The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
| Violation | Inspector Comments | Address | Category | Status | View |
|---|---|---|---|---|---|
| ARRANGE PREMISE INSPECTION | 07-02452164/NO ENTRY TO INTERIOR TO VERIFY DETECTORS OR BASEMENT | 1628 W BALMORAL AVE | COMPLAINT | FAILED | View |
| REPAIR PORCH SYSTEM | NORTH WEST ELEVATION PORCH SYSTEM NEWLY BUILT MISSING BOLTS ON BEAM TO COLUMN CONNECTIONS NO BOLTS STRINGERS TO SUPPORT POSTS OR TO BUILDING,IMPROPER FOOTING GARD RAILS TO LOW AT 36" MUST BE AT 42" SOUTH WEST PORCH SYSTEM ORIGINAL GARD RAILS VERY WEAK DEFLECT UNDER LOAD,ALSO AT 36" MUST BE AT 42" STRINGERS NOT BOLTED TO BUILDING OR TO SUPPORT, JOIST OVER SPAND. ROTTING DECKING ORIGINAL PLANS AND PERMITS REQUIRED FOR REPAIRS | 1628 W BALMORAL AVE | COMPLAINT | FAILED | View |
| NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCKS ON FRONT AND REAR GATES | 1628 W BALMORAL AVE | COMPLAINT | FAILED | View |
| PARAPET | ERODED PARAPET WALL ON NORTH ELEVATION | 1628 W BALMORAL AVE | COMPLAINT | FAILED | View |
| REPAIR EXTERIOR WALL | SPALLING BRICK AND ERODED MORTOR JOINTS ON 3RD FLOOR NORTH ELEVATION WINDOW FILLIN | 1628 W BALMORAL AVE | COMPLAINT | FAILED | View |
| 1HR FLR OVER BSMT, 1 OR 2 DU | 1628 & 30 BASEMENTS:HOLES IN CEILINGS | 1628 W BALMORAL AVE | COMPLAINT | CLOSED | View |
| OBSTRUCTIONS IN EXIT WAY | SERVICE GATES:DOUBLE CYLINDER LOCKS | 1628 W BALMORAL AVE | COMPLAINT | CLOSED | View |
| REPAIR LINTELS | RUSTED LINTELS ABOVE ENTRY DOORS | 1628 W BALMORAL AVE | COMPLAINT | CLOSED | View |
| REPAIR PORCH SYSTEM | REAR PORCHES: SOUTH PORCH:NO JOIST HANGERS, STRINGERS NOT BOLTED TO WALLS ON POSTS; 4X4 POSTS SET ON CONCRETE WALKS, SOME WEAK TREADS; RAILS NOT 42 INCHES AND DEFLECT ON LOAD, NOT ANCHORED PROPERLY SOME ROTTED DECKING NORTH PORCH'S STRINGERS NOT BOLTED TO WALL OR POSTS; JOIST NO HANGERS-PLANS AND PERMIT REQUIRED FOR REPAIR | 1628 W BALMORAL AVE | COMPLAINT | CLOSED | View |