| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| REPAIR FLOOR | 414 MISSING FLOOR TILES VARIOUS AREAS THROUGHOUT STORE, UNEVEN CONCRETE CAUSING A TRIP HAZARD. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| REMOVE | 414 AISLE RESTRICTION, VARIOUS LOCATIONS THROUGHOUT STORE, DOWN TO 25 INCHES DUE TO PLACEMENT OF SHELVING AND OVER STOCK. (15-4-880) DANGEROUS AND HAZARDOUS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PLANS & PERMITS REQ - CONTRCTR | 414 - 19 3/4 INCH HIGH PLATFORM INSTALLED BEHIND COUNTER, APPEARS TO BE CONSTRUCTED OUT OF WOOD PALLETS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| REPAIR INTERIOR STAIR SYSTEM | 414 STEPS LEADING TO 19 3/4 INCH PLATFORM CONSIST OF 1 PARTICLE BOX 12 1/2 INCHES HIGH, 2ND STEP 7 1/4 INCHES HIGH. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| REPAIR ROOF STRUCTURE | 414 NORTH EAST ELEVATION ABOVE DROPPED CEILING, ORIGINAL CEILING CONSTRUCTED OUT OF 2X6 JOIST, 2 SECTIONS OF 2X6'S REMOVED AND NOT FASTENED CAUSING DANGEROUS AND HAZARDOUS CONDITIONS (POSSIBLE COLLAPSE OF CEILING ONTO PUBLIC). | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| REMOVE | 414 - ALL CEILING TILES TO BE REMOVED FOR COMPLETE CEILING INSPECTION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROPER MATRL WATER SUPPLY PIPE | 414 - REMOVE FLEXIBLE SUPPLIES TO LAVATORY AND TOILET EAST ELEVATION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| REPLACE DEFECTIVE TRAP | 414 - REMOVE PVC P-TRAP LAVATORY EAST ELEVATION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROVIDE | 414 - PROVIDE SAFE PAN UNDER WATER HEATER EAST ELEVATION. (18-29-504.8) | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROVIDE | 414 - PROVIDE FLOOR DRAIN FOR WATER HEATER EAST ELEVATION. (18-29-412.4) | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROVIDE OPEN FRONT TOILET SEAT | 414 - PROVIDE OPEN FRONT TOILET SEAT. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROVIDE | 414 - PROVIDE LAUNDRY TUB OR MOP SINK. (18-29-403.1) | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROVIDE | 414 - PROVIDE DRINKING FOUNTAIN. (18-29-504.2) | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| DEFECTIVE LIGHTING SERVICE | 414 - REPLACE DEFECTIVE SERVICE RISER AND CABLES. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| DEFECTIVE METER EQUIPMENT | 414 - REPLACE RUSTED METER BOX AT REAR EXTERIOR AREA OF BUILDING. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| CONTINUITY OF RACEWAY | 414 - PROVIDE GROUND CONTINUITY FOR BARE WIRES THROUGHOUT CEILING AREAS AND LIGHT FIXTURES WITH BARE WIRE THROUGHOUT ALL STORE AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| WORKING SPACE | 414 - PROVIDE PROPER CLEARANCES FOR ELECTRICAL PANEL BURIED BEHIND WALL NEAR REAR DOOR AREA. DANGEROUS AND HAZARDOUS CONDITION DUE TO NOT READILY ACCESSIBLE FOR EMERGENCY CONDITIONS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| ADD RECEPTACLES | 414 - ADD RECEPTACLES TO EASE EXTENSION CORDS THROUGHOUT ALL STORE AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| INSTALL COVERS | 414 - PROVIDE PROPER TYPE COVER FOR OPEN JUNCTION BOXES WITH EXPOSED WIRING ABOVE LAYIN AND DRYWALL CEILING AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| ARMORED CABLE | 414 - REMOVE ALL DEFECTIVE AND EXCESSIVE USE OF ARMORED CABLE ABOVE LAYIN AND DRYWALL CEILING AREAS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| SECURE RACEWAY | 414 - PROPERLY SUPPORT ALL CONDUIT, JUNCTION BOXES ABOVE LAYIN AND DRYWALL CEILING AREAS - DANGEROUS AND HAZARDOUS CONDITION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| SECURE RACEWAY | 414 - AT REAR EXTERIOR AREA OF BUILDING HAS 1/2" CONDUIT JUNCTION BOXES AND LIGHT FIXTURE NOT SECURED, READY TO FALL - DANGEROUS AND HAZARDOUS CONDITION. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| CORRODED CONDUIT & EQUIP | 414 - REMOVE AND REPLACE ALL RUSTED, CORRODED CONDUIT, BOXES AND ELECTRICAL EQUIPMENT AT REAR EXTERIOR AREAS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| 414 - CEILING GRIDS AND SUPPORT WIRES SHALL NOT BE USED FOR SUPPORT. PROPERLY SUPPORT ALL LIGHT FIXTURES FROM THE GRID. (18-27-300.11) | 414 E 71ST ST | COMPLAINT | CLOSED | View | |
| OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. (13-12-360) | 414 E 71ST ST | COMPLAINT | CLOSED | View | |
| 414 - REMOVE ALL ABANDONED RACEWAY, BOXES, CABLE AND ELECTRICAL EQUIPMENT ABOVE LAYIN AND DRYWALL CEILING AREAS. (18-27-110.12(E) | 414 E 71ST ST | COMPLAINT | CLOSED | View | |
| SEE INSPECTOR COMMENTS | 414 - PROVIDE GFCI PROTECTION FOR BATHROOM AREA. (18-27-210.8) | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| OBSTRUCTIONS IN EXIT WAY | 414 DOOR AT PLATFORM SWINGS INCORRECT DIRECTION CAUSING EGRESS FROM BEHIND COUNTERTOP. REAR EXIT DOOR OBSTRUCTED BY: (1). PARTITION INSTALLED IN FRONT OF DOOR BEING USED TO HANG CLOTHING FROM FOR DISPLAY. (2). PARTITION DOOR OBSTRUCTED BY PLATFORM AND STAIRS TO PLATFORM NOT ALLOWING DOOR TO OPEN COMPLETELY. EGRESS DOWN TO 28 INCHES CAUSING DANGEROUS AND HAZARDOUS CONDITIONS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| PROVIDE | 414 - PROVIDE PROPER CLEARANCE BETWEEN PLUMBING FIXTURES AND IN FRONT OF FIXTURES. (18-29-405.3.1) | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| REPAIR/REPLACE SMOKE DETECTORS | 414 - BEEPING SMOKE DETECTOR - DANGEROUS AND HAZARDOUS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| III-B AND IV-A FIRE RESISTANCE | 414 FURNACE ROOM: OPEN STUDS, MISSING DOOR, BLOCKED BY OVERSTOCK - DANGEROUS AND HAZARDOUS. | 414 E 71ST ST | COMPLAINT | CLOSED | View |
| DEFECTIVE FIXTURES | 414 - REPLACE DEFECTIVE LIGHT IN BATHROOM. | 414 E 71ST ST | COMPLAINT | CLOSED | View |