The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
APPROVE PLANS ON SITE | 538 W 119TH ST | PERMIT | FAILED | View | |
ARRANGE COMPLETED PERMIT INSP. | 538 W 119TH ST | PERMIT | FAILED | View | |
FOLLOW PLANS/RESUBMIT REVISED | 538 W 119TH ST | PERMIT | FAILED | View | |
FOLLOW PLANS/RESUBMIT REVISED | 538 W 119TH ST | COMPLAINT | FAILED | View | |
SUBMIT REVISED PLANS | 538 W 119TH ST | COMPLAINT | FAILED | View | |
ARRANGE FOR RE-INSPECTION | NO PRV`S | 538 W 119TH ST | PERMIT | PASSED | View |
PRV HIGH SIDE | FOR ONE TECUMSEH 3 HP. COMPRESSOR WITH DUAL 6" X 28" RECEIVER ,SERVING W-IN FREEZER. LOCATED ON LOW REAR ROOF. | 538 W 119TH ST | PERIODIC | FAILED | View |
PRV HIGH SIDE | FOR ONE TECUMSEH 3 HP. COMPRESSOR WITH DUAL 6" X 28" RECEIVER ,SERVING W-IN FREEZER. LOCATED ON LOW REAR ROOF. | 538 W 119TH ST | PERIODIC | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE | REDUCED AISLES THROUGHOUT BUILDING 24", 29", 32", 30", 28", 35", 31", 25", CAUSE IS OVERSTOCK ON FLOORS, SHELVING UNITS, COOLERS. THIS CAUSES A DANGEROUS AND HAZARDOUS CONDITION FOR ALL OCCUPANTS OF THE BUILDING. (15-4-880, 15-4-900) | 538 W 119TH ST | COMPLAINT | PASSED | View |
NO BARBED WIRE ON FENCE < 8FT | NORTH ELEVATION HAS STEEL RAZOR WIRE CAUSING A DANGEROUS AND HAZARDOUS CONDITION. | 538 W 119TH ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | WOOD PICKET FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. | 538 W 119TH ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | MERCHANDISE OVERSTACKED ON SHELVING UNITS CAUSING A DANGEROUS AND HAZARDOUS CONDITION TO OCCUPANTS, COLLAPSING HAZARD. | 538 W 119TH ST | COMPLAINT | PASSED | View |
REMOVE | 5 GALLON BUCKET ACTING AS SANITARY PITT IN MEAT CUTTING ROOM FOR CONDENSATE WATER AND PROVIDE PROPER SANITARY PITT, LID AND VENT. (18-29-802.1) CREATING A DANGEROUS AND HAZARDOUS CONDITION. | 538 W 119TH ST | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | HAND SINK NOT TRAPPED IN MEAT CUTTING ROOM, DANGEROUS AND HAZARDOUS. | 538 W 119TH ST | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMIT FOR 3 COMPARTMENT SINK AND HAND SINK NORTHWEST ELEVATION. | 538 W 119TH ST | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | NO PERMIT FOR HAND SINK AND SANITARY PITT IN MEAT CUTTING ROOM. | 538 W 119TH ST | COMPLAINT | PASSED | View |
VENT 5' WITHIN TRAP | REMOVE PVC WASTE PIPE FOR HAND SINK AND THREE COMPARTMENT SINK NORTHWEST ELEVATION. | 538 W 119TH ST | COMPLAINT | PASSED | View |
VENT 5' WITHIN TRAP | REMOVE PVC WASTE PIPE FOR HAND SINK AND DISCHARGE PIPE FOR SANITARY PITT IN MEAT CUTTING ROOM. | 538 W 119TH ST | COMPLAINT | PASSED | View |
PRV BALLCOCK,VB,OR AIR GAP | HAND HELD SPRAY FOR HAND SINK IN MEAT CUTTING ROOM. | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO HAND SINK NORTHWEST ELEVATION, HAND SINK IN MEAT CUTTING ROOM, LAVATORY AND TOILETS MEN'S AND WOMEN'S RESTROOM EAST ELEVATION. | 538 W 119TH ST | COMPLAINT | PASSED | View |
SEAL DRAIN OPENING UNUSD FIXTR | CREATING SEWER GAS SOUTHEAST ELEVATION RESTROOM. | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE | RPZ ON HAND HELD SPRAY AT TOILET RESTROOM SOUTHEAST ELEVATION. (18-29-608.13.2) | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE OPEN FRONT TOILET SEAT | TOILET RESTROOM NORTHEAST ELEVATION. | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE | TEMPERING VALVES LAVATORIES NORTHEAST AND SOUTHEAST ELEVATION. (18-29-607.1.1) | 538 W 119TH ST | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL 4" PVC FOR STORM DRAINS ENTIRE BUILDING. | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE PROPER CLEARANCE FOR HAND SINK INSTALLED OVER MOP SINK NORTHWEST ELEVATION. (18-29-405.3.1) | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE DRINKING FOUNTAIN FOR RESTROOMS EAST ELEVATION. (18-29-403.7) | 538 W 119TH ST | COMPLAINT | PASSED | View |
PROVIDE | LABLE RESTROOMS MEN AND WOMEN'S EAST ELEVATION. (18-29-403.1) | 538 W 119TH ST | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 538 W 119TH ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE UNAPPROVED CORD CONNECTIONS TO LIGHT FIXTURES ON EXTERIOR AND INTERIOR OF STORE - DANGEROUS. | 538 W 119TH ST | COMPLAINT | PASSED | View |
INSTALL COVERS | INSTALL FILLERS TO OPEN BOXES IN CEILING AND AT BOXES BY ELECTRICAL PANELS - DANGEROUS. | 538 W 119TH ST | COMPLAINT | PASSED | View |
(18-27-110.26) REMOVE ALL CLUTTER FROM IN FRONT OF ELECTRICAL PANELS. NEED MINIMUM WORKING SPACE IN FRONT OF ALL ELECTRICAL EQUIPMENT. | 538 W 119TH ST | COMPLAINT | PASSED | View | |
SEE INSPECTOR COMMENTS | (18-27-110.5) REDO ELECTRICAL SYSTEM BEHIND MEAT CASE IMPROPERLY INSTALLED. | 538 W 119TH ST | COMPLAINT | PASSED | View |
INSTALL COVERS | INSTALL COVERS TO ALL OPEN EQUIPMENT AT COMPRESSORS - DANGEROUS. | 538 W 119TH ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE ALL UNAPPROVED EXTENSION CORDS AND POWER STRIPS AND INSTALL ADDITIONAL OUTLETS TO AVOID USE OF CORDS - DANGEROUS. | 538 W 119TH ST | COMPLAINT | PASSED | View |
(18-27-110.11) ALL ELECTRICAL BOXES AND CONNECTIONS ON EXTERIOR AND IN WALK-IN COOLER MUST BE WEATHERPROOF - DANGEROUS. | 538 W 119TH ST | COMPLAINT | PASSED | View | |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES IN WALK-IN COOLER. BOXES, FITTINGS AND FIXTURES MUST BE WEATHERPROOF. | 538 W 119TH ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE CORD CONNECTION TO DISCONNECTS IN WALK-IN COOLER. | 538 W 119TH ST | COMPLAINT | PASSED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 538 W 119TH ST | COMPLAINT | PASSED | View | |
ARRANGE COMPLETED PERMIT INSP. | 538 W 119TH ST | COMPLAINT | FAILED | View | |
OPEN | 538 W 119TH ST | PERMIT | PASSED | View |