Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2014. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | EAST EXTERIOR STAIRWAY - GRADE TO 1ST - HANDRAILS - MISSING. SOUTHWEST EXTERIOR BASEMENT STAIRWAY - GRADE TO BASEMENT - CONCRETE STEPS - FRACTURED AND BROKEN WITH MISSING CONCRETE SECTIONS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | SOUTHWEST BASEMENT STAIRWAY - GRADE TO BASEMENT - GUARDRAILS AND HANDRAILS - MISSING. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | SOUTH 3 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED TO COLUMNS. LEDGER BEAMS ONLY NAILED TO BUILDING. DECK JOISTS ONLY NAILED TO HEADER JOISTS AND RIM JOISTS. COLUMN SPLICES ONLY 10'' LONG. STRINGERS ONLY NAILED TO HEADER JOISTS AND COLUMNS. LOOSE GUARDRAILS ONLY 34'' HIGH. PLANS AND PERMIT REQUIRED FOR SOUTH 3 STORY PORCH REPAIRS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR PLATFORM | REAR 1 STORY DECK - BEAMS ONLY NAILED OR SCREWED TO COLUMNS. GUARDRAILS ONLY 34'' HIGH. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
NO CLOSET/STORAGE UNDER STAIR | SOUTH 3 STORY PORCH - UNDERNEATH PORCH / STAIRS- STORING YARD EQUIPMENT , CONSTRUCTION ITEMS AND PERSONAL ITEMS . | 7522 N EASTLAKE TER | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | BASEMENT CEILING - OPEN HOLES - MISSING DRYWALL / PLASTER - EXPOSED WOOD SHEATHING , LATH , AND FLOOR JOISTS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPLACE DEFECTIVE VALVE,PIPING | BASEMENT - 2'' PLASTIC DRAIN LINE AT CEILING TO FLOOR DRAIN - RUBBER COUPLING - DEFECTIVE DRAIN PIPES. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | BASEMENT - EXCESSIVE STORAGE OF MECHANICAL EQUIPMENT , PERSONAL ITEMS , JUNK AND DEBRIS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - MOST APARTMENTS - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT ALL STAIRWAYS AND EGRESSES. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
EXPOSED WIRING | BASEMENT THROUGHOUT - LOOSE AND EXPOSED ELECTRICAL WIRING. ELECTRICAL PERMIT REQUIRED FOR ALL ELECTRICAL WIRING REPAIRS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
COVER OUTLETS AND JBS | BASEMENT THROUGHOUT - OPEN ELECTRICAL JUNCTION BOXES - WALLS AND CEILINGS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AT 3RD - SMOKE DETECTOR - MISSING. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY - 1ST THROUGH 3RD - HANDRAILS AND GUARDRAILS - MISSING. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR APARTMENTS - CARBON MONOXIDE DETECTORS - MISSING. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
PROVIDE | FRONT INTERIOR STAIRWAY - PER SECTION 33[13 - 124 - 350 ] - PROVIDE SAFETY GLASS FOR ENTRY DOORS WITH GLASS PANEL S- WITH GLASS ABOVE FLOOR 8'' TO 12'' . | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
STAIR: SELF-CLOSE 1-3/4" DOOR | FRONT INTERIOR STAIRWAY APARTMENT ENTRY DOORS - LESS THAN 1 3/4'' THICK - WOOD PANEL DOORS. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR FLOOR | 1ST FLOOR NORTH APARTMENT - KITCHEN , HALL , AND BATHROOM FLOORS - BUCKLED , BROKEN , SAGGING , AND WEAK . | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR DOOR, INT. | 1ST FLOOR NORTH APARTMENT - WOOD ENTRY DOOR -STILE IS BROKEN , LOOSE AND COMING APART. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
NO CLOSET/STORAGE UNDER STAIR | SOUTH 3 STORY PORCH - UNDERNEATH PORCH / STAIRS- STORING YARD EQUIPMENT , CONSTRUCTION ITEMS AND PERSONAL ITEMS . | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | EAST ENTRY DOOR - SIDE LITE - CRACKED GLASS PANE. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | 1ST FLOOR DRYER VENT - VENTING TO BASEMENT - HAZARDOUS - GAS FROM FLUE GOING INTO BASEMENT. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |
PARAPET | SOUTH , EAST , AND WEST PARAPET WALLS - WASHED OUT MORTAR. | 7522 N EASTLAKE TER | COMPLAINT | CLOSED | View |