PIN: 25014220010000
Property Address: 2235 E 93RD ST
City - Zip: CHICAGO - 60617
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70130
2023 Tax District: 70002
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 29 Violations
Violation Inspector Comments Address Category Status View
OBTN PERMIT FOR PLUMBING WORK 2235 E 93RD ST COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION FRONT BUILDING - EAST FOUNDATION STONE WALL - WASHED OUT MORTAR. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT BUILDING - FRONT STAIRWAY - GRADE TO 1ST - METAL STAIR RAILS - LOOSE. METAL GUARDRAILS LOOSE WITH MISSING PICKETS - PICKETS SPACED 5'' APART AND ONLY 31'' HIGH. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR ROOF FRONT BUILDING - WEST MANSARD ROOF - ROOFING SHINGLES - LOOSE AND MISSING. 2235 E 93RD ST COMPLAINT PASSED View
REPLACE D&H PORCH FRONT BUILDING - 3 STORY OPEN WOOD PORCH - GRADE TO ATTIC - PORCH IS WEAK AND UNSTABLE - COLUMNS ERECTED ON CONCRETE BASES - FOUNDATION STATUS UNKNOWN. UNDERSIZED 6 X 6 BEAMS SPAN 7' 7'' AND CONNECTED TO COLUMNS WITH NAILS OR SCREWS. UNDERSIZED 2 X 6 DECK JOISTS SPAN 7' 7'' WITH JOIST HANGERS SCREWED TO LEDGER BEAM AND SAGGING RIM JOISTS. MANY JOIST HANGERS WITH OPEN HOLES - MISSING NAILS. 4 X 4 COLUMN IS 32' TO 38' LONG WITH COLUMN LAP SPLICES ONLY NAILED OR SCREWED TOGETHER - WEAK . BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED OR SCREWED TO HEADER JOISTS AND COLUMNS. 2ND TO ATTIC GUARDRAIL AT LANDING IS BROKEN LOOSE FROM COLUMN - DANGEROUS AND HAZARDOUS. GUARDRAILS ARE LOOSE AND WEAK WITH LOOSE , BROKEN , AND MISSING PICKETS - DANGEROUS. HANDRAILS ARE LOOSE WITH BROKEN , LOOSE , AND MISSING PICKETS. DECKING IS ROTTED , BUCKLED , LOOSE , WEAK AND SAGGING. TREADS ARE SPLIT , LOOSE AND ROTTED. PLANS AND PERMIT REQUIRED FOR FRONT BUILDING , REAR PORCH REPLACEMENT. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR BUILDING - NORTH - 1STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE BASES - FOUNDATION STATUS UNKNOWN. UNDERSIZED 2 X 8 DECK JOISTS SPAN 10' 3'' . RIM JOISTS ONLY NAILED TO COLUMNS. 6 X 6 BEAMS CONNECTED TO BEAMS WITH 3/16'' THICK X 1 3/4'' X 5'' THIN METAL PLATE WITH NAILS - WEAK. STRINGERS ONLY NAILED TO HEADER JOISTS AND COLUMNS. LOOSE GUARDRAILS - ONLY 36'' HIGH. HANDRAILS WEAK AND VERY LOOSE. DECKING IS BUCKLED AND LOOSE. PLANS AND PERMIT REQUIRED FOR REAR BUILDING - NORTH PORCH REPAIRS. 2235 E 93RD ST COMPLAINT PASSED View
MAINTAIN WINDOW FRONT BUILDING - WEST , EAST , AND NORTH WINDOW FRAMES -1ST THROUGH ATTIC - PEELING PAINT. REAR BUILDING - 1ST AND 2ND - SOUTH WINDOW FRAMES - ROTTED WITH PEELING PAINT. 2235 E 93RD ST COMPLAINT PASSED View
WINDOW REPAIR FOR AIR SEEPAGE FRONT BUILDING - ALL ELEVATIONS - WINDOWS - DRAFTY AND LEAKING AIR. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR FLOOR FRONT BUILDING - 1ST FLOOR APARTMENT - LIVINGROOM WOOD FLOOR - BUCKLED AND UNEVEN. 2235 E 93RD ST COMPLAINT PASSED View
