The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR CORNICE | FRONT ELEVATION /STONE CORNICE - PEELING PAINT. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION /EXTERIOR WALL - LOOSE PARGED, WASHED OUT MORTAR ABOVE 2ND. FL. WINDOWS.GROUND LEVEL /FRACTURED LOOSE, WASHED OUT MORTAR. MORTAR | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /ROOF SHINGLES - WORN-OFF, CURLED, MISSING. [COVERED WITH TARP]GARAGE /GUTTERS AND DOWNSPOUTS - MISSING.GARAGE /EAST ELEVATION - MISSING VINYL SIDING. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FRONT ELEVATION /SCREEN FENCE - LOOSE, MISSING TOP RAIL, GATE DAMAGED AND OFF HINGES. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | FRONT ROOF OVER 1 STORY EXTERIOR WOOD PORCH;ROOF STRUCTURE /LOOSE AND PULLING AWAY FROM EXTERIOR WALL;PLANS AND PERMIT REQUIRED TO REPLACE ROOF STRUCTURE. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1 STORY WOOD PORCH;FOUNDATION /COLUMNS COVERED UP BY PLYWOOD AROUND DECK STRUCTURE - FOUNDATION STATUS UNKNOWN;COLUMNS /COVERED UP BY PLYWOOD AROUND DECK STRUCTURE - UNABLE TO INSPECT CONDITIONS. LEDGER BEAM /COVERED UP BY PLYWOOD AROUND DECK STRUCTURE - UNABLE TO INSPECT CONDITIONS. BEAMS /ROOF HEADER - ROTTING.STRINGERS /COVERED UP BY PLYWOOD AROUND DECK STRUCTURE - UNABLE TO INSPECT CONDITIONS. STAIRS / TREADS [INCLUDING NOSING] - ONLY 9 1/4 INCHES WIDE; TREADS AND RISERS - WORN-OUT, CRACKED, BROKEN, ROTTING, WEAK;DECKING /DECK BOARDS - ROTTING, BUCKLED UP;RAILINGS /GUARD RAILING SECTIONS - ONLY 36 INCHES HIGH; GUARD RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS ONLY; STAIR RAILING SECTIONS - LOOSE AND PULLING, FASTENED TO COLUMNS WITH NAILS ONLY; PLANS AND PERMIT REQUIRED TO REPLACE FRONT PORCH; | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 2 STORY EXTERIOR WOOD PORCH.FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN.COLUMNS /6X6 COLUMNS STACKED UP ON TOP OF 6X6 BEAMS; COLUMNS ARE ROTTING AT ALL CONNECTIONS; COLUMNS HAVE SPLITS /CHECKS UP TO 24 INCHES LONG; COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 12 INCHES - FASTENED WITH NAILS ONLY; 4X4 COLUMNS - SPACED UP TO 8 FOOT APART;LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS ONLY - PULLING AWAY; WITH GAPS BETWEEN THEM OF UP TO 2 1/2 INCHS;BEAMS /ROTTING, SAGGING AT FIRE CUT; PULLING OUT OF FIRE CUTS; IMPROPERLY SUPPORTED AT FIRE CUTS; BEAMS TOE NAILED TO COLUMNS; BEAMS HAVE SPLITS UP TO 22 INCHES LONG; DECK JOISTS /UNDERSIZED 2X8 DECK JOISTS SPAN 14 FEET; JOISTS SPACED UP TO 21 INCHES O.C. (APART); JOISTS - SCABBED; JOISTS FASTENED TO HEADERS, WITH NAILS ONLY; STRINGERS /OVERCUT, ROTTING, CRACKED, BROKEN; UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER, COLUMNS AND DECK, WITH NAILS ONLY; STRINGERS WEAK; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALLS, ARE PULLING AWAY; WITH GAPS BETWEEN THEM OF UP TO 11/2 INCHS;STAIRS /ONLY 28 INCHES WIDE; TREADS [INCLUDING NOSING] - ONLY 6 1/2 INCHES WIDE; RISERS - 9 1/4 INCHES HIGH; TREADS AND RISERS - WORN OUT, CRACKED, BROKEN, ROTTING, WEAK, MISSING;DECKING /DECK BOARDS ROTTING, BUCKLED UP;RAILINGS / GUARD AND STAIR RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; GUARD RAILING SECTIONS - ONLY 36 INCHES HIGH; STAIR RAILING SECTIONS - ONLY 26 INCHES HIGH; RAILING SECTION MEMBERS [TOP AND BOTTOM RAILS, PICKETS] - ROTTING, LOOSE, CRACKS, BROKEN;PLANS AND PERMIT REQUIRED TO REPLACE D&H PORCH. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ELEVATION /EXTERIOR DOORS - BURGLAR GATES. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING ¿ ENTRY REFUSED. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY.UNABLE TO INSPECT INTERIOR STAIRWAY. | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP WORK UNTIL PERMIT IS OBTAINED SECTION 14A-4-411 | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS EXCAVATING BASEMENT OER ONE FOOT DEEPER REMOVED LATH & PLASTER FROM FIRST & 2ND FLOOR | 7216 S PERRY AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 7216 S PERRY AVE | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 7216 S PERRY AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 7216 S PERRY AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 7216 S PERRY AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 7216 S PERRY AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 7216 S PERRY AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 7216 S PERRY AVE | COMPLAINT | CLOSED | View |