The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE SERVICE TO FRONT AND REAR BUILDINGS | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | INSTALL PUBLIC METER | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | UNIT 2R - ROOM TEMPERAT - 57F AT 2:00PM. HEAT SYSTEM IS OFF AT TIME OF INSPECTION. GAS SERVICE SHUT OFF TO UNIT, NO HEAT PROVIDED. | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | UNIT 2R - MISSING SMOKE DETECTORS. | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | UNIT 2R - MISSING CARBON MONOXIDE DETECTORS. | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | UNIT 2R - HOT WATER SUPPLIED AT ONLY 57F. GAS SERVICE SHUT OFF TO UNIT, NO HOT WATER FURNISHED. | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | WEST EXTERIOR 2 STORY PARTIALLY ENCLOSED WOOD PORCH SYSTEM BETWEEN MAIN BUILDING AND COACH HOUSE - FOUNDATIONS UNKNOWN, COLUMNS COMPLETLY ROTTED THROUGH SECTION OF ENCLOSE PORCH NOT SUPPORTED. STAIR 4X4 COLUMNS SCABBED. STAIR RISE GREATER THAN 12 FOOT WITHOUT A LANDING. BEAM TO COLUMN CONNECTIONS MISSING BOLTS. STRINGERS MISSING BOLTED CONNECTIONS. DANGEROUS AND HAZARDOUS. | 2008 S ALLPORT ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR PORCH WITH CATWALK (1 STORY)-COLUMNS ARE SET ON TOP OF CONCRETE BASES, ARE OVERCUT AND OUT OF PLUMB AT THE EDGE BEAM CONNECTIONS. ROTTED BEAMS. FRACTURED RIM JOIST. FLIGHT OF STAIRS SHIFT LATERALLY UPON LOAD. SAGGING CATWALK. MOST COMPONENTS ARE WORN. MOST COMPONENTS ARE ONLY NAILED TOGETHER AT THE CONNECTIONS. SUBMIT PLANS AND OBTAIN PERMIT FOR PORCH AND CATWALK REPLACEMENT. | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE TO 1F, 2F AND 1R UNITS - UNVERIFIED DETECTORS, EGRESS AND CONDITIONS. | 2008 S ALLPORT ST | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | UNIT 2R - FURNACE AND HOT WATER HEATER - OUT OF SERVICE AT TIME OF INSPECTION. | 2008 S ALLPORT ST | COMPLAINT | FAILED | View |