PIN: 16131080410000
Property Address: 2916 W WILCOX ST
City - Zip: CHICAGO - 60612
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77102
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 34 Violations
Violation Inspector Comments Address Category Status View
REPAIR COPING WEST ELEVATION COPING IS CRACKED 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR LINTELS (SR#0700022173) SOUTH-LINTEL AT BASEMENT DOOR IS RUSTED NORTH-LINTEL ABOVE WINDOW AND DOOR ON 2ND FLOOR IS RUSTED 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH-CONCRETE LEDGE AT STAIRS IS CHIPPED 2916 W WILCOX ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE SOUTH DEBRIS IN FRONT YARD NORTH GARBAGE IN REAR YARD 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL WEST EAST ELEVATIONS OPEN MORTAR JOINTS CRACKS IN EXTERIOR WALL 2916 W WILCOX ST COMPLAINT FAILED View
CHIMNEY WEST AND EAST ELEVATIONS OPEN MORTAR JOINTS CHIMNEY IS LEANING ACQUIRE PERMITS FOR REPAIR OR REPLACEMENT 2916 W WILCOX ST COMPLAINT FAILED View
REPUTTY WINDOW PANES WEST ELEVATION-TRIM AROUND WINDOW IS WEATHERED AND DETERIORATING 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR WINDOW SILLS NORTH ELEVATION WINDOW SILLS ARE DETERIORATING (2ND FLOOR) 2916 W WILCOX ST COMPLAINT FAILED View
MAINTAIN WINDOW NORTH ELEVATION-2ND FLOOR FRAME AROUND WINDOW IS ROTTING 2916 W WILCOX ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS NORTH ELEVATION-2ND FLOOR PLYWOOD OVER WINDOW 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME NORTH ELEVATION-2ND FLOOR DOOR JAMB IS ROTTING 2916 W WILCOX ST COMPLAINT FAILED View
INSTALL DEAD BOLT LOCK NORTH ELEVATION-2ND FLOOR DEADBOLT IS MISSING 2916 W WILCOX ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY NORTH REAR GATE IS PADLOCKED AND KEYED ON BOTH SIDES 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH-REAR PORCH UNDERSIZED 4X4 BEAMS AREA IMPROPERLY ATTACHED TO COLUMNS OPEN BEAM POCKETS UNDERSIZED 4X6 COLUMNS BEAR DIRECTLY ON FOUNDATION LEDGER BOARD IS ATTACHED TO EXTERIOR WALL WITH NAILS ONLY RIM JOISTS ARE PULLING AWAY FROM LEDGER BOARDS AT BASEMENT,UNDERSIZED 2X6 JOISTS AREA USED OVER 14 FOOT SPANS JOIST HANGERS ARE MISSING STRINGERS ARE INADEQUATELY SUPPORTED AT 4X4 COLUMN EXCESSIVE GAP BETWEEN EXTERIOR WALL AND STAIRS FROM 1ST TO 2ND FLOOR RAILS ARE LESS THAN 42 INCHES TALL AND ARE ATTACHED TO EXTERIOR WALL WITH NAILS ONLY PICKET5S ARE MISSING RAILS ON 1ST FLOOR ARE SPLITTING (TOP RAIL) AND WEATHERED ON 2ND FLOOR HANDRAILS AT 2ND FLOOR ARE WEATHERED AND DETERIORATING HANDRAILS FROM GRADE TO 1ST FLOOR ARE DEFLECTING ON 2ND FLOOR 13-15 INCH GAP EXISTS FROM BOTTOM OF HANDRAIL TO THE TOP OF TREAD TREADS AND DECKING ARE DETERIORATING CEILING HEIGHT OF INTERMEDIATE LANDING IS 63 INCHES SUBMIT PLANS AND PERMITS FOR REPAIR OR REPLACEMENT 2916 W WILCOX ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE INTERIOR UNVERIFIED DETECTORS OR OCCUPANCY 2916 W WILCOX ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO MANAGEMENT SIGN POSTED 2916 W WILCOX ST COMPLAINT FAILED View
NO POSTED ADDRESS NO ADDRESS POSTED 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH 2 LEVELS UNDERSIZED PORCH COLUMNS AND BEAMS (4"X6") REQUIRED DIMENSION FOR STRUCTURAL MEMBERS IS (6"X6") ALSO PORCH BANISTERS ARE TOO LOW (36") REQUIRED HEIGHTS (42") ALSO NO BOLTS AT FOLLOWING CRITICAL CONNECTIONS NEWEL POSTS; RIM BEAMS; UPPER STAIR CASES ALSO MISSING BANISTER PICKETS 2916 W WILCOX ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR ORIGINAL BASEMENT STORAGE ALTERED TO NOW EXISTING LIVING SPACE THAT IS DUPLEX WITH THE 1ST FLOOR. BASEMENT PARTITION WALLS FORM ROOMS THAT INCLUDE 3 BEDROOMS AND 1 BATHROOM NO PLANS PERMITS, OR ZONING AUTHORIZATION 2916 W WILCOX ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT 1ST NO SMOKE DETECTORS 2916 W WILCOX ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT 1ST NO CARBON MONOXIDE DETECTORS 2916 W WILCOX ST COMPLAINT FAILED View
PRV VALVE ON CW INLET TO HWHTR SEPARATE VALVES FOR HOT WATER HEATERS SUPPLY LINES 2916 W WILCOX ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REPLACE PLASTIC DISCHARGE PIPES ON WATER HEATERS 2916 W WILCOX ST COMPLAINT FAILED View
INSTALL FIXTURES PROPERLY DISCHARGE WASTE FROM SUMP PIT IN BASEMENT TO HOUSE SEW NOT VACANT LOT NEXT DOOR 2916 W WILCOX ST COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHTS FIXTURES EXTERIOR OF BUILDING HALLWAY BASEMENT INSTALL PUBLIC PANEL SEPARATE CIRCUIT FOR SEPARATE DWELLING UNIT 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR COPING WEST ELEVATION COPING TILES SOME SECTIONS MISSING. 2916 W WILCOX ST COMPLAINT FAILED View
CONNECT DOWNSPOUT TO SEWER WEST ELEVATION DOWNSPOUT DRAINING INTO AJACENT LOT. 2916 W WILCOX ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I.D SIGN POSTED. 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR SILL NORTH ELEVATION-2ND FLOOR THRESHOLD IS ROTTING CONCRETE SILL IS DETERIORATING 2916 W WILCOX ST COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR NORTH ITEMS ARE STORED UNDERNEATH STAIRS 2916 W WILCOX ST COMPLAINT FAILED View
REPAIR OR REPLACE NORTH ELEVATION GUTTERS ARE BENT AND RUSTED 2916 W WILCOX ST COMPLAINT FAILED View
BUILDING IN DISREPAIR NORTH REMOVE PARTIAL MASONRY WALL ON REAR FOUNDATION ACQUIRE PERMITS FOR DEMOLITION 2916 W WILCOX ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY 2ND FLOOR APARTMENT 2916 W WILCOX ST COMPLAINT FAILED View
FOUNDATION, ADEQUATELY SUPPORT WEST FOUNDATION WALL IS CRACKED AND DETERIORATING 2916 W WILCOX ST COMPLAINT FAILED View