DWELLING CLEAN AND SANITARY FRONT BUILDING - 1ST FLOOR APARTMENT - LIVINGROOM AND DININGROOM WALLS - MILDEWED THROUGHOUT - VERY UNSANITARY CONDITIONS. BATHROOM - VANITY SINK BASE - BOTTOM DETERIORATED / ROTTED WITH MISSING SECTIONS - DAMP , MILDEWED , AND UNSANITARY CONDITIONS. 2235 E 93RD ST COMPLAINT PASSED View
INT WALL/CEILING PEELING PAINT FRONT BUILDING - 1ST FLOOR APARTMENT - LIVINGROOM AND DININGROOM WALLS - WATER STAINED - LOOSE PAINT THROUGHOUT. 2235 E 93RD ST COMPLAINT PASSED View
REPLACE DEFECTIVE FAUCET FRONT BUILDING - 1ST FLOOR APARTMENT - BATH TUB FAUCET HANDLE - MISSING. 2235 E 93RD ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID FRONT BUILDING - 1ST FLOOR APARTMENT - CARBON MONOXIDE DETECTOR - MISSING. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR EXTERIOR DOOR SILL FRONT BUILDING - NORTH AT 1ST - ENTRY DOOR SILL - GAPPED AT DOOR - LEAKING COLD AIR INTO BUILDING. 2235 E 93RD ST COMPLAINT PASSED View
COVER OUTLETS AND JBS FRONT BUILDING - SOUTH AT 1ST UNDER PORCH - OPEN ELECTRICAL JUNCTION BOX. REAR BUILDING - SOUTH WALL AT 1ST - OPEN ELECTRICAL SERVICE JUNCTION BOX - ELECTROCUTION HAZARD AT ALLEY . 2235 E 93RD ST COMPLAINT PASSED View
EXPOSED WIRING FRONT BUILDING - SOUTH AT 1ST - UNDER PORCH - LOOSE ELECTRICAL WIRES WITH ELECTRICAL OUTLET - HAZARDOUS. 2235 E 93RD ST COMPLAINT PASSED View
PROVIDE GUTTER & DOWNSPOUT FRONT BUILDING - REAR PORCH ROOF - GUTTERS AND DOWNSPOUTS - MISSING. REAR BUILDING - NORTH PORCH ROOF - GUTTERS AND DOWNSPOUTS - MISSING. 2235 E 93RD ST COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS FRONT BUILDING - WEST AT 1ST WINDOW - BROKEN PANE . REAR BUILDING - WEST AT 1ST AND SOUTH AT 2ND - WINDOWS - BROKEN PANES. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR EXTERIOR WALL FRONT BUILDING AT 1ST - SOUTHEAST - LOOSE AND MISSING SIDING SECTIONS. REAR BUILDING AT 2ND SIDING SECTION - MISSING. 2235 E 93RD ST COMPLAINT PASSED View
DEFECTIVE FIXTURES WATER IN FIXTURE 3RD KITCHEN AND BEDROOM, 2ND BATH D&H 2235 E 93RD ST COMPLAINT PASSED View
DEFECTIVE OUTLETS THROUGHOUT 2235 E 93RD ST COMPLAINT PASSED View
CONTINUITY OF RACEWAYS REAR PORCH D&H 2235 E 93RD ST COMPLAINT PASSED View
REMV OBSTR FROM DRAINAGE SYSTM THIRD FLOOR ROD ALL STOPPED FIXTURES THIRD FLOOR 2235 E 93RD ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE LAVATORY WATER CLOSET KITCHEN PROVIDE CODE APPROVED WATER SUPPLIES ONLY 2235 E 93RD ST COMPLAINT FAILED View
REPLACE DEFECTIVE FLUSH DEVICE SAME UNIT (18-29-102.3) 2235 E 93RD ST COMPLAINT FAILED View
STOP LEAKING WATER SECOND FLOOR BATHROOM DINING ROOM REPAIR ALL LEAKS THROUGH OUT APARTMENT 2235 E 93RD ST COMPLAINT FAILED View
REPAIR EAVES FRONT BUILDING - WEST EAVES - SECTION MISSING - OPEN HOLE. 2235 E 93RD ST COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM FRONT BUILDING - FRONT INTERIOR STAIRWAY - 1ST TO 2ND - WINDER TREADS WEAK AND BROKEN. 2235 E 93RD ST COMPLAINT PASSED View
TENANT ACCESS TO SERVICE BASEMENT 2235 E 93RD ST COMPLAINT PASSED View