Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | MANAGEMENT SIGN - MISSING | 2552 N HALSTED ST | PERIODIC | FAILED | View |
NO POSTED ADDRESS | ADDRESS - NOT POSTED | 2552 N HALSTED ST | PERIODIC | FAILED | View |
INSTALL EXIT SIGN | 1ST FLOOR STOREFRONT - EXIT SIGNS MISSING AT FRONT AND REAR EXITS | 2552 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR STAIRS (2ND FLOOR TO GRADE) - SPIRAL STAIRCASE IS MODE OF REAR EXIT FOR 3-STORY MIXED USE BUILDING; REAR STAIRS (2ND TO 3RD FLOOR) - FOUNDATION STATUS UNKNOWN; 2X6 LEDGERBOARD ROTTING; 2X6 STRINGERS; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS, TWISTING AND LEANING; SPINDLES MISSING AT HANDRAILS; HANDRAILS ROTTING, DEFLECTING - VERY LOOSE; WIDTH OF STAIRS ONLY 25"; TREADS SPLINTERING, ROTTING; RISERS CUPPING. PLANS AND PERMIT REQUIRED TO REPLACE REAR STAIRS. | 2552 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | WEST/2ND FLOOR - SKYLIGHT - CRACKED | 2552 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR PLATFORM | WEST/2ND FLOOR ROOF DECK - GUARDRAILS MISSING AROUND SKYLIGHT; FALL HAZARD | 2552 N HALSTED ST | PERIODIC | FAILED | View |
BUILDING IN DISREPAIR | WEST/2ND FLOOR ROOF DECK - GUARDRAILS MISSING AROUND SKYLIGHT; FALL HAZARD;SPIRAL STARCASE IS MODE OF EXIT FOR 3-STORY MIXED USE BUILDING;REAR EXIT FROM 2ND FLOOR APARTMENT IS THROUGH PATIO DOORS; | 2552 N HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WEST - WINDOW UNIT (3RD FLOOR) - GAPS AT WINDOW HEADERS; WINDOW TRIM - ROTTING, PAINT PEELING THRU-OUT | 2552 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST/EXTERIOR WALL - SPALLING BRICKS | 2552 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | WEST/2ND FLOOR - PATIO DOORS ARE THE ONLY FORM OF REAR EGRESS | 2552 N HALSTED ST | PERIODIC | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | WEST/2ND FLOOR - SPIRAL STAIRCASE USED AS MODE OF EGRESS FOR 2ND, 3RD FLOOR APARTMENTS; 2ND FLOOR APARTMENT REAR EGRESS IS THROUGH PATIO DOORS. | 2552 N HALSTED ST | PERIODIC | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | WEST - REAR EGRESS FOR 2ND, 3RD FLOOR APARTMENTS IS THROUGH RESTUARANT TERRACE. | 2552 N HALSTED ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | WEST/2ND FLOOR ROOF DECK - WIRES, CORDS, LIGHT FIXTURES FROM RESTAURANT NEAR SPIRAL STAIRCASE; OBSTRUCTION AND TRIP HAZARD | 2552 N HALSTED ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIRWELL/3RD FLOOR - SMOKE DETECTOR - MISSING | 2552 N HALSTED ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWELL - VERY LOOSE, WEAK TREADS AND FLOORBOARDS FROM 1ST TO 3RD FLOOR; VERY LOOSE DECK AT 2ND FLOOR | 2552 N HALSTED ST | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | WEST - SUBMIT PLANS AND PERMIT FOR ALL WORK RELATED TO: 1) PROVIDE SUFFICIENT REAR EGRESS FOR 2ND, 3RD FLOOR APARTMENTS, AND 2) CONSTRUCTION OF SKYLIGHT AT 2ND FLOOR ROOF DECK REPLETE WITH FALL PROTECTION OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 2552 N HALSTED ST | PERIODIC | FAILED | View |
