Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
RAT STOP AROUND EXTERIOR | EXTERIOR NORTH ELEVATION SIDES OF BUILDING AT GRADE OPENINGS. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
RAT PROOF OPENINGS | INTERIOR BUILDING ALL FLOORS BATHROOM, KITCHEN, AND FURNACE ROOMS 1ST, 2ND, AND BASEMENT OPENINGS AROUND PIPES AND DUCK WORK , IN WALLS, FLOORS, AND CEILING. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | INTERIOR ALL FLOORS EVIEDENCE OF MICE, WITH DROPPINGS AND CAPTURED MICE. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
REMOVE STAGNANT WATER BSMT | BASEMENT STANGNANT WATER IN DWELLING UNIT AND AND REAR UTILITY AREA. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | INTERIOR 1ST FLOOR BATHROOM NEAR SHOWER AREA FLOOR DEFLECTS UNDER LOAD, AND 2ND FLOOR UNDER BATH TUB ROTTED FLOORS. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | INTERIOR 1ST FLOOR APARTMENT DININGROOM AND KITCHEN WALLS AND CEILING EVIDENCE. BASEMENT KITCHEN CEILING SEVERE WATER PENETRATION, WALLS THOUGH-OUT UNIT, LIVING , KITCHEN, BATHROOM, AND BEDROOM. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EXTERIOR NORTH AND SOUTH ELEVATIONS SECTIONS OF WALLS PLYWOOD AND ROOFING PATCH WORK REPAIRS, IMPROPER MATERIALS. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOWS BASEMENT AND 1ST FLOOR, PLYWOOD, AND FOAM BOARD UPS TO WINDOWS, NORTH AND SOUTH ELEVATIONS. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR ENCLOSED 2 STORY PORCH. WALLS PLYWOOD SECTIONS, AND ROTTED STUDS AND PLYWOOD; FOUNDATION NOT VERIFIED; COLUMNS 4X6, UNDER SIZED AND TOENAILED CONNECTIONS; BEAMS 4X6 UNDER SIZED AND TOE NAILED CONNECTIONS; JOIST 2X6 NAILED CONNECTIONS, SPANNED 9'-10' AND SPACED 20" APART; DECKING ROTTED, AND EXCESSIVE PITCH, EXCESSIVE STORAGE; RAILINGS HORIAZONTAL 31" HIGH , WITH SPACING UP TO 10 1/2"; ROOF ROTTED ROOF JOIST; PROVIDE PLANS AND PERMIT. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQUIRED | BASEMENT REMOVE ALL WALLS AND FIXTURES INSTALLED IN BASEMENT WITH OUT PERMIT. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
SEPARATION OF DWELLING ADEQUAT | INTERIOR BASEMENT SEPERATION SINGLE LAYER OF 1/2" DRYWALL WITH OPEN STUDS IN UTILITY AREA HOT WATER TANK, STORAGE, AND FURNACE. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
LIGHT AND VENT | INTERIOR BASEMENT WINDOWS TOO SMALL TO MEET LIGHT/ AND VENT REQUIREMENTS. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR BASEMENT INTERIOR BASEMENT SUBMIT PLANS AND PERMIT TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE TO ORIGINAL STATE. (SOME ROOMS CEILING HEIGHT 6'3". | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
SECURE RACEWAY | SERVICE SUPPORT REAR | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
OUTDOOR ARMORED CABLE | EXTERIOR SOUTH REAR | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | BASEMENT WATER DAMAGE, ELECTRICAL PERMIT IS REQUIRED | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
WORKING SPACE | REMOVE DEBRIS | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 1438 N NORTH PARK AVE | PERMIT | PASSED | View | |
OPEN | 1438 N NORTH PARK AVE | PERMIT | FAILED | View | |
EGRESS -BASEMENT | INTERIOR BASEMENT UNIT 1 EXIT TO GRADE. | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |
CIRCUIT ONE UNIT ONLY | PUBLIC METER | 1438 N NORTH PARK AVE | COMPLAINT | PASSED | View |