Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SEND EX. METAL LETTER | EXPOSED METAL LETTER | 2146 N HALSTED ST | COMPLAINT | PASSED | View |
PROTECT METAL MEMBERS | PROTECT METAL MEMBERS | 2146 N HALSTED ST | COMPLAINT | PASSED | View |
REPAIR EX. MET. | ENGINEER REPORT | 2146 N HALSTED ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | PLEASE NOTE THAT ALL THREE BUILDINGS HAVE DIFFERENT OWNERS, - 2150, -2148, -2146 ALL THREE (3) REAR PORCH'S ARE CONNECTED, PORCH VIOLATION APPLY FOR ALL THREE (3) BUILDINGS, - COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES: FOUNDATION STATUS UNKNOWN, SOME FOUNDATION BASES FORM BY POURING CONCRETE IN AROUND COLUMNS, - BALUSTERS ARE ON THE EXTERIOR OF GUARDRAIL,- 2X6 FLOOR JOIST ARE UNDERSIZE THROUGHOUT ENTIRE PORCH, - 6X6 AND 4X4 COLUMNS ARE OUT OF PLUMB, BOWING AND TWISTING, COLUMNS HAVE INADEQUATE HALF - LAP JOINTS FASTENED WITH ( 2 ) ½¿ BOLTS ONLY SPLICE IS LESS THE 18¿, - LEDGER BOARDS NOT FASTENED TO MASONRY, - 6X6 COLUMNS HAVE A BUTT JOINT AND TOE NAIL FASTENED, - UPPER AND LOWER STAIR STRINGERS INADEQUATELY SUPPORTED AT HEADER AND BOTTOM JOIST, - AT SECOND FLOOR, STAIRWELL IS LEANNING DANGEROUSLY, - SOME 6X6 AND 4X4 COLUMNS ARE BUTT JOINT AND POORLY NAIL, - SOME 6X6 COLUMNS ARE DRY ROT SPLITTING AND TWISTING, - PLANS AND PERMIT ARE REQUIRED. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | 1ST FLOOR SPEX FRONT AND REAR MISSING EMERGENCY EXIT SIGNS | 2146 N HALSTED ST | PERIODIC | FAILED | View |
ILLUMINATE EXIT AREAS | 1ST FLOOR SPEX MISSING EMERGENCY LIGHTS. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR SPEX MISSING CARBON MONOXIDE DETECTOR AT SALES AREA AND MECHANICAL ROOM. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR SPEX MISSING SMOKE DETECTOR AT SALES AREA AND MECHANICAL ROOM. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | MISSING OR EXPIRED FIRE EXTINGUISHER | 2146 N HALSTED ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. UNABLE TO CONFIRM INTERIOR COMPLAINT OF POTENTIAL SAFETY HAZARDS. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
PROVIDE | PROVIDE PER CODE SECTION 14A-6-603.3 THROUGH 14A-6-603.3.4. WEST ELEVATION METAL DUCTWORK STRUCTURE PERMANENTLY INSTALLED ON THE EXTERIOR OF A BUILDING. PROVIDE CRITICAL EXAMINATION REPORT ON EXPOSED METAL STRUCTURES BY A REGISTERED DESIGN PROFESSIONAL WITHIN 2 YEARS AFTER ITS INSTALLATION AND AT LEAST ONCE EVERY 5 YEARS AFTER THE INITIAL INSPECTION. THE REGISTERED DESIGN PROFESSIONAL MUST PREPARE THE SIGNED AND SEALED WRITTEN REPORT ON THE EXTERNAL STRUCTURAL CONDITION AND INTEGRITY OF THE EXPOSED METAL STRUCTURE AND PROVIDE TO OWNER. PROJECTIONS SUCH AS CANOPIES, MARQUEES, AWNINGS, MUST BE MAINTAINED IN GOOD REPAIR AND BE PROPERLY ANCHORED. METAL SURFACES SUBJECT TO RUST OR CORROSION MUST BE COATED TO INHIBIT SUCH RUST AND CORROSION, AND SURFACES WITH RUST OR CORROSION MUST BE STABILIZED AND COATED TO INHIBIT FUTURE RUST AND CORROSION. SEND REPORTS TO: DEPARTMENT OF BUILDINGS CODE COMPLIANCE GROUP, 2045 W. WASHINGTON BLVD. CHICAGO, IL 60612. (14A-6-603.3 THROUGH 14A-6-603.3.4, 14X-3-303.2, 14X-3-303.9, 14X-5-505.12, 14R-3-307, 14R-3-307.6 AND 14A-4-404.8) | 2146 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /EXTERIOR WALL - SPALLED BRICK SECTIONS WITH WASHED OUT MORTAR [MULTIPLE LOCATIONS]; LARGE VERTICAL FRACTURES AT WEST ELEVATION; WEST WALL PULLING AWAY; CRACKED, CRUMBLING PARGE COAT EXPOSING SPALLED BRICK SECTIONS WITH WASHED OUT MORTAR UNDERNEATH. PERMIT REQUIRED FOR MASONRY REPAIRS. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR ELEVATION - TOILET, COUCH, HOUSEHOLD ITEMS AND DEBRIS NEAR GARBAGE AREA. REAR ELEVATION - MAN HOLE COVER MISSING [COVERED WITH (2) 2X6S AT TIME OF INSPECTION]. | 2146 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR ELEVATION /EXTERIOR 3-STORY WOOD PORCH SYSTEM - 6X6 COLUMNS ROTTED WITH FLAKY, PEELING PAINT NEAR CENTER; 6X6 COLUMN 1/2 LAP JOINT UNDERSIZED AND FASTENED WITH ONLY (3) BOLTS; GUARD RAILS FASTENED TO COLUMNS WITH NAILS ONLY. PERMIT REQUIRED FOR PORCH REPAIRS. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2146 N HALSTED ST | PERIODIC | FAILED | View |