REPAIR EXTERIOR WALL | NORTH AND SOUTH WALLS-SPALLING BRICKS AND WASHES OUT MORTAR | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR OPEN NORTH PORCH SYSTEM-2ND AND 4TH LANDING LOOKOUT SUPPORT ROTTED AT COLUMN CONNECTION ALSO, COLUMN AREA'S ROTTED-2ND TO 3RD OUTER NORTH HANDRAIL ROTTED AND LOOSE AT BOTTOM RAIL ALL AREA'S REQUIRED TO HAVE METAL HARDWARE GUARD AND HANDRAILS-LOOKOUT AT UPRIGHTS-FLOOR JOSTS-MISSING HARDWARE-GAURD AND HAND RAILS WEAK AND TOO LOW-PLANS AND PERMIT REQUIRED FOR ALL REPAIRS AND UPGRADES SHOWN IN DETAIL ON APPROVED PLAND BEFORE WORK IS PERFORMED | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQUIRED | PLANS AND PERMIT BEFORE WORK IS DONE | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT REQUIRED FOR ALL PORCH REPAIRS ON REPLACEMENT OF PORCH | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR 4 STORY WOOD PORCH IS DANGEROUS AND HAZARDOUS ROTTED TREADS AND RISERS 3RD TO 4TH, 4TH HAS LOOSE GUARD RAIL - ROTTED OUT COLUMN AT 3RD, STRINGERS NOT BOLTED, 2X8 JOISTS OVER SPANNED AT 11' BEAMS TO COLUMNS MISSING BOLTS, BOTTOM RAILS OF GUARDRAILS DEFLECT 2" TO 4" UNKNOWN FOUNDATIONS, PLANS AND PERMITS FOR REPLACEMENT OF PORCH, MOST WOOD ON PORCH IS ROTTED. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH EAST STAIRWAY GRADE TO BASEMENT MISSING HANDRAIL. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | NORTH EAST GUARDRAIL AROUND BASEMENT MISSING PICKETS. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR ROOF STRUCTURE | REAR PORCH ROOF SHEATING ROTTED OUT WITH HOLES. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILING MISSING FIRE RATING THROUGHOUT. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH BASEMENT FOUNDATION WALL MISSING MORTAR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
COVER OUTLETS AND JBS | BASEMENT UNDER BEAUTY SALON SEVERAL OPEN ELECTRICAL BOXES LARGE FIRE HAZARD. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT LAUNDRY ROOM MISSING CARBON MONOXIDE DETECTOR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT LAUNDRY ROOM MISSING SMOKE DETECTOR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | NORTH EAST BASEMENT AS FURNACE ROOM MISSING SMOKE DETECTOR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | NORTH EAST BASEMENT GAS FURNACE ROOM MISSING CARBON MONOXIDE DETECTOR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | NORTH EAST EXTERIOR BASEMENT DOOR NEEDS TO BE RESET IN FRAME BROKEN JAMB - LOOSE HINGES. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
ADD RECEPTACLES | NORTH EAST BASEMENT EXTENSION CORD WIRING FIRE HAZARD. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
PIGEONS-NESTING | NORTH DECK IN BETWEEN BUILDINGS AT 4TH HAS PIGEON FOWLING. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | BEAUTY SALON AT 1ST HAS EXIT SIGN LIGHTS OUT IN FRONT AND REAR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | BASEMENT HAS LOOSE INSULATION HANGING DOWN FROM CEILING . | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT CLUTTER AND GARBAGE THROUGHOUT. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | ALL METAL RAILS AT DECKS IN BETWEEN BUILDING SECTIONS AT NORTH HAVE PICKET SPACING GREATER THAN 4". 2ND THRU 4TH. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | BASEMENT STAIRS SOUTH ENTRANCE WATER AT BOTTOM OF STAIRS AT BASEMENT FLOOR. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | FOR ALL REPAIRS,REMOVING PLASTER IN THE BATHROOMS AND THE KITCHENS AND REPLACING WITH DRYWALL.PERMIT #100462604 ISSDUED 10-15-12 - STOP ORDER FEES PAID | 1501 N SEDGWICK ST | COMPLAINT | CLOSED | View |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL A PROPER PERMIT HAS BEEN OBTAINED,SEC.13-32-035,13-12-080.PERMIT #100462604 ISSDUED 10-15-12 - STOP ORDER FEES PAID | 1501 N SEDGWICK ST | COMPLAINT | CLOSED | View |
WORK REQUIRES GC LICENSE | WORK REQUIRES A G.C. LICENSE.PERMIT #100462604 ISSDUED 10-15-12 - STOP ORDER FEES PAID | 1501 N SEDGWICK ST | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | FOR ALL REPAIRS,REMOVING PLASTER IN THE BATHROOMS AND THE KITCHENS AND REPLACING WITH DRYWALL. | 1501 N SEDGWICK ST | COMPLAINT | FAILED | View |
WORK REQUIRES GC LICENSE | WORK REQUIRES A G.C. LICENSE. | 1501 N SEDGWICK ST | COMPLAINT | FAILED | View |
PROVIDE | FIRE ESCAPE RUSTEDPROVIDE PER SECTION 14A-6-603.3, 14A-6-603.3.1, 14A-6-603.3.2, 14A-6-603.3.3, 14A-6-603.3.4, 100% HANDS-ON CRITICAL EXAM OF FIRE ESCAPE AND ALL EXPOSED METAL. SUBMIT TO: DEPARTMENT OF BUILDINGS, ATTN: CODE-COMPLIANCE GROUP, 2045 W. WASHINGTON 60612. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR PORCH ALL GUARDRAILS RUSTED. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | EXIT SIGNS OUT | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH DECK BEAM POCKETS MISSING PROPER STRAPS OR ANCHORS, OBTAIN PERMIT FOR ALL REPAIRS. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS WINDOWS ROTTED FRAMES VARIOUS LOCATIONS. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS PARAPET WALLS SEVERE WASHED OUT MORTAR AND SPALLING BRICK.SOUTH ELEVATION WOOD WALL DAMAGED, ROTTED.OBTAIN MASONRY PERMIT FOR ALL REPAIRS. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR ALL YEARS 1990-2006 | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT WEST ENTRY DOOR-RESET | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | MIDDLE STAIRWAY GRADE TO BASEMENT - BEAUTY SALON MISSING HANDRAIL. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | WEST FRONT STAIRWAY BY SKY LIGHT CEILING HAS BUBBLED PLASTER BOARD. | 1501 N SEDGWICK ST | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL A PROPER PERMIT HAS BEEN OBTAINED,SEC.13-32-035,13-12-080. | 1501 N SEDGWICK ST | COMPLAINT | FAILED | View |
SEND EX. METAL LETTER | EXPOSED METAL LETTER | 1501 N SEDGWICK ST | COMPLAINT | PASSED | View |
PROTECT METAL MEMBERS | PROTECT METAL MEMBERS | 1501 N SEDGWICK ST | COMPLAINT | PASSED | View |