| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| OPEN TYPE VIOLATION | STOP ALL WORK UNTIL PERMIT IS OBTAINED SEC (13-12-080) AND (13-32-035) | 2154 W NORTH AVE | COMPLAINT | FAILED | View |
| REPAIR EAVES | EAVES - RUSTING WITH HOLE | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, APARTMENTS, INTERIOR STAIRWELL, BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS INSIDE 1ST FLOOR STORE AT SOUTH WEST ON 1ST FLOOR | 2154 W NORTH AVE | COMPLAINT | FAILED | View |
| POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| FILE BLDG REGISTRATION | NO BUILDING REGISTRATION FROM 1990 THROUGH 2012. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| REPAIR PORCH SYSTEM | REAR 3 STORY PORCH, 6X6 COLUMNS REST ON BUCKLING FOUNDATION WALL, RECENTLY REPLACED 6X6 COLUMNS AND BEAMS INSTALLED AS BUTT JOINTS, 6X6 COLUMNS NOTCHED AT BEAM CONNECTIONS, CONNECTIONS NAILED ONLY. 4X6 BEAM SUPPORTING LANDINGS OVER SPAND, STRINGER CONNECTIONS NAILED ONLY. GUARD RAILS AT 34 INCHES IN HEIGHT ONLY, MISSING CENTER SUPPORTS,CONNECTIONS TO COLUMNS AND MASONARY WALLS NAILED ONLY.PLANS AND PERMIT REQUIRED FOR REPLACEMENT. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| REPAIR DEFECTIVE FOUNDATION | FOUNDATION WALL SUPPORTING 3 STORY PORCH, SEVERLEY BUCKLING AND SECTIONS CRACKED. PLANS AND PERMIT REQUIRED FOR REPLACEMENT. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| REPAIR CORNICE | SOUTH AND WEST ELEVATIONS, METAL CORNICE SEVERLEY RUSTING. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| REPAIR PORCH SYSTEM | REAR PORCH - 2X8 JOISTS SPAN 11'-6"; 6X6 COLUMNS STACKED AND TOENAILED; BEAMS TOENAILED TO COLUMNS; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; SPINDLES MISSING AT HANDRAILS FROM GRADE TO 3RD FLOOR; HANDRAIL PULLING AWAY FROM 6X6 COLUMN BETWEEN 1ST AND 2ND FLOOR. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 2154 W NORTH AVE | PERIODIC | FAILED | View |
| FILE BLDG REGISTRATION | NOT REGISTERED 2000-2010 | 2154 W NORTH AVE | PERIODIC | FAILED | View |