Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSUFFICIENT MEANS OF EGRESS | SOUTH EXTERIOR STAIRS MISSING, REDUCING THE NUMBER OF EGRESS EXITS TO ONE CAUSING A DANGEROUS AND HAZARDOUS CONDITION. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ALL LEVELS MISSING SMOKE DETECTORS. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ALL LEVELS MISSING CARBON MONOXIDE DETECTORS. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | UNSANITARY LIVING CONDITIONS BASEMENT/ATTIC HAS LARGE AMOUNTS OF FECES, GARBAGE AND DEBRIS THROUGHOUT ALL LEVELS. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST/SOUTH 1ST FLOOR WINDOW PANES BROKEN. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | BROKEN BOTTOM RAIL OF TOP SASH AT 1ST FLOOR. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | 1ST FLOOR FRONT PORCH ONE STORY: MASONRY PILASTERS ARE CRACKED WITH LOOSE STONES, MISSING MORTAR THROUGHOUT ALL THREE PILASTERS - 6X6 COLUMNS ARE OUT OF PLUMB, NOT ATTACHED TO BASE FOUNDATION OR ROOF BEAM - CENTER COLUMN WAS CUT AND NEVER REPLACED, BEAM ABOVE IS DEFLECTING DUE TO COLUMN REMOVAL - GUARDRAILS ARE LESS THAN 42" IN HEIGHT, GUARDRAIL PICKETS MISSING ON SEVERAL SPOTS - PICKETS ARE NAILED ON EXTERIOR - TREAD AND RISERS ARE UNEVEN AND LOOSE. 2X8'S SUPPORTING THE PORCH FLOOR ARE ROTTEN - MISSING MID SPAN BRIDGING WITH RUSTED NAILS. PORCH ROOF IS SEVERELY DAMAGED, POORLY CONSTRUCTED, ROOF CEILING IS DEFLECTING AT SEVERAL SPOTS. PORCH MIGHT COLLAPSE AT ANY TIME WITHOUT WARNING. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICE WITH MISSING METER - TENANT STEALING POWER. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS. ALL FIXTURES AND SUPPORT BOXES MUST BE WEATHERPROOF. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS. (13-12-360) | 1479 W 72ND PL | COMPLAINT | FAILED | View | |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES THROUGHOUT 1ST FLOOR, ATTIC AND BASEMENT. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | REMOVE ALL UNAPPROVED EXTENSION CORDS THROUGHOUT 1ST FLOOR. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVERS TO ALL OPEN JUNCTION BOXES. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
(18-27-210.8) INSTALL GFCI'S TO WET LOCATIONS. | 1479 W 72ND PL | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR STAIR | SOUTH EXTERIOR STAIRS MISSING. | 1479 W 72ND PL | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | LOOSE AND MISSING WINDOW PUTTY, 1ST AND 2ND FLOORS. | 1479 W 72ND PL | COMPLAINT | FAILED | View |