The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY CAPPING | CHIMNEY CAP MISSING | 4160 W NELSON ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | OPEN WIRING VARIOUS AREAS REAR BASEMENT. OPEN WIRE RUNNING THROUGH WALL AND CEILING AT REAR BASEMENT. REMOVE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 4160 W NELSON ST | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | NO VISIBLE WATER GROUND. ENSURE SERVICE GROUNDED INAPPROVED MANNER. DANGEROUS AND HAZARDOUS | 4160 W NELSON ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | OPEN AIR SPLICES BETWEEN FLEXIBLE METAL CONDUIT REAR BASEMENT. ENSURE GROUND CONTINUUITY WHERE REQUIRED THROUGHOUT. DANGEROUS AND HAZARDOUS | 4160 W NELSON ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | DAMAGED SWITCHES AND RECEPTACLES REAR BASEMENT AREA. REPLACE WHERE REQUIRED. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
ARMORED CABLE | UNAPPROVED, UNSUPPORTED, ARMORED CABLE VARIOUS AREAS REAR BASEMENT AREA. INSTALL IN APPROVED MANNER WHERE REQUIRED.... | 4160 W NELSON ST | COMPLAINT | FAILED | View |
PANEL SCHEDULES | INSUFFICIENT PANEL SCHEDULES. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | 4160 W NELSON ST | COMPLAINT | FAILED | View | |
DEFECTIVE SERVICE | RUSTED RISER SUPPORTS. SEPARATE CIRCUITRY AND INSTALL COMMON METER. SERIVCE MODIFIED FROM ORIGINAL CONDITION. ENSURE SERVICE INSTALLED IN APPROVED MANNER. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | REFUSED ENTRY TO DWELLING UNITS BY OWNER. ENTRY WAS MADE TO BASEMENT REAR ENCLOSED PORCH ONLY. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH WITH WOOD STUDDING. 1 HR FIRE SEPARATION IS REQUIRED | 4160 W NELSON ST | COMPLAINT | FAILED | View |
PARAPET | WEST PARAPET REQUIRES SOME TUCKPOINTING, APPEARS TO HAVE LOOSE/ERODED MORTAR JOINTS | 4160 W NELSON ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | HEADER FOR GARAGE OVER-HEAD DOOR APPEARS TO BE SAGGING. OBSERVED FROM ALLEY | 4160 W NELSON ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INSTALLED IN THE BASEMENT WITH OUT A PERMIT. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. BASEMENT APARTMENT NOT ORIGINAL CONSTRUCTION. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | HIGH WEEDS AT FRONT YARD | 4160 W NELSON ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE ACCESS TO INSPECT CONDITION OF ELECTRICAL SYSTEM IN TYPICAL SPACES. (14A-5-505.2) | 4160 W NELSON ST | COMPLAINT | FAILED | View |
CONNCT PLUMBING SYSTEM TO SEWR | PVC PIPE IS DISCHARGING WASTE WATER INTO BACK YARD GRASS AREA. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
INSTALL GFCI'S | INSTALL GFCI PROTECTION KITCHEN, BATH, BASEMENT, LAUNDRY, EXTERIOR, GARAGE. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL OPERABLE ILLUMINATION AT ALL EXTERIOR ENTRIES, GARAGE, INTERIOR STAIRS, BASEMENT. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | FOUL ODOR INSIDE AND AROUND EXTERIOR OF PREMISES FROM DISCHARGED WATER. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | 4160 W NELSON ST | COMPLAINT | FAILED | View | |
OBTAIN PERMIT TO CORRECT VIOLATIONS. (14A-4-404.6) | 4160 W NELSON ST | COMPLAINT | FAILED | View | |
DETERIORATED CONDUCTORS | DETERIORATED CLOTH WIRING, DAMAGED WIRING VISIBLE AT OPEN BOXES REAR BASEMENT AND STAIR AREA. REPLACE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 4160 W NELSON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ACCESS ONLY TO REAR EXTERIOR AND REAR ENCLOSED PORCH. | 4160 W NELSON ST | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN BOXES VARIOS AREAS REAR BASEMENT AND REAR STAIRS. CLOSE WHERE REQUIRED. DANGEROUS AND HAZARDOUS | 4160 W NELSON ST | COMPLAINT | FAILED | View |