Chicago Building Violations Data: 35 Violations
Violation Inspector Comments Address Category Status View
OBTAIN REFRIGERATION PERMIT FOR THE NEW UNIT LOCATED ON THE ROOF WITH TWO COMPRESSORS IN THE UNIT 400 E 103RD ST PERIODIC FAILED View
ADD RECEPTACLES ADD RECEPTACLES AT FRONT CEILING AREA COUNTER AREA AND WHERE REQUIRED THROUGHOUT PREMISES TO ELIMINATE UNAPPROVED EXCESSIVE EXTENSION CORD USAGE DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
PROVIDE HOT WATER TANK BLOCKED WITH STOCK (18-29-504.6) 400 E 103RD ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM WOOD PLATFORM STAIRS MISSING GUARD/HANDRAIL (14X-3-304.4 THRU 14X-12-1202.5.5) 400 E 103RD ST COMPLAINT FAILED View
RESTORE EXIT AND EM EXIT SIGNS NOT WORKING 400 E 103RD ST COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHERS NOT PROPERLY TAGGED (14X-5-504.5) 400 E 103RD ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMITS REQUIRED FOR INTERIOR COMMERCIAL SPACE BUILDOUT, CURRENTLY PARTITION WALLS CONSTRUCTED VARIOUS LOCATIONS THROUGHOUT, REAR SOUTH EAST SECTION UPPER LEVEL STORAGE SPACE CONSTRUCTED, NORTHWEST SECTION 2FT HEIGHT BY APPROXIMATELY 300 SQ FOOT RAISED PLATFORM FOR COUNTER AREA NO PLANS OR PERMITS EXISTS FOR SUCH BUILDOUT 400 E 103RD ST COMPLAINT PASSED View
REMOVE REMOVE ALL OXYGEN TANKS FROM INTERIOR OF PROPERTY, CURRENTLY OXYGEN TANKS STORED WITHIN INTERIOR OF PROPERTY (DANGEROUS AND HAZARDOUS) (15-4-090) 400 E 103RD ST COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIR SYSTEM LEADING TO UPPER LEVEL STORAGE AREA SOUTH EAST LOCATION MISSING HAND RAIL 400 E 103RD ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR, (DANGEROUS AND HAZARDOUS) 400 E 103RD ST COMPLAINT PASSED View
FIRE EXTNGSHR RECHARGE & TAG EXPIRED FIRE EXTINGUISHER, RECHARGE AND RETAG ALL FIRE EXTINGUISHERS THROUGHOUT 400 E 103RD ST COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE UNAPPROVED FLEXIBLE WATER SUPPLY PIPING TO TOILET, AND LAVATORY AT EMPLOYEE BATHROOM (18-29-605) 400 E 103RD ST COMPLAINT PASSED View
INDIRECT CONN.FOR WATER SUPPLY TOILET WATER SUPPLY PIPING AT EMPLOYEE BATHROOM CROSS CONNECTED WITH SHOWER WAND AT ANGLE STOP EXPOSING PREMISES TO DANGEROUS AND HAZARDOUS CROSS CONNECTION (18-29-602) (18-29-608) 400 E 103RD ST COMPLAINT PASSED View
PRV FLUE FOR HOT WATER HEATER WATER HEATER FLUE PIPING TERMINATES INSIDE BUILDING NOT TO OUTER AIR THROUGH ROOF EXPOSING PREMISES TO DANGEROUS AND HAZARDOUS CARBON MONOXIDE GASES (13-152-400) 400 E 103RD ST COMPLAINT PASSED View
INSTALL SUFFICIENT FIXTURES NO DRINKING FOUNTAIN, NO SERVICE SINK (18-29-403) 400 E 103RD ST COMPLAINT PASSED View
SUBMIT PLANS FOR PLUMBING PRMT SUBMIT PLANS TO BUILDING, WATER AND SEWER DEPARTMENT FOR APPROVAL AND PERMIT BEFORE CONSTRUCTING ALTERING OR USING PLUMBING SYSTEM, SPECIFICALLY ENTIRE PLUMBING SYSTEM WAS MODIFIED WITHOUT PLANS OR PERMITS 400 E 103RD ST COMPLAINT PASSED View
OBTAIN PERMIT FOR PLUMBING OBTAIN PERMIT BEFORE CONSTRUCTING ALTERING OR USING PLUMBING SYSTEM 400 E 103RD ST COMPLAINT PASSED View
ENGAG LIC & BOND PLMBNG CNTRC ENGAGE LICENSED PLUMBING CONTRACTOR TO INSTALL PLUMBING 400 E 103RD ST COMPLAINT PASSED View
SEE INSPECTOR COMMENTS FLEXIBLE METAL CONDUIT (GREENFIELD) USED AT EXTERIOR NOT APPROVED FOR WET LOCATION (14E-3-348.12, 14E-3-348-30) 400 E 103RD ST COMPLAINT PASSED View
CORD TO FIXTURE UNAPPROVED CORD CONNECTED LIGHT FIXTURES AT FRONT EXTERIOR REMOVE UNAPPROVED CORD CONNECTED LIGHT FIXTURES WHERE REQUIRED 400 E 103RD ST COMPLAINT PASSED View
RESTORE EXIT AND EM UNAPPROVED INOPERABLE BATTERY LIGHTS AND EXIT SIGNS THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
INSTALL COVERS OPEN ELECTRICAL BOX WITH HANGING WIRES AT TOP REAR PLATFORM STAIRS CLOSE OPEN WHERE REQUIRED THROUGHOUT DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
DEFECTIVE OUTLETS EXCESSIVELY PAINTED GFCI RECEPTACLE AT BATHROOM REPLACE PAINTED DAMAGED DEVICES WHERE REQUIRED THROUGHOUT 400 E 103RD ST COMPLAINT PASSED View
SUPPORT OUTLET AND BOX UNSUPPORTED BOX AT TOP REAR PