The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| STOP/REMOVE NUISANCE | REAR PORCH AT BASEMENT UNDER 1ST FLOOR DECK - STORING BBQ GRILL. | 8721 S ABERDEEN ST | COMPLAINT | FAILED | View |
| REPAIR INTERIOR WALLS/CEILING | APT. - 1 / TENANT EMAILED PICTURES / WALLS AND CEILINGS IN KITCHEN AND BEDROOM CLOSET - WATER DAMAGE WITH LOOSE AND MISSING PLASTER. | 8721 S ABERDEEN ST | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | EAST ELEVATION / 2 STORY WOOD PORCH / STAIR TREADS, DECKING AND TOP RAILS - ROTTING WOOD. | 8721 S ABERDEEN ST | COMPLAINT | FAILED | View |
| MAINTAIN WINDOW | NORTH AND SOUTH ELEVATIONS AT 1ST FLOOR / WINDOW FRAMES - EXPOSED WOOD WITH FLAKING PAINT. | 8721 S ABERDEEN ST | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | SOUTH ELEVATION / EXTERIOR WALL - WASHED OUT MORTAR. | 8721 S ABERDEEN ST | COMPLAINT | FAILED | View |
| PARAPET | NORTH AND SOUTH ELEVATIONS / PARAPETS - SPALLING MASONRY WITH WASHED OUT MORTAR. | 8721 S ABERDEEN ST | COMPLAINT | FAILED | View |
| 1-HR HEATING PLANT ENCLOSURE | BASEMENT FURNACE ROOM ENCLOSED WITH 1/4 INCH WOOD PANELING. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| OBSTRUCTIONS IN EXIT WAY | 1ST AND 2ND FLOOR REAR EXIT ,STORM DOORS, DOUBLE KEYED LOCKS. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| FIRE EXTNGSHR RECHARGE & TAG | BASEMENT CHILD DAY CARE CENTER,FIRE EXTINGUISHERS MISSING TAGS. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| PARAPET | SOUTH AND NORTH PARAPET WALLS WASHED OUT MORTAR,WEST PARAPET FRACTURED MASONRY WITH WALL LEANING FORWARD.MASONRY PERMIT REQUIRED. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| REPAIR PORCH SYSTEM | EAST ELEVATION,REAR EXTERIOR PORCH,6 BY 6 COLUMNS SET ON SIDE WALK.LEDGER IS 2 BY 8 ,FACE NAILED ONLY.JOISTS ARE 2 BY 8 FACE NAILED TO LEDGER AND PULLING AWAY FROM RIM JOIST.BEAMS ARE 6 BY 6 TOE NAILED AT COLUMN NOTCH WITH LIGHT GAGE METAL BANDING AND PULLING APART.COLUMNS ARE BOWED AND TWISTED AT ROOF BEAM.RAILS ARE 36 INCHES HIGH LOOSE AND PULLING,TOP AND BOTTOM RAILS ARE TOE NAILED TO SUPPORTS AND END SUPPORTS ARE MASONRY NAILED TO BRICK WALL.STAIR STRINGERS ARE FACE NAILED AT TOP CONNECTION,TREADS ARE SPLITTING WITH SOME TREADS LOOSE.DECKING BOARDS ARE SPLITTING.PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| REPAIR / REBUILD SHED | EAST ELEVATION REAR YARD,WOODEN LEAN-TO WITH ROTTED COLUMNS,ROTTED ROOF JOISTS AND ROOF SHEETING. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| LIGHT AND VENT | BASEMENT WINDOWS ARE GLASS BLOCK. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| PARTITIONS, N/L/B - BASEMENT | BASEMENT CHILD DAY CARE CENTER,ALL WALLS ARE 1/4 INCH WOOD PANELING. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| CEILING HEIGHT - 7' - BASEMENT | BASEMENT DROPED CEILING HEIGHT IS 6' 2" | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| POST OWNER/MANAGERS NAME/# | BULIDING NO OWNERS I D SIGN POSTED. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |
| WORK NOT ALLOWED | OBTAIN PERMIT TO REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRICAL ) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 8721 S ABERDEEN ST | COMPLAINT | PASSED | View |