Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER NAME OF VACNT BLDG | VIOLATIONS CLOSED WHEN INSPECTION IS CLOSED OR CANCELLED | 7218 S PERRY AVE | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR 2 STORY EXTERIOR WOOD PORCH WITH ROOF.FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN.COLUMNS /6X6 COLUMNS STACKED UP ON TOP OF 6X6 BEAMS; COLUMNS ARE ROTTING AT ALL CONNECTIONS; COLUMNS HAVE SPLITS /CHECKS UP TO 30 INCHES LONG; COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 12 INCHES - FASTENED WITH NAILS ONLY; 4X4 COLUMNS - SPACED UP TO 8 FOOT APART;LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS ONLY - PULLING AWAY; WITH GAPS BETWEEN THEM OF UP TO 1 INCH;BEAMS /ROTTING, SAGGING AT FIRE CUT; PULLING OUT OF FIRE CUTS; IMPROPERLY SUPPORTED AT FIRE CUTS; BEAMS TOE NAILED TO COLUMNS; BEAMS HAVE SPLITS UP TO 24 INCHES LONG; BEAM POCKETS LEFT WITH VOILDS, MORTAR MISSING;DECK JOISTS /UNDERSIZED 2X8 DECK JOISTS SPAN 14 FEET; JOISTS SPACED UP TO 21 INCHES O.C. (APART); JOISTS - SCABBED; JOISTS FASTENED TO HEADERS, WITH NAILS ONLY; STRINGERS /OVERCUT, ROTTING, CRACKED, BROKEN; UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER, COLUMNS AND DECK, WITH NAILS ONLY; STRINGERS WEAK; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALLS, ARE PULLING AWAY; WITH GAPS BETWEEN THEM OF UP TO 1 INCH;STAIRS /ONLY 30 INCHES WIDE; TREADS [INCLUDING NOSING] - ONLY 9 1/2 INCHES WIDE; TREADS AND RISERS - WORN OUT, CRACKED, BROKEN, ROTTING, WEAK;DECKING /DECK BOARDS ROTTING, BUCKLED UP;RAILINGS / GUARD AND STAIR RAILING SECTIONS - LOOSE AND PULLING; GUARD RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS ONLY; STAIR RAILING SECTIONS - LOOSE AND PULLING, FASTENED TO COLUMNS WITH NAILS ONLY; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; GUARD RAILING SECTIONS - ONLY 36 INCHES HIGH; RAILING SECTION MEMBERS [TOP AND BOTTOM RAILS, PICKETS] - ROTTING, CRACKES, BROKEN;PLANS AND PERMIT REQUIRED TO REPLACE D&H PORCH. | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1 STORY WOOD PORCH;FOUNDATION /BASES UNDER (4) 2X4'S ONLY NAILED TOGETHER) SETTLING DOWN, LOOSE (WITH SETTLEMENT OF 1 1/2 INCHES). FOUNDATION STATUS UNKNOWN;COLUMNS (4) 2X4'S ONLY NAILED TOGETHER) WITH NO BASES; LEDGER BEAM /FASTENED TO BUILDING EXTERIOR WALL WITH NAILS ONLY;BEAMS /UNDERSIZED 2X4'S SPAN 7 FEET;STRINGERS / UPPER ENDS OF STRINGER INADEQUATELY SUPPORTED AT HEADER JOISTS WITH NAILS ONLY;STAIRS / TREADS [INCLUDING NOSING] - ONLY 9 1/4 INCHES WIDE; TREADS AND RISERS - WORN OUT, CRACKED, BROKEN, ROTTING, WEAK;DECKING /DECK BOARDS - ROTTING, BUCKLED UP;RAILINGS /GUARD RAILING SECTIONS - ONLY 36 INCHES HIGH; GUARD RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS ONLY; STAIR RAILING SECTIONS - LOOSE AND PULLING, FASTENED TO COLUMNS WITH NAILS ONLY; PLANS AND PERMIT REQUIRED TO REPLACE FRONT PORCH; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | FRONT ROOF OVER 1 STORY EXTERIOR WOOD PORCH;ROOF STRUCTURE /LOOSE AND PULLING AWAY FROM EXTERIOR WALL;REAR ROOF OVER 2 STORY EXTERIOR WOOD PORCH;ROOF STRUCTURE /UNDERSIDE - ROTTING, BUCKLED;PLANS AND PERMIT REQUIRED TO REPLACE FRONT AND REAR ROOF STRUCTURES; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT ELEVATION /STONE CORNICE - WASHED OUT MORTAR, SHIFTING SEGMENTS OF STONEWORK; PEELING PAINT; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | SOUTH ELEVATION /PARAPET WALL -LOOSE BRICK WITH WASHED OUT MORTAR; BROKEN AND MISSING COPPING; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 2ND. FL. APT. - SMOKE DETECTOR OUT OF SERVICE; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY - MISSING SMOKE DETECTOR; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FL. APT. CARBON MONOXIDE DETECTOR - OUT OF SERVICE; | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | BUILDING THROUGHOUT - MICE DROPPINGS OBSERVED IN 2ND FL. APT. | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION, WASHED OUT MORTAR, ALL ELEVATIONS | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY MISSING CAP | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | CORNICE, FRONT ELEVATION SOUTH SIDE OF BLDG, PULLING AWAY FROM BUILDING, DANGEROUS | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH SYSTEM, TREADS ROTTED, RAILINGS LOOSE, GUARDRAILS LESS THAN 42" HANDRAILS LESS THAN 36", JOIST ROTTED DECKING ROTTED FOOTINGS MISSING. REAR PORCH, GUARDRAILS LEES THAN 42" HANDRAILS LESS THAN 36", COLUMNS BUTT JOINTED, RAILINGS LOOSE, JOIST UNDERSIZED NO JOIST HANGERS STRINGERS NOT PROPERLY ATTACHED TO COLUMNS | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | REAR PORCH ROOF, SHEATHING WATER DAMAGED, SOUTH BEAM POCKET OPEN LEDGER, NO ANCHOR BOLTS | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE WRECK OR REPAIR, PARAPET WALL, BROKEN & FALLING BRICK DANGEROUS, WASHED OUT MORTAR EXTERIOR WALLS ALL LEVELS, ROOF SHEATHING ROTTED, OVERHEAD & SERVICE DOORS & EXTERIOR TRIM, PEELING PAINT & ROTTED | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT BEFORE PERFORMING WORK | 7218 S PERRY AVE | COMPLAINT | FAILED | View |
OBTAIN OR POST PERMIT | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 7218 S PERRY AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 7218 S PERRY AVE | COMPLAINT | CLOSED | View |