Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AND NORTH ELEVATION - 1ST FLOOR WINDOW PANES , BROKEN. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR APARTMENT - FRONT BEDROOM AND BATHROOM CEILING TILE BUCKLING , WATER DAMAGED. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | 1ST FLOOR APARTMENT - BATHROOM , OUTLET COVER MISSING. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 1ST FLOOR APARTMENT - BATHROOM LIGHT FIXTURE , WATER DAMAGED. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR APARTMENT - SMOKE DETECTOR , OUT OF SERVICE , BATTERY MISSING. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR APARTMENT - CARBON MONOXIDE DETECTOR , OUT OF SERVICE , BATTERY MISSING. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION - HOLES IN SIDING. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH - 6X6 BOWED , FOUNDATION FOOTING STATUS UNKNOWN. RIM JOIST ROTTED TOE-NAIED TO COLUMNS. BEAM NOTCHED AT COLUMN CONNECTION , STEEL ANGLE BRACKETS MISSING.DECK BOARDS WORN AND WEAK . IRON RAILING SECTIONS LOOSE AND ONLY 30 " IN HEIGHT. PLANS AND PERMIT REQUIRED TO REPAIR PORCH.REAR PORCH - 6X6 COLUMNS BOWED , FOUNDATION STATUS UNKNOWN, COLUMN SPLICE ONLY 18 " IN DEPTH , WITH ONLY TWO BOLT . 2X8 RIM JOIST ROTTED AND OVER-SPANNED AT 10 ' . 2X6 DECK JOIST LAMINATED , MISSING HANGERS , CRACKED AND DAMAGED WOOD. 2ND FLOOR STRINGER MISSING BOLTS AT EXTERIOR WALL . TREADS AND RISERS CRACKED. RAILING SECTIONS LOOSE , MISSING PICKETS AND ONLY 28" IN HEIGHT.6X6 PULLING AWAY FROM COLUMN. 2X6 RIM JOIST UNDERSIZED COLUMN OVER SPANNED AT 10 ' ON 2ND FLOOR.DECK BOARDS WORN AND WEAK. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS - WINDOW SASHES ROTTED. | 9351 S LYON AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - SERVICE DOOR UNSECURED , OPEN | 9351 S LYON AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS - WINDOW FRAMES ROTTED. | 9351 S LYON AVE | COMPLAINT | FAILED | View |