IN BASEMENT AREA 14E-1-110.3 | 1340 W 87TH ST | COMPLAINT | FAILED | View | |
ARRANGE PREMISE INSPECTION | NEED ENTIRE CEILING REMOVE SO INSPECTOR IS GRANTED FULL ACCESS FOR INSPECTION | 1340 W 87TH ST | COMPLAINT | FAILED | View |