The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | REAR PORCH DANGEROUS AND HAZARDOUS WITH SEVERE ROTT IN STRUCTURAL MEMBERS. REAR PORCH ROTTING COLUMNS AND BEAMS. ROTTING TREADS, DECKING, RAILS, STRINGERS, JOISTS. ROTTING PORCH ROOF DECKING. FOUNDATION RETAINING WALL WITH FRACTURES AND BOWING BRICK. 2X8 JOISTS SPAN 12'. STACKED BEAMS AND COLUMNS, STACKED COLUMNS, INSUFFICIENT CONNECTIONS. PORCH WITH SIGNIFICANT PITCH. INSUFFICIENT PORCH ROOF BEAM AND COLUMN CONNECTIONS. NO BASEMENT STAIRS HAND OR GUARDRAIL. PORCH PARTIAL ENCLOSURE SEPERATING SHEETING FROM STRUCTURE. OBTAIN COMPLETE PLANS AND PERMIT FOR REPLACEMENT OF PORCH. | 3515 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | REAR PORCH PARTIAL ENCLOSURE WITH TORN AND MISSING SIDING. | 3515 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | FRONT WINDOW FRAMES WITH FLAKING PAINT AND ROTTING WOOD. | 3515 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | FRONT DOOR AND SIDE LIGHT PANELS WITH ROTTING WOOD. | 3515 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS WITH LOOSE AND UNSECURED HAND AND GUARD RAILS. ROTTING AND FRACTURED TREADS. ROTTING AND BUCKLING DECKING. ROTTING COLUMNS. INSUFFICIENT BEAM, COLUMN, JOIST, AND STRINGER CONNECTIONS. OBTAIN PERMIT. | 3515 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | POST I.D. | 3515 N SHEFFIELD AVE | COMPLAINT | PASSED | View |
REPAIR CORNICE | FRONT ELEVATION /CORNICE - OPEN MORTAR JOINTS. | 3515 N SHEFFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTHWEST ELEVATION /EXTERIOR WALL @2ND, 3RD FLOORS - SPALLED BRICKS, WITH WASHED OUT MORTAR. | 3515 N SHEFFIELD AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT ELEVATION /SERVICE WALK - CRACKED, BROKEN, WITH SECTIONS MISSING. | 3515 N SHEFFIELD AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE /EXTERIOR WALLS - FLAKY, PEELING PAINT. | 3515 N SHEFFIELD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /NO RESPONSE. UNABLE TO VERIFY DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAY SYSTEMS. | 3515 N SHEFFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION [GRADE TO BASEMENT] /EXTERIOR STAIRS - HANDRAIL MISSING. | 3515 N SHEFFIELD AVE | COMPLAINT | FAILED | View |