DOOR PROJECT INTO PUBLIC WAY | WEST/3RD FLOOR - SCREEN DOOR SWINGS OUT ONTO REAR STAIRS | 2552 N HALSTED ST | PERIODIC | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | THERE IS A REAR EXIT SIGN MISSING AT THE PATIO AREA. ALSO, THERE ARE NO DIRECTIONAL SIGNS AT THE REAR ROOF TOP AREA. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.13. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELEVATION METAL FENCE IS LEANING TOWARD THE PUBLIC WAY. THE WEST ELEVATION WOOD FENCE IS LEANING TOWARD THE PUBLIC ALLEY. UNSAFE CONDITION.SECTION 14X-3-302.3. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | THE REAR STAIRS BETWEEN 2554 AND 2558 HAVE UNEVEN RISER HEIGHTS. THE STAIR STRUCTURE ITSELF IS UNSTABLE AND FLEXES UNDER LOAD. DANGEROUS AND HAZARDOUS.ALSO, THERE ARE NO STAIRS AT THE NORTH (REAR) EXIT FROM 2558. THE STEP DOWN FROM THE DOOR THRESHOLD IS 11 1/2 INCHES. DANGEROUS AND HAZARDOUS. SECTION 14X-3-303.1.1. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | IN EACH OF THE 3 BASEMENT SECTION THERE ARE OPEN (WOOD) FLOOR JOISTS AT THE CEILING WITHOUT THE PROTECTION OF (1 HOUR) OF FIRE RESISTIVE MATERIAL. DANGEROUS AND HAZARDOUS.SECTION 14B-5-509 AND TABLE 509. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | THE 3 REAR EXITS FROM THE MAIN NIGHT CLUB ARE THROUGH A REAR PATIO DINING AREA WITH FIXED SEATING / TABLES, 2 LARGE TENTS AND A MASSIVE PERGOLA SYSTEM SEVERELY OBSTRUCTING EGRESS. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
FOUNDATION FOR FURNACE/BOILER | AT THE REAR ROOF AREA THERE IS A STRUCTURALLY SUBSTANDARD BRACING SYSTEM SUPPORTING A HEAVY AC UNIT THAT IS PARTIALLY SET ON BRITTLE CLAY ROOF TILES. DANGEROUS AND HAZARDOUS.SECTION 14X-8-804.1. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | THERE IS A STAND ALONE GAS FIRED FURNACE IN THE BASEMENT WITH NO FIRE RESISTIVE ENCLOSURE. DANGEROUS AND HAZARDOUS.SECTION 14B-5-509 AND TABLE 509. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | AT THE REAR DINING PATIO AREA THE CONCRETE FLOOR SEGMENTS HAVE BECOME FROST HEAVED AND ARE AT VARYING HEIGHTS. THIS CONDITION PRESENTS A SEVERE TRIP HAZARD AT MULTIPLE LOCATIONS. DANGEROUS AND HAZARDOUS.SECTION 14X-3-303.12. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WORK PERFORMED WITHOUT PLANS / PERMIT OR ZONING AUTHORIZATION AND RESTORE TO ORIGINAL CONDITION. REMOVE THE APARTMENT AND APARTMENT DUPLEX (2558 AND 2554 RESPECTIVELY). RE-INSTALL EXTERIOR WALL THAT HAVE BEEN REMOVED AT 2552, 2554 AND 2558. IF PERMITS ARE NOT OBTAINED, REMOVE ALL PLUMBING / ELECTRICAL PIPING AND FIXTURES.SECTION 14A-4-401. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | THE REAR ROOF TOP AREA HAS NO DEDICATED EXIT ILLUMINATION. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.6.1. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THIS INSPECTION CONCERNS A RESTAURANT / NIGHT CLUB / BAR KNOWN AS LAS FUENTES. THIS CLUB / BAR / RESTAURANT IS ACTUALLY COMPRISED OF THE 1ST FLOOR AREAS OF 3 SEPARATE, DISTINCT BUILDINGS (WITH 3 SEPARATE ADDRESSES) THAT HAVE BEEN COMBINED, AT THEIR 1ST FLOORS, INTO 1 SINGLE VENUE. TO ACCOMPLISH THIS, THE NORTH EXTERIOR WALL AT THE 1ST FLOOR OF 2552 HAD TO BE REMOVED AS WELL AS THE SOUTH EXTERIOR WALL AT THE 1ST FLOOR OF 2554. IN ADDITION TO THESE TWO COMPLETE (1ST FLOOR) REMOVAL OF EXTERIOR WALLS, THE NORTH EXTERIOR WALL OF 2554 WAS ALSO REMOVED TO JOIN / BREACH INTO THE 2558 FIRST FLOOR SPACE. THE SOUTH EXTERIOR WALL OF 2558 REMAINS, BUT HAS BEEN BREACHED BY A DOUBLE GLASS DOOR WALL OPENING. NONE OF THIS WORK WAS APPROVED BY EITHER THE DEPARTMENT OF ZONING OR THE DEPARTMENT OF BUILDINGS. THERE ARE NO PLANS OR PERMITS ON FILE FOR ANY OF THIS WORK. THERE IS NO APPLICATION TO THE DEPARTMENT OF ZONING TO REQUEST THE JOINING OF 3 BUILDINGS AT THE 1ST FLOOR TO CREATE 1 RESTAURANT / BAR / NIGHT CLUB. ALSO, THERE HAS BEEN EXTENSIVE