Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REBUILD GARAGE OR SHED | 6649 S STEWART AVE | COMPLAINT | FAILED | View | |
NO POSTED ADDRESS | PROPERTY HAS NO ADDRESS POSTED. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EXTERIOR FRONT STONE 1 STORY PORCH- GUARDRAILS METEL POLE MISSING PICKETS, AND GUARDRAIL BELOW 42" WITH OUT PICKETS, BOTH HAND AND GUARDRAILS SPACING IN EXCESS OF 2-3'. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT EXTERIOR WALL STONES WASHED OUT MORTAR JOINTS. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EXTERIOR FRONT WINDOW SILLS WASHED OUT MORTAR JOINTS. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | MISSING SCREENS THROUGHOUT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
RAT PROOF EXTERIOR DOOR | REAR EXTERIOR DOOR GAPS BETWEEN DOOR AND JAMB. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | BUILDING DROPPINGS THROUGHOUT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | PROPERTY EVIDENCE OF RODENTS, DROPPINGS 1ST AND BASEMENT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
1/2HR FLR OVER BSMT,3+DU,PRE57 | BASEMENT CEILING OPEN AND EXSPOSED JOIST. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT SEPARATION | BASEMENT FURNACES NOT ENCLOSED. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | BASEMENT CEILING EXSPOSED WIRES. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
BASEMENT, DISCONTINUE | BASEMENT REMOVE ALL WALLS AND FIXTURES INSTALLED IN BASEMENT WITHOUT PERMIT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT SEPERATION OF 1/2" DRYWALL BETWEEN UNITS AND FURNACE ROOM. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
LIGHT AND VENT | BASEMENT WINDOWS DONT MEET LIGHT AND VENTALATION REQUIREMENTS. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | BASEMENT SUBMIT PLANS AND PERMIT TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE TO ORIGINAL STATE. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | BASEMENT NO HEAT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | BASEMENT NO HOT WATER. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER'S INFORMATION SIGN. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO APARTMENTS 2 & 3, UNABLE TO VERIFY DETECTORS. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1ST FLOOR, EAST WINDOW PANE BROKEN. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICEWALK UNEVEN SURFACE. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | EVIDENCE OF MICE- DROPPINGS THROUGHOUT BASEMENT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | REAR EXTERIOR DOOR TO BUILDING DOES NOT CLOSE SECURELY. 1ST FLOOR REAR DOOR TO APARTMENT DOES NOT CLOSE EITHER. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | BATHROOM FLOOR UNEVEN AND CAVING INWARD AROUND TOILET, TILES DISLODGED AND COMING UP THROUGHOUT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | ADDITIONAL SMOKE DETECTOR NEEDED. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WATER DAMAGE AND BLACK RESIDUE ON WALLS IN BASEMENT. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | LOAD SIDE OF METER PIPED IN EMT CONTRARY TO 18-27-230,43 | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | DEFECTIVE OUTLETS THROUGHOUT 1ST FLOOR. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | VERY STRONG ODORS THROUGH OUT FIRST FLOOR APARTMENT (18-29-705.1 THROUGH 16)(7-28-060)(18-29-301.3) | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPLACE HOUSE DRAIN PIPING | (11-16-020)(18-29-702.4) | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | (13-196-580-A)(13-168-060 THRU 13-168-070)(4-332-010-100) | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | (18-29-106.2)(13-168-060 THRU 13-168-070)(4-332-010-100) | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIR SYSTEM: MISSING HANDRAILS, GRADE TO 1ST, AND GRADE TO BASEMENT | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | PROVIDE DEADLOCK FOR ENTRANCE | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR DOOR MISSING:VESTIBULE PROVIDE SOLID CORE DOOR-SECOND FLOOR HALLWAY | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | REPAIR FRONT INTERIOR STAIR SYSTEM:MISSING BALLUSTERS AND SECTIONS OF HANDRAILS; TREADS AND RISERS LOOSE AND UNATTACHED AT WINDERS | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REPAIR GARAGE:WORN ROOF, ROTTED HEADERS AND JOISTS | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE INSPECTION TO DETERMINE BASEMENT OCCUPANCY AND INTERIOR VIOLATIONS | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | FIEL BUILDING REGISTRATION WITH DOB | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | D & H REPLACE DEFECTIVE SERVICE, CONDUCTORS IMPROPER SIZE FOR 200 AMP SERVICE. PER PERMIT 8/24/1988 EL7798585, 3/14/2013 #100477635 | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | EXTERIOR DOOR AND FRAME RESET | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | ALL SERVICE CONDUCTORS FOR 4 METERS IN ONE CONDUIT | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE BROKEN, PAINTED OVER, BURNT OUT RECEPTACLES THROUGHOUT BLDG 1ST FLR. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | (KO FILLERS) | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | LIGHT FIXTURE IN BSMT | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
CORD TO FIXTURE | D & H BSMT, LIVE WIRE | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
DETERIORATED CONDUCTORS | REPLACE CONDUCTORS WITH DAMAGED OR DETERIORATED INSULATION (FEEDERS) NEW PROPER SIZE CONDUCTORS | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
SUPPLEMENTAL GROUND | NOT DETECTED IN THE BSMT | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VEFY DETECTORS AND INTERIOR CONDITIONS. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR**************** | OBTAIN ELECTRICAL PERMIT AND LICENSED ELECTRICIAN TO PERFORM WORK | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
STRAP SERVICE CONDUIT | D & H, RE-ATTACH CONDUIT TO BLDG | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH PARAPET WALLS - SPALLING BRICKS, ERODED MORTAR JOINTS. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION WINDOWS - MISSING ALUMINUM CAPPING. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - ROTTED OVERHEAD DOOR BEAM AND ROOF JOIST, EXTERIOR WALL - ERODED MORTAR JOINT. PERMIT REQUIRED TO REPAIR OR REPLACE GARAGE. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
PARAPET | EAST AND WEST PARAPET - SPALLED, DETERIORATING BRICK, WASHED OUT MORTAR AND STEP/STRESS FRACTURES THRU-OUT ENTIRE ELEVATION. 14X-3-303.6, 14X-3-305.1.1PERMITS REQUIRED. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | 3 STORY MASONRY BUILDING. GARAGE OPEN - DANGEROUS AND HAZARDOUS CONDITION. WALL SECTION MISSING, OVERHEAD DOORS MISSING, DEEPLY SPALLED DETERIORATING BRICK, SEVERE WASHED OUT MORTAR, STEP/STRESS FRACTURES THRU-OUT ENTIRE GARAGE. ROOF PARTIALLY MISSING/COLLAPSED. 14X-3-303.1.1, 14X-3-305.1.1 AND 14B-4-406.1PLANS AND PERMITS REQUIRED TO REBUILD. PERMIT REQUIRED TO DEMO. | 6649 S STEWART AVE | COMPLAINT | FAILED | View |