Chicago Building Violations Data: 30 Violations
Violation Inspector Comments Address Category Status View
TEST G & S FRT ELE FULL LOAD ONLY. (WOODEN RAILS). EV004835. 5643 W NORTH AVE PERIODIC FAILED View
ARRANGE FOR INSPECTION CONTACT INSPECTOR STEPHEN MCGANN #971 @ (312)743-3562 ON TUESDAYS BETWEEN 8-9AM. 5643 W NORTH AVE PERIODIC FAILED View
REPAIR LINTELS SR#06-00607789 2ND FLOOR LINTELS ROTTED, SAGGING 5643 W NORTH AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL BRICKS BULGING FRONT 2ND FLOOR OVER LINTELS, FRACTURES IN BRICKS, CRACK AND OPEN MORTAR JOINTS 5643 W NORTH AVE COMPLAINT FAILED View
CHIMNEY CAPPING REAR-NO CHIMNEY CAP 5643 W NORTH AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNERSHIP I.D. POSTED 5643 W NORTH AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT INTERIOR STAIRS TO BASEMENT- NO HANDRAILS 5643 W NORTH AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR OBTAIN PERMIT TO REPLACE LINTELS AND FOR MASONARY REPAIRS 5643 W NORTH AVE COMPLAINT FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY MAINTAIN FREIGHT IN SAFE WORKING OPERATION FREIGHT IS CURRENTLY OUT OF SERVICE 5643 W NORTH AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PERFORM CAT5 SAFTY TEST. PREVIOUSLY WRITTEN IN 2009. 5643 W NORTH AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA PROPERLY MAINTAIN FRIEGHT ELEVATOR TO SAFE WORKING ORDER. PREVIOUSLY WRITTEN IN2015. 5643 W NORTH AVE PERIODIC FAILED View
MAINTAIN OR REPAIR ELECT ELEVA IF FRIEGHT ELEVATOR IS NOT GOING TO BE REPAIRED DECOMMISION PERMIT MUST BE OBTAINED AND ELEVATOR TAKRN OUT OF SERVICE BY LICENCED ELEVATOR CONTRACTOR WITH CITY OF CHICAGO. 5643 W NORTH AVE PERIODIC FAILED View
ILLUMINATE EXIT AREAS THERE IS NO EXIT ILLUMINATION AT THE ROOF TOP EXIT PATH TO THE REAR PORCH IT IS EXTREMELY DARK IN THIS EGRESS AREA DANGEROUS AND HAZARDOUS 5643 W NORTH AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS THE 2 REAR APARTMENTS HAVE NO SMOKE DETECTORS THE REAR (ENCLOSED) STAIRWELL HAS NO SMOKE DETECTORS 5643 W NORTH AVE COMPLAINT FAILED View
PLANS & PERMITS REQUIRED AT THE REAR HALF OF THE BASEMENT AND THE REAR 2ND FLOOR APARTMENT THERE IS ONGOING WORK THAT REQUIRES PLANS AND PERMITS (BATHROOM AND HOT TUB INSTALLATION/WALL FRAMING WORK IN PROGRESS) 5643 W NORTH AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID THE 2 REAR APARTMENTS HAVE NO CARBON MONOXIDE DETECTORS 5643 W NORTH AVE COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL THE 1ST FLOOR PARTY SPACE HAS NO FIRE EXTINGUISHES 5643 W NORTH AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS THE 1ST FLOOR PARTY SPACE HAS NO WORKING SMOKE DETECTORS 5643 W NORTH AVE COMPLAINT FAILED View
CHIMNEY THERE IS A STEEL LINTEL SUPPORTING A 8" WIDE OPENING FROM 1 ROOM TO ANOTHER IN THE BASEMENT THIS LINTEL IS SEVERELY RUSTED/WARPED PLANS AND PERMIT ARE REQUIRED TO REPLACE THIS STRUCTURAL LINTEL 5643 W NORTH AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR THE FIRST FLOOR STORE FRONT COMMERCIAL SPACE HAS BEEN ALTERED INTO A DEDICATED PARTY VENUE THAT IS COMPLETELY DEVOID OF ANY LICENSES LIQUOR AND FOOD ARE BEING SOLD,LARGE GATHERINGS ARE PAYING THE LANDLORD TO HOST THESE PARTIES CASH COVER CHARGES AT THE DOOR AND ON LINE TICKET SALES ARE THE MEANS TO ACCESS THESE PARTIES THE SPACE (1ST FLOOR AND BASEMENT) HAS BEEN COMPLETELY REHABBED WITHOUT ANY PLANS OR PERMITS ALSO THE 1ST FLOOR AND BASEMENT SPACES HAVE BEEN COMPLETELY REHABBED WITHOUT PLANS OR PERMITS ALSO A 2 STORY REAR PORCH HAS BEEN BUILT WITHOUT PLANS OR PERMIT ALSO IN ADDITION TO A 2ND FLOOR FRONT APARTMENT (NO ENTRY) 2 OTHER APARTMENTS HAVE BEEN INSTALLED ON THE 2ND FLOOR REAR AREA WITHOUT PLANS OR PERMITS A DEPARTMENT OF BUILDINGS AND A BUSINESS AFFAIRS/CONSUMER PROTECTION CLOSURE HAS BEEN ISSUED/POSTED 5643 W NORTH AVE COMPLAINT FAILED View
POST APPROVED OCCUPANCY CARD THE 1ST FLOOR PARTY SPACE HAS NO OCCUPANCY PLACARD 5643 W NORTH AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU THE REAR HALF OF THE BASEMENT IN THIS MIXED USE BUILDING HAS OPEN WOOD FLOOR JOISTS AT THE CEILING AT LEAST 1 HOUR FIRE SEPARATION IS REQUIRED PLANS AND PERMIT ARE REQUIRED 5643 W NORTH AVE COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE THE 2ND FLOOR REAR APARTMENTS HAVE AN EGRESS PATHWAY ACROSS AN OPEN SNOW COVERED ROOF TO A REAR PORCH THAT IS UTTERLY UN-PASSABLE DUE TO EXCESSIVE SNOW COVER THE ROOF EGRESS HAS NO GUARDRAILS OR RAISED EXIT PLATFORM ABOVE THE (SLIPPERY) ROOF MEMBRANE DANGEROUS AND HAZARDOUS 5643 W NORTH AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID THE 1ST FLOOR PARTY SPACE HAS AN INOPERABLE CARBON MONOXIDE DETECTOR 5643 W NORTH AVE COMPLAINT FAILED View
LOAD BEARING ARCH. REPORT THE 1ST FLOOR PARTY SPACE IS BEING OPERATED AS A SMALL ASSEMBLY PPA PARTY VENUE A FLOOR LOAD ANALYSIS IS REQUIRED 5643 W NORTH AVE COMPLAINT FAILED View
INSUFFICIENT MEANS OF EGRESS THE 2ND FLOOR FRONT AND THE 2 REAR,2ND FLOOR APARTMENTS ALL HAVE ONLY 1 MEANS OF EGRESS 5643 W NORTH AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM THE REAR INTERIOR STAIR FROM THE BASEMENT TO THE 2ND FLOOR ARE IN DISREPAIR THE FLOOR JOISTS SUPPORTING THE 1ST FLOOR LANDING ARE SEVERELY ROTTED AND AS WELL AS BEING DETACHED FROM THEIR RESPECTIVE RIM JOISTS DANGEROUS AND HAZARDOUS PLANS AND PERMIT REQUIRED FOR REPAIRS 5643 W NORTH AVE COMPLAINT FAILED View
INSTALL EXIT SIGN THERE IS NO EXIT SIGNAGE FOR THE 2 REAR APARTMENT EGRESS AREAS 5643 W NORTH AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY THE 1ST FLOOR PARTY VENUE HAS 2 (EAST ELEVATION) EXIT DOORS THAT CANNOT BE OPENED DUE TO HEAVY SNOW COVER DANGEROUS AND HAZARDOUS 5643 W NORTH AVE COMPLAINT FAILED View
FLOOR LOAD CARDS THE 1ST FLOOR PARTY SPACE IS BEING OPERATED AS A SMALL ASSEMBLY PPA PARTY VENUE A FLOOR LOAD CARD IS REQUIRED 5643 W NORTH AVE COMPLAINT FAILED View