ELECTRICAL AND PLUMBING WORK DONE WITHOUT PLANS OR PERMITS AT BOTH THIS VENUE AND THE LARGE (REAR) PATIO AREA. THE REAR PATIO AREA HAS A LARGE ARRY OF PERGOLAS CONSTRUCTED (45 LINEAR FEET X 15 FEET IN HEIGHT X 10 FEET IN WIDTH). ALSO, THERE ARE NO PLANS OR PERMITS ON FILE FRO A NEW REAR EXTERIOR PORCH FRON THE REAR ROOF AREA OF 2552 TO THE 3RD FLOOR OF 2552.ALSO. THERE ARE NO PLANS OR PERMITS ON FILE FOR THE REAR ROOF TOP DECK AT 2552.ALSO, THERE HAS BEEN EXTENSIVE INTERIOR WORK PERFORMED TO THE DWELLING UNITS AT 2552 AND 2554.ALSO, THERE ARE NO PLANS / PERMITS OR LICENSES FOR THE REAR PATIO AREA AND THE 2 LARGE REAR PATIO AREA TENTS.ALSO, THE 2CD FLOOR OF 2558 HAS BEEN DUPLEXED INTO THE ATTIC WITHOUT PLANS OR PERMITS.ALSO, THE ATTIC AT 2554 HAS BEEN CONVERTED INTO AN APARTMENT.THIS VENUE HAS BEEN ISSUED A CLOSURE ORDER BY THE DOB.SECTION 14X-4-401.1. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | THE INTERIOR STAIRS AT 2554 HAS A MISSING GAURDRAIL. DANGEROUS AND HAZARDOUS.SECTION 14X-3-304.4. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THERE ARE 3 FRONT AND 3 REAR EXIT DOORS AT THIS RESTARAUNT / BAR / NIGHT CLUB. THE VIOLATIONS REGARDING EGRESS OBSTRUCTION FALL INTO 2 CATEGORIES AT THIS VENUE. THE FIRST PROBLEM IS THERE ARE NO CRASH BARS AT ANY OF THESE DOORS AT THIS HIGH OCCUPANT CAPACITY VENUE. EACH DOOR HAS A THUMB LATCH. THE SECOND AND EXTREMELY DANGEROUS AND HAZARDOUS OBSTRUCTION IS THE POLICY / PROCEDURE AT THIS VENUE. MANAGEMENT, AS A MATTER OF POLICY, INSTRUCTS ALL SECURITY PERSONEL TO KEEP ALL EXIT DOORS LOCKED WHILE THE VENUE IS OPEN FOR BUSINESS. THIS INSANELY DANGEROUS POLICY WAS WITNESSED BY THIS INSPECTOR. UPON ARRIVAL, THIS TASK FORCE ENTERED THE VENUE AFTER THE SECURITY GAURD UNLOCKED 1 OF 3 FRONT DOORS. THE OTHER 5 EXIT DOORS WERE LOCKED AND THE DOOR WE ENTERED WAS RE-LOCKED AFTER WE ENTERED. SECURITY WAS INSTRUCTED BY THIS INSPECTOR TO IMMEDIATELY UNLOCK ALL EXIT DOORS. THEY REFUSED. THIS INSPECTOR THEN PERSONALLY OPENED / UNLATCHED ALL 6 EXIT DOORS. THIS INSPECTOR THEN DID A 10 MINUTE INSPECTION OF THE BASEMENT AND FOUND THE SECURITY STAFF HAD RE-LOCKED ALL 6 EXIT DOORS. AGAIN, THIS INSPECTOR, FOR THE 2CD TIME, UNLOCKED ALL EXIT DOORS. THEN, FOR THE 3RD TIME, MANAGEMENT INSTRUCTED SECURITY TO RE-LOCK ALL EXIT DOORS. AT THIS POINT, THE VENUE WAS CLOSED BY ADMINISTRATIVE ORDER.ALSO, AT THE REAR PATIO AREA, ONE OF THE EXIT GATES WAS PADLOCKED.SECTION 14X-5-505.1.2. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | THIS REPORT IS TO EXIMINE THE WORK PERFORMED AT LAS FUENTES RESTRAUNT / BAR / NIGHT CLUB AT 2552-2558 N. HALSTED. SPECIFICALLY, THE FIRST FLOOR(S) OF EACH OF 3 BUILDINGS (2552, 2554 AND 2558) HAVE BEEN COMBINED INTO A SINGLE VENUE. THE1ST FLOOR (NORTH) WALL HAS BEEN COMPLETELY REMOVED FROM 2552. BOTH THE SOUTH AND NORTH (1ST FLOOR) WALLS OF 2554 HAVE BEEN REMOVED. THE SOUTH WALL OF 2558 HAS BEEN BREACHED INTO THE OPEN SPACE OF 2552 / 2554. THERE IS NO VISABLE REPLACEMENT STRUCTURAL MEMBERS TO SUPPORT THESE BUILDING AFTER THE REMOVAL OF THESE VITAL LOAD BEARING WALLS. A CRITICAL EXAMINATION IS REQUIRED THAT MAY WELL REQUIRE THE REMOVAL OF INTERIOR WALL COVERINGS DURING THIS EXAMINATION.SECTION 14X-3-303.1.1. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | THERE WERE NO SMOKE DETECTORS IN THE BASEMENT STAIRWELLS. DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.8. | 2552 N HALSTED ST | COMPLAINT | FAILED | View |