Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 8:57 PM
PIN: 11314140220000
Property Address: 1701 W ALBION AVE
City - Zip: CHICAGO - 60626
2023 Property Class: 315
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75031
2023 Tax District: 75001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 56 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY TEMPERATURE AT TIME OF INSPECTION, 63.3 F 1701 W ALBION AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE COLD AIR STRONGLY SEEPING THROUGH BACKDOOR AS WELL AS WINDOWS IN KITCHEN 1701 W ALBION AVE COMPLAINT FAILED View
PARAPET EAST ELEVATION/PARAPET-MINOR SPALLED BRICKS AND WASHED OUT MORTAR. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION/-MINOR WASHED OUT MORTAR. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION AND FRONT COURTYARD/WINDOW SILLS/- WASHED OUT MORTAR. 1701 W ALBION AVE PERIODIC FAILED View
PARAPET EAST ELEVATION/PARAPET-MINOR SPALLED BRICKS AND WASHED OUT MORTAR. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION/-MINOR WASHED OUT MORTAR. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION AND FRONT COURTYARD/WINDOW SILLS/- WASHED OUT MORTAR. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR EXTERIOR STAIR REAR EXTERIOR STAIR-RAILINGS TOO LOW. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR CORNICE NORTH ELEVATION, CORNICE - OPEN MORTAR JOINTS SOME SECTIONS SHIFTING OUT. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR WINDOW SILLS NORTH ELEVATION, SILLS - OPEN MORTAR JOINTS SOME SILLS CRACKED. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 1701 W. 3RD FLOOR - KITCHEN CEILING - WATER DAMAGED. 1701 W ALBION AVE PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY 1707,1703 & 1701 STAIRWAYS - TENANT STORAGE AT STAIR LANDINGS 1701 W ALBION AVE PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED GRADE 1705 1/2 STAIRWAY - EXIT SIGN BULB OUT 1701 W ALBION AVE PERIODIC FAILED View
PARAPET EAST SIDE COURTYARD, PARAPET - STONEWORK OPEN MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID BASEMENT LAUNDRY ROOM - MISSING CARBON MONOXIDE ALARM.(14X-5-504.9, 14B-9915.1.1, 14B-9-915.2, AND 14R-11-1105)CB132046 ) 1701 W ALBION AVE PERIODIC FAILED View
REPAIR DOOR HARDWARE 1701 1/2 VESTIBULE DOOR - MISSING DOOR KNOB 1701 W ALBION AVE PERIODIC FAILED View
CARPETING 1707 STAIRWAY - LOOSE AND TORN CARPETING 1701 W ALBION AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM -- EAST ELEVATION, NORTH 3 STORY OPEN WOOD PORCH SYSTEM. 3RD FLOOR DECK BAORDS ROTTEN WITH HOLES. OUTSIDE RAILING 3RD FLOOR CENTER RAILING POST ROTTEN AND BROKEN. INSIDE RAILINGS ONLY 32 INCHES HIGH. 2ND FLOOR RAILING CENTER SUPPORT 2X4 ROTTING WITH PULLING TOE NAIL CONNECTIONS. -- EAST ELEVATION, SOUTH 3 STORY OPEN WOOOD PORCH SYSTEM - 1ST FLOOR CRACKED FLOOR JOIST. SOME JOIST ROTTEN AT ENDS WITH SCABBING. CENTER 4X4 POST CRACKED WITH NAILED BUTT JOINT SPLICE, NAILS RUSTED AND PULLING. STRINGER WEAK CONNECTION AT LANDING TO 2ND FLOOR SAGGING AND PULLING FROM 4X4 COLUMN. 2ND FLOOR BEAM, WEAK CONNECTION TO RIM JOIST. 2ND FLOOR STRINGER ROTTING AND SPLITTING WITH LOOSE RISERS AND TREADS. 2ND FLOOR DECK BOARDS ROTTEN AT ENDS. 3RD FLOOR RAILING WEAK CONNECTION TO WALL. SOME TREADS LOOSE. SOME RAILINGS HAVE LARGE 7 INCH GAP UNDER PICKETS. 3RD FLOOR 2X10 RIM JOISTS ROTTEN. -- SOUTHWEST REAR OPEN WOOD PORCH SYSTEM. STRINGERS SPLITTING, FLOOR JOISTS ROTTEN AT ENDS, SOME TREADS LOOSE. SOME DECK BOARDS ROTTEN AT ENDS. -- WEST ELEVATION, SOUTH 3 STORY OPEN WOOD PORCH SYSTEM - 2ND AND 3RD FLOOR BEAM METAL SUPPORT BRACKET - LOOSE BOLTS. STAIR STRINGERS NOT PROPERLY SUPPORTED AT TOP WITH SCABBED WOOD PEICES AT POST CONNECTIONS. DECK JOISTS UNDER SIZED WITH SINGLE 2X8 SPAN 13 FOOT 4 INCHES. COLUMN SPLICE CONNECTIONS WITH 10 INCH LAP SPLICE JOINTS OVER CUT WITH COLUMNS SPLITTING. WEST ELEVATIOIN, NORTH 3 STORY OPEN WOOD PORCH SYSTEM - DECK JOISTS UNDER SIZED WITH SINGLE 2X8 SPAN 13 FOOT 4 INCHES. 3RD FLOOR BEAMS AND ROOF BEAMS - MULTIPLE BEAMS CRACKED. SOME TREADS WEAK. -- PLANS AND PERMT REQUIRED TO REPAIR ALL PORCH SYSEMS. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR COPING EAST,WEST AND SOUTH ELEVATIONS - MISSING COPINGS 1701 W ALBION AVE PERIODIC FAILED View
REPAIR FLOOR GRADE 1703&705 VESTIBULES - LOOSE AND MISSING FLOOR TILES. 1701 W ALBION AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS.ENTRY TO STAIRWAYS AND LAUNDRY ROOM ONLY 1701 W ALBION AVE PERIODIC FAILED View
ILLUMINATE PUBLIC STAIR/HALL ALL STAIRWAYS - BULBS OUT AT VARIOUS FLOORS THRU-OUT 1701 W ALBION AVE PERIODIC FAILED View
ROACHES 1701 W. 3RD FLOOR - ROACHES 1701 W ALBION AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR EAST AND WEST ELEVATIONS PORCHES, 2X4 FRAMED WALLS ATTACHED TO EXTERIOR MASONARY WALLS ENCLOSED WITH PLEXI GLASS. COURTYARD ALL LEVELS BATHROOM WINDOWS REMOVED AND PLYWOOD AND SIDDING INSTALLED WITH VENTS.NO PERMIT OBTAINED, NO PLAN SUBMITTED. 1701 W ALBION AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO ONWER I.D SIGN POSTED. 1701 W ALBION AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS INTERIOR OF 1701 W/ SMOKE DETECTOR CHEERPING. 1701 W ALBION AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO ONWER I.D SIGN POSTED. 1701 W ALBION AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS INTERIOR OF 1701 W/ SMOKE DETECTOR CHEERPING. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE NORTH ELEVATION 17011/2 GLASS COMMON ENTRY DOOR PANIC LOCK WON'T OPEN(FIRE HAZARD). 1701 W ALBION AVE PERIODIC FAILED View
REPAIR COPING NORTH ELEVATION COURTYARD COPING STONES WASHED OUT MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE 1707 HALLWAY SOME ENTRY DOORS MISSING PEEPHOLES. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION AT GRADE SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2014 ANNUAL INSPECTION. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM 1701 & 1705 STAIRWAYS - LOOSE TREADS AT VARIOUS LOCATIONS 1701 W ALBION AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS INTERIOR OF 1701 W/ SMOKE DETECTOR CHEERPING. 1701 W ALBION AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS BASEMENT LAUNDRY ROOM - MISSING SMOKE ALARM.14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, AND 14R-11-1104 1701 W ALBION AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1701 1/2 AND 1707 STAIRWAY - BROKEN WINDOWS 1701 W ALBION AVE PERIODIC FAILED View
MAINTAIN PROJECTIONS WEST SIDE COURTYARD, 1705 1/2 ENTRY STONE ORNAMENTAL PROJECTIONS - OPEN MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 1701-1/2 & 1705-1/2 - STAIRWAYS - PEELING PAINT, HOLES AT WALLS AT VARIOUS LOCATIONS. 1701 W ALBION AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS INTERIOR OF 1701 W/ SMOKE DETECTOR CHEERPING. 1701 W ALBION AVE PERIODIC FAILED View
PARAPET EAST SIDE COURTYARD, PARAPET - STONEWORK OPEN MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST SIDE COURTYARD, 3RD FLOOR - WINDOW BROKEN. 1701 W ALBION AVE PERIODIC FAILED View
MAINTAIN PROJECTIONS WEST SIDE COURTYARD, 1705 1/2 ENTRY STONE ORNAMENTAL PROJECTIONS - OPEN MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM -- EAST ELEVATION, NORTH 3 STORY OPEN WOOD PORCH SYSTEM. 3RD FLOOR DECK BAORDS ROTTEN WITH HOLES. OUTSIDE RAILING 3RD FLOOR CENTER RAILING POST ROTTEN AND BROKEN. INSIDE RAILINGS ONLY 32 INCHES HIGH. 2ND FLOOR RAILING CENTER SUPPORT 2X4 ROTTING WITH PULLING TOE NAIL CONNECTIONS. -- EAST ELEVATION, SOUTH 3 STORY OPEN WOOOD PORCH SYSTEM - 1ST FLOOR CRACKED FLOOR JOIST. SOME JOIST ROTTEN AT ENDS WITH SCABBING. CENTER 4X4 POST CRACKED WITH NAILED BUTT JOINT SPLICE, NAILS RUSTED AND PULLING. STRINGER WEAK CONNECTION AT LANDING TO 2ND FLOOR SAGGING AND PULLING FROM 4X4 COLUMN. 2ND FLOOR BEAM, WEAK CONNECTION TO RIM JOIST. 2ND FLOOR STRINGER ROTTING AND SPLITTING WITH LOOSE RISERS AND TREADS. 2ND FLOOR DECK BOARDS ROTTEN AT ENDS. 3RD FLOOR RAILING WEAK CONNECTION TO WALL. SOME TREADS LOOSE. SOME RAILINGS HAVE LARGE 7 INCH GAP UNDER PICKETS. 3RD FLOOR 2X10 RIM JOISTS ROTTEN. -- SOUTHWEST REAR OPEN WOOD PORCH SYSTEM. STRINGERS SPLITTING, FLOOR JOISTS ROTTEN AT ENDS, SOME TREADS LOOSE. SOME DECK BOARDS ROTTEN AT ENDS. -- WEST ELEVATION, SOUTH 3 STORY OPEN WOOD PORCH SYSTEM - 2ND AND 3RD FLOOR BEAM METAL SUPPORT BRACKET - LOOSE BOLTS. STAIR STRINGERS NOT PROPERLY SUPPORTED AT TOP WITH SCABBED WOOD PEICES AT POST CONNECTIONS. DECK JOISTS UNDER SIZED WITH SINGLE 2X8 SPAN 13 FOOT 4 INCHES. COLUMN SPLICE CONNECTIONS WITH 10 INCH LAP SPLICE JOINTS OVER CUT WITH COLUMNS SPLITTING. WEST ELEVATIOIN, NORTH 3 STORY OPEN WOOD PORCH SYSTEM - DECK JOISTS UNDER SIZED WITH SINGLE 2X8 SPAN 13 FOOT 4 INCHES. 3RD FLOOR BEAMS AND ROOF BEAMS - MULTIPLE BEAMS CRACKED. SOME TREADS WEAK. -- PLANS AND PERMT REQUIRED TO REPAIR ALL PORCH SYSEMS. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 1705 REAR PORCH LOOSE HANDRAIL RAILS STICKING OUT 2ND FLOOR LANDING. 1701 W ALBION AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS & PERMIT FOR REAR PORCH REPAIRS. 1701 W ALBION AVE PERIODIC PASSED View
REPLCE WINDOW PANES, PLEXGLAS EAST SIDE COURTYARD, 3RD FLOOR - WINDOW BROKEN. 1701 W ALBION AVE PERIODIC FAILED View
STOP LEAKING WATER 1705 REAR PORCH CANOPY LEAKING WATER. 1701 W ALBION AVE PERIODIC PASSED View
SAFE WORKING CONDITIONS RADIATOR NOT HEATING UNIT PROPERLY 1701 W ALBION AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR EXTERIOR STAIR-RAILINGS TOO LOW. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR WINDOW SILLS COURTYARD WINDOW SILLS, OPEN MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR EAST AND WEST ELEVATIONS PORCHES, 2X4 FRAMED WALLS ATTACHED TO EXTERIOR MASONARY WALLS ENCLOSED WITH PLEXI GLASS. COURTYARD ALL LEVELS BATHROOM WINDOWS REMOVED AND PLYWOOD AND SIDDING INSTALLED WITH VENTS.NO PERMIT OBTAINED, NO PLAN SUBMITTED. 1701 W ALBION AVE PERIODIC FAILED View
REPAIR WINDOW SILLS COURTYARD WINDOW SILLS, OPEN MORTAR JOINTS. 1701 W ALBION AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE NORTH ELEVATION COURTYARD STORING BRICKS ON WINDOW SILLS. 1701 W ALBION AVE PERIODIC FAILED View
ROACHES 1701 W. 3RD FLOOR - ROACHES 1701 W ALBION AVE PERIODIC FAILED View