Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST I.D. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH STRUCTURE WITH THE FOLLOWING DEFECTS,1) 6X6 COLUMN BUTT JOINT CONSTRUCTION.2) 4X4 COLUMN BUTT JOINT CONSTRUCTION 3) 4X4 COLUMN SUPPORTING STRINGERS AND WINDERS OVER SPAN.4) 6X 6 LOOK-OUTS TO 6X6 COLUMN CONNECTION POINT BELOW BUTT JOINT SECOND FLOOR INTERMEDIATE LEVEL (EAST COLUMN).5) STRINGER CONNECTIONS NAILED TO FLOATING 4X4 POST.6) WINDERS IMPROPERLY CUT LESS THAN 4AND ONE HALF INCHES OF LUMBER.7) WINDER CONNECTIONS TO COLUMN BUTTED AND NAILED.8) RISERS ON WINDERS SEPARATING FROM CUT RISERS AND 4X4 SUPPORT POST.9) BEAM TO COLUMN CONNECTIONS NOTCHED AND NAILED.10) RECENTLY INSTALLED 2X10 JOIST NOTCHED OVER 6X6 LOOK-OUT AND CRACKED.11) FOOTINGS FOR EAST ELEVATION 6X6 COLUMNS POURED CONCRETE BLOCK ON TOP OF RETAINING WALL.12) ALL TREADS AND RISERS LOOSE WITH NAILS STICKING OUT.13) PLANS AND PERMITS REQUIRED FOR REPAIRS OR REPLACEMENT. | 2740 W WINNEMAC AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH ELEVATION, PARAPET - FRACTURED BRICK WITH OPEN MORTAR JOINTS. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | SOUTH ELEVATION, 1ST AND 2ND FLOORS - LINTELS RUSTING. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION, EXTERIOR WALL - WASHED OUT MORTAR. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION, REAR 3 STORY OPEN WOOD PORCH - MULTIPLE STAIR TREADS LOOSE. WINDING STAIR, TOE NAIL CONNECTIONS PULLING OUT. 1ST FLOOR STAIR RAILING AT GRADE LOOSE. RAILING AT 2ND FLOOR EAST WINDING STAIR LOOSE. 3RD FLOOR DECK RAILING LOOSE. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | NORTH ELEVATION, GARAGE - LINTEL OVER DOOR ROTTEN AND SAGGING. GARAGE WINDOW FRAMES ROTTING. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR UNIT DINING ROOM - CEILING AND WALLS WATER DAMAGED. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 3RD FLOOR, FRONT INTERIOR STAIRS - MISSING SMOKE DETECTOR AT TOP OF STAIRWELL. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE TO BASEMENT, 2ND AND 3RD FLOORS. - UNVERIFIED DETECTORS AND CONDITIONS. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR CORNICE | WEST ELEVATION, CORNICE - CRAKCED. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BASEMENT STAIRS WITH NO HAND RAIL. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | 1ST FLOOR UNIT HALWAY FLOOR - WEAK. | 2740 W WINNEMAC AVE | PERIODIC | FAILED | View |