Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
EXPOSED WIRING | SOUTHEAST PORCH AT GRADE - 6 ELECTRICAL WIRES - LOOSE - NOT IN CONDUIT - FIRE HAZARD. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2011. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | NORTH AND EAST STONE WINDOW SILLS - WASHED OUT MORTAR. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ENTRY DOOR - BROKEN AND MISSING GLASS PANE . | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | EAST ENTRY DOOR - DOOR KNOB - BROKEN. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTHWEST BASEMENT STAIRWAY GRADE TO BASEMENT AT GRADE - GUARDRAILS - '' LADDER '' TYPE -ONLY 38'' HIGH WITH 14'' TO 17'' BETWEEN HORIZONTAL TIES. SOUTHEAST BASEMENT STAIRWAY - GRADE TO BASEMENT AT GRADE - MISSING GUARDRAIL SECTION. " LADDER " TYPE GUARDRAILS WITH 20'' BETWEEN HORIZONTAL TIES . NORTHEAST BASEMENT STAIRWAY - GRADE TO BASEMENT AT GRADE - GUARDRAIL - MISSING. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH 5' METAL FENCE - LOOSE , BENT , AND BROKEN TOP RAILS. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH WALL - WASHED OUT MORTAR WITH SPALLING BRICKS. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AND EAST AT 1ST AND 2ND - BROKEN WINDOW PANES. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH AND EAST WINDOW FRAMES - ROTTED WITH PEELING PAINT. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH PORCHES - APARTMENT DOORS WITH BURGLAR BARS. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
PARAPET | SOUTH PARAPET - WASHED OUT MORTAR. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | SOUTHEAST PORCH AT BASEMENT - LOOSE PIECES OF LUMBER , SOME LUMBER STACKED UP AGAINST RETAINING WALL. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | SOUTHEAST CONCRETE CATCH BASIN - BROKEN AND CRACKED CONCRETE COLLAR. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | SOUTHWEST BASEMENT RETAINING WALL - FRACTURED , BROKEN , BUCKLED , AND SHIFTING CONCRETE WITH TOP OF WALL LEANING TOWARDS BUILDING. SOUTHEAST BASEMENT RETAINING WALL - HOLES IN CONCRETE WITH MISSING SECTIONS OF CONCRETE. PERMIT REQUIRED TO REPAIR BOTH BASEMENT RETAINING WALLS. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH 2 - TWO STORY OPEN WOOD PORCHES- COLUMNS ERECTED ON CONCRETE BASES WITH CONCRETE POURED AROUND COLUMNS [ CRACKING ] - FOUNDATION STATUS UNKNOWN. TWISTED AND SPLIT COLUMNS. SOUTHEAST PORCH -LEDGER BEAMS ONLY NAILED TO BUILDING. DECK JOISTS ONLY NAILED TO LEDGER BEAMS. BOTH PORCHES : BEAMS TO MASONRY - MISSING CONNECTORS. UNDER SIZED 2 X 8 DECK JOISTS SPANNED AT 13' 6''. BEAMS ONLY NAILED TO COLUMNS . ROTTED STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. SOME STRINGER SECTIONS LOOSE AND PULLING AWAY FROM COLUMNS. OUTER LANDINGS WEAK AND SWAYING EXCESSIVELY - VERY UNSTABLE. SOME DECKING - LOOSE AND PULLING AWAY - TRIP HAZARD. SPLIT AND ROTTED TREADS. SOME GUARDRAIL SECTIONS ONLY 40'' HIGH , LOOSE AND PULLING AWAY FROM BUILDING - HAZARDOUS. HANDRAILS - VERY LOOSE WITH LOOSE AND MISSING PICKETS. MANY PORCH MEMBERS ARE WEAK AND ROTTED . PLANS AND PERMIT REQUIRED TO REPAIR BOTH PORCHES. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS OR VERIFY COMPLAINT OF KICHEN CEILING COLLAPSING. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTHWEST BASEMENT SERVICE WALK - BUCKLED , CRACKED , BROKEN , AND UNEVEN SURFACES - TRIP HAZARD. EAST SERVICE WALK - BROKEN , CRACKED , AND MISSING CONCRETE - TRIP HAZARD. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | SOUTH PORCH ROOFS - WOOD SHEATHING - ROTTED WITH HOLES AND FLAKING PAINT. | 9100 S DAUPHIN AVE | COMPLAINT | FAILED | View |