The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | SR#07-02145351-FRONT PORCH ROTTEN DECKING, LOOSE RAIL | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT 2ND BROKEN PANE | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR WALL FIRE DAMAGED,SOUTH TORN SIDING | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | FRONT PORCH ROTTEN GAVES | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH FIRE DAMAGE,BEAM BRUNT AT 1ST, HEADER BRUNT, ROTTEN DECKING, IMPROPER FOOTING LOOSE RAILS 1ST AND 2ND, STACKED COLUMNS, SOUTH COLUMN BRUNT ON ENCLOSER, NO BRACKETS, NO BOLTS OBTAIN PLANS AND PERMITS FOR REPAIRS | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR GATE PAD LOCKED | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR BASEMENT HATCH DOOR ROTTEN | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT PADLOCKED | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PARTLY ENCLOSED PORCH DANGEROUS AND HAZARDOUS, FIRE DAMAGE ON THE SOUTHWEST CORNER LOOK OUT BURNED, 2X6 JOIST BURNED, PART OF 6X6 COLUMN BURNED, INTERMEDIATE LANDINGS 2X6 CONSTRUCTION NO JOIST HANGERS, NO BEAM TO COLUMN CONNECTIONS ON ANY LEVEL, STRINGERS, NO BOLTS TO SUPPORT POST OR BUILDING, GUARDRAILS AT 32" MUST BE AT 42", IMPROPER FOOTINGS FOR ALL COLUMNS, ALL COLUMN BUTT JOINT CONSTRUCTION. PLANS AND PERMITS REQUIRED FOR REPLACEMENT. | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
1HR SEP-D.U. AND REST OF BLDG | UNDER SIDE OF ENCLOSED PORCH SYSTEM WITHOUT PROPER 1HR FIRE RATING OR IN BETWEEN FLRS. PERMITS REQUIRED. | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT PORCH SYSTEM WITH FOLLOWING DEFECTS, ROTTED SUPPORT COLUMNS, ROTTED DECKING, WORN TREADS, PLANS AND PERMITS REQUIRED. | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR FENCE | REAR FENCE TOP RAIL MISSING | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | SECOND FLOOR ALL FIXTURES | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT HAS APPROXIMATELY 1 FOOT OF STOOL AND WATER MUST BE SANITIZED COMPLETE BY | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View |
REPAIR CATCH BASIN | TOP BROKEN | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View |
REPLACE HOUSE DRAIN PIPING | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View | |
OBTN PERMIT FOR PLUMBING WORK | SR#1000263331 | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View | |
REPAIR EXTERIOR WALL | FRONT-EAST ELEVATION-SIDING PULLED AWAY AT SOUTH ELEVATION WALL BULGING AT GRADE,REAR PARTIALY BURNED | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | 2ND FLOOR ALL ELEVATIONS SASHES BROKEN,PROPPED UP THRU OUT APARTMENT WITH JARS AND TOOLS PAINT PEELING ON SASHES | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS ROTTED FRAMES ALL LEVELS PAINT PEELING | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR EAVES | EAST ELEVATION ROTTED FASCIA AND EAVES ABOVE PORCH AND AT ROOF AREA PAINT PEELING ON SAME | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR FENCE/GATE CHAINED AND PADLOCKED | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR DOWNSPOUT | DOWNSPOUTS AND GUTTERS ROTTED/RUSTED WITH HOLES PAINT PEELING ON GUTTERS | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
EXIT THROUGH BEDROOM/BATHROOM | 2ND FLOOR-ENCLOSED PORCH AREA BEING USED FOR BEDROOM | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR, ENCLOSED PORCH AND FRONT STAIRWAY,NO SMOKE DETECTOR | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR-NO CARBON MONOXIDE DETECTORS | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
SCAVENGER SERVICE | FRONT STAIRWAY-LOOSE RIPPED CARPET ON TREADS | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRS RISERS WOOD SPLIT TREADS WEAK UNDER LOAD GUARDRAIL BROKEN AT TOP STEPS SLANTED AT WINDERS | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
COVER OUTLETS AND JBS | UNIT 2-OUTLET COVERS MISSING THRU-OUT LIVING ROOM AND BEDROOMS | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
DEFECTIVE POWER SERVICE | REAR-UNDER PORCH-SERVICE ENTRANCE CABLE HANGING LOOSELY BARB WIRES,FRAYED INSULATION PERMIT REQUIRED (18-27-230-2) | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR AREAWAY WALL | REAR FOUNDATION WALL DANGEROUS LEAKING UNDER PORCH | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | REAR PORCH AREA JUNK AND DEBRIS STORED | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
CLEAN CATCH BASIN | REAR CRACKED SEWER RIM (CATCH BASIN) | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | UNIT-2 LEAK UNDER KITCHEN SINK | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR DOOR FRAME, MULLION | UNIT 2-FRAME AT APARTMENT DOOR SPLIT WOOD | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | UNIT 2-FRONT LIVING ROOM-CEILING BULGING NEAR LIGHT FIXTURE ALSO HOLE IN BATHWALL AROUND FAUCET | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
FLOOR, KIT & BATH NON-ABSORB | UNIT 2-TILES MISSING ON BATH FLOOR | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
INSPECT CONSTRUCTION WORK | NO PLANS AND PERMIT AVAILABLE FOR REAR AND FRONT PORCHES ERECTED NO PERMITS AVAILABLE FOR SECTION OF ENCLOSED REAR PORCH SECTION | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION 2ND FLOOR PANES MISSING | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR APARTMENT- TENANT USING STOVE AS A HEATING DEVICE | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 2ND FLOOR APARTMENT- MIDDLE BEDROOM, WINDOW PANE BROKEN. DRAFTY WINDOW. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 2ND FLOOR APARTMENT- ROOM TEMPERATURE ONLY 56F. HEATING SYSTEM OFF AT TIME OF INSPECTION. NO HEAT PROVIDED. GAS SHUT - OFF. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 2ND FLOOR APARTMENT-HOT WATER SUPPLIED AT 48F ONLY. NO HOT WATER PROVIDED. GAS SHUT- OFF. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION ALUMINUM SIDING MISSING ABOVE 2ND FLOOR WINDOW.WEST ELEVATION IN VARIOUS LOCATIONS WOOD SIDING MISSING WITH EXPOSED SHEATHING. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION BASEMENT STAIRWELL MISSING HANDRAIL. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION 1ST AND 2ND FLOOR WINDOWS BOARDED. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | SOUTH AND NORTHWEST CORNERS DOWNSPOUTS MISSING. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | WEST ELEVATION BASEMENT STAIRWELL RETAINING WALL COLLAPSING. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT FOR PLUMBING | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | INTERIOR NO RESPONCES | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | BASEMENT | 5914 S PRINCETON AVE | COMPLAINT | CLOSED | View |
UNAPPROVED HEATING DEVICE | USING COOKING STOVE TO HEAT APT. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | UNIT 2-LIGHT FIXTURE LOOSELY HANGING IN BATHROOM | 5914 S PRINCETON AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELEVATION BASEMENT STAIRWELL MISSING GUARDRAIL. | 5914 S PRINCETON AVE | COMPLAINT | FAILED | View |