| INSTALL GFCI PROTECTION ON KITCHEN ISLAND. 18-27-210.8 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| BLUE WIRE IN PANEL USED AS NEUTRAL AND/OR GROUND. 18-27-200.5 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| PROVIDE PROPER OVERCURRENT PROTECTION. 18-27-240.2 AND 18-27-240.4 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| ALL ELECTRICAL EQUIPMENT MUST BE INSTALLED IN A WORKMANLIKE MANNER. SWITCH INSTALLED UPSIDE DOWN AT 1ST FLOOR CLOSET. 18-27-110.12 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| INSTALL DETAILED AND LEGIBLE PANELS SCHEDULES. 18-27-110.22 AND 18-27-384.13 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| INSTALL COLD WATER GROUND CONTINUOS FROM SERVICE PANEL TO WATER METER. CONTRACTOR DELIBERATELY INSTALLED ONLY 5' OF #4 AWG ON BOTH ENDS OF CONDUIT. 18-27-250.50 AND 18-27-250.30 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| NO GROUND AT RECEPTACLES IN 2 OUT OF 3 BEDROOMS ON 2ND FLOOR. 18-27-300.12 | 6412 S AUSTIN AVE | PERMIT | PASSED | View | |
| OPEN | 6412 S AUSTIN AVE | PERMIT | FAILED | View |