Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REBUILD GARAGE OR SHED | GARAGE WITH SEVERE MORTAR JOINT & SPALLED BRICK SECTIONS, ROTTING & PEELING PAINT ON DOORS | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | PROVIDE FULL ACCESS TO INTERIOR, PORCH SYSTEM, UNDER PERMIT #100149381 | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
REPAIR DOWNSPOUT | DOWNSPOUTS MISSING NORTH AND SOUTH ELEVATION | 4911 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | BOLT STRINGERS TO MASONRY WALL INDAEQUATE HEADROOM SIX 6 FEET FOR EGRESS GRADE TO FIST EAST ELEVATION REPAIR EGRESS GRADE TO FIRST EAST ELEVATION REPAIR | 4911 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH MASONRY WALL OF SEMI-ENCLOSED PORCH WHERE GROUT IS ERODING AND REVEALS SEPARATION BETWEEN MASONRY WALLS BUILDING AND PORCH | 4911 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH LINTEL SHOWS DEFLECTION RETAINING WALL AT PRIMARY STAIRWAY FRONT OF BUILDING IS CRUMBLING OBTAIN REPAIR PERMIT | 4911 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | AT WEST ELEVATION BROEKN CONCRETE SERVICE WALK | 4911 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH-3 LEVELS-1ST STAIR LANDING HAS NO JOIST HANGERS.NO BOLTS AT UPPER STAIR CONECTIONS.GRADE TO 1ST-MISSING SECTION OF STAIR BANISTER. | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | NO PERMIT ON FILE FOR RECENT PORCH REPAIRS.PERMIT AND PLANS REQUIRED. | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
ARRANGE FOR REINSPECTION REGAR | SINGLE FAMILY HOME(BUNGALOW)-DOB DATA BASE SHOWS 9 DU'S.NEED ENTRY TO VERIFY OCCUPANCY. | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | EAST: BRICK FENCE OVER 6 FEET WITH A LARGE SECTION SEVERELY OUT OF PLUMB (COLLAPSE HAZARD), SEVERELY ERODED MORTAR JOINTS & SPALLED BRICK SECTIONS | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST: SEVERELY BROKEN/UNEVEN SECTION OF SERVICE WALK & DRIVEWAY | 4911 N CENTRAL PARK AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INTERIOR INSPECTION TO VERIFY OCCUPANCY | 4911 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |