Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH AND SOUTH ELEVATIONS/ CHIMNEYS - WASHED OUT MORTAR. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH ELEVATIONS/ PARAPET WALLS - SPALLING AND LOOSE BRICKS WITH WASHED OUT MORTAR.PERMIT REQUIRED FOR MASONRY REPAIRS. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1ST FLOOR STAIRWAY/ MASONRY WING WALLS - FRACTURED AND SHIFTED MASONRY AND LOOSE BRICKS WITH WASHED OUT MORTAR.PERMIT REQUIRED FOR MASONRY REPAIRS. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR ELEVATION/ 1ST FLOOR WINDOW - BOARDED UP. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AND 2ND FLOOR APT. - MISSING SMOKE DETECTORS. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 2-STORY PARTIALLY ENCLOSED WOOD PORCH/ COLUMNS - RESTING ON DIRT, FOUNDATION STATUS UNKNOWN. COLUMNS - ROTTED AND DOUBLE NOTCHED FOR RIM JOISTS; BUTTED JOINT IS ONLY NAILED TOGETHER. BEAMS - PULLING OUT OF FIRE CUTS AND ONLY NAILED TO COLUMNS. UNDERSIZED 2X8 DECK JOISTS ARE OVERSPANNED. RIMS AND HEADER JOISTS - ONLY NAILED TO COLUMNS. STRINGERS - UPPER ENDS ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. ENTIRE LANDING DECK SWAYS SIDE TO SIDE. RAILINGS - ONLY 34 INCHES HIGH, LOOSE, PULLING AND MISSING PICKETS.PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS/ VARIOUS WINDOWS - MISSING SCREENS. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
INSECTS | BUILDING INCLUDING 2ND FLOOR APARTMENT - BED BUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 1ST FLOOR AND BASEMENT - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT SOME INTERIOR STAIRWAYS. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELEVATION/ CHIMNEY - MISSING CAPPING. | 6240 S CHAMPLAIN AVE | COMPLAINT | FAILED | View |