Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING WINDOW SCREENS. | 5319 S INDIANA AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | CB132046.- 2ND FLOOR - FURNACE OUT OF SERVICE. THERMOSTAT SET AT 90F FURNACE. FURNACE DID NOT START.(14X-3-305.1, 14X-8-804.1 THRU 14X-8-804.4 AND 14X-8-804.5). | 5319 S INDIANA AVE | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY - SPALLING BRICKS. | 5319 S INDIANA AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | SOUTH PASSAGEWAY, STONE FOUNDATION WALL - WASHED OUT MORTAR. | 5319 S INDIANA AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3 STORY PORCH: UNDERSIZED 6"X6" BEAMS SPAN 11'-5" AND ARE BENT.; UNDERSIZED 2"X6" DECK JOISTS SPAN 11'-5".; TREADS ARE ONLY 9" AND ARE SPLIT.; COLUMN ARE SET ON ON TOP OF OTHER AND FASTENED WITH LIGHT GAGE TIE STRAPS.; NORTH 2ND FLOOR BEAM IS SEPARATING SIDEWAY FROM COLUMN.; COLUMN RIM JOIST AND BEAM NOTCH HAPPANING ON THE SAME PLACE.; STRINGERS FASTENED WITH NAILS ONLY.; COLUMNS ERECTED ON TOP OF CONCRETE, FOOTING STATUS UNKNOWN. PORCH IS IN D&H CONDITION. PLANS AND PERMIT ARE REQUIRED TO REPLACE PORCH. | 5319 S INDIANA AVE | COMPLAINT | FAILED | View |