The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FLAKY INTERIOR PAINT | EXTERIOR WOOD WORKS FLAKING PAINTS. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BLDG: 3-STORY WOODEN PORCH SYSTEM: ALL LEVELS, UNDERSIZED 2X8 FLOOR JOIST USED OVER 10' LONG SPANS. 1ST FLOOR 6X6 BEAMS ROTTED AT COLUMN CONNECTION JOINTS. ALL COLUMNS BUTT JOINTED AND TOE NAILED. COLUMNS OUT OF PLUMB AND SITTING ON SIDEWALKS, CONCRETE BLOCKS AND RETAINING WALLS WITHOUT BASE - FOUNDATION STATUS UNKNOWN. UNDERSIZED 4X4 COLUMN SPANS 3 FLOORS WITHOUT FOUNDATION BASE. STRINGERS MISSING BOLTS AT COLUMN CONNECTIONS POINT. GUARDRAIL SECTIONS ARE ONLY 32" HIGH. DECKS ARE WEAK WITH ROTTING PLYWOOD BOARDS ON TOP.TREADS, RISERS AND RAILINGS ROTTED AND WORN OUT. FLOOR JOIST AT 2 ROTTED. FULL PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR BLDG: 2-STORY WOODEN PORCH SYSTEM: 4X4 COLUMNS SITTING ON 1ST FLOOR PLYWOOD BOARDS - NO FOUNDATION FOOTINGS. UNDERSIZED 2X6 FLOOR JOISTS SPANING 18' LONG AND OVERSPACED 24" WIDE APART. GUARDRAIL SECTIONS ONLY 32" HIGH AND SPANS 12' LONG. ALL LANDING JOISTS ARE TOE NAILED TO HEADER JOISTS. STRINGER TO COLUMN CONNECTIONS MISSING BOLTS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG.: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. MISSING OWNER'S I.D. SIGN. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | PORCH # 1, - 3 STORY REAR PORCH MAIN HOUSE, - UNKNOWN FOOTINGS,- COLUMNS ARE OUT OF PLUMB, BOWING AND TWISTING, COLUMNS HAVE INADEQUATE HALF - LAP JOINTS, JOINT IS A STRAIGHT CUT, - FASTENED WITH NAILS ONLY,- 6X6 AND 4X4 COLUMNS AND BEAMS MISSING STEEL ANGLES OR STEEL STRAPS, UNDERSIZE LUMBER THROUGHOUT THE ENTIRE PORCH WITH 2X6 FLOOR JOIST, - ALL CRITICAL CONNECTIONS ARE ONLY NAIL THROUGHOUT ENTIRE PORCH, ALL HANDRAILS ARE WEAK AND DO NOT MEET CBC, - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, ALL STRINGERS - WEAK. GUARD RAILS ARE WEAK 30" TO 32" IN HEIGHT. PLANS AND PERMITS ARE REQUIRED TO REPLACE THIS PORCH.PORCH # 2 FOR COACH HOUSE, -UNKNOWN FOOTINGS,- PORCH IS PULLING AWAY FROM THE BUILDING, 6X6 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS FASTENED WITH NAILS ONLY, THE HALF-LAP JOINT IS A STRAIGHT CUT, 2X6 FLOOR JOIST SPAN 13', - BEAM AND COLUMN CONNECTIONS ARE MISSING STEEL ANGLES / BRACKETS THROUGHOUT ENTIRE PORCH, - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER JOIST, - HAND RAILS MISSING FALLING PROTECTION AT ALL FLOORS, GURAD RAILS ARE LESS THEN 42" IN HEIGHT, WEAK WITH LADDER EFFECT THROUGOUT ENTIRE PORCH, - LEDGER BOARDS NOT ATTACHED TO MASONRY, FIRE CUTS ARE BEARING LESS THEN 2" WITH TWO NAILS ONLY, - PLANS AND PERMITS ARE REQUIRED TO REPLACE EXTERIOR PORCH. BOTH PORCH(S) NEED TO BE REPLACE. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS OCCUPANCY AND CONDITIONS. UNABLE TO PERFORM INTERIOR 2015 ANNUAL INSPECTION. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BLDG. NOT REGISTERED FROM 1990 - 2010. | 3041 N SHEFFIELD AVE | PERIODIC | FAILED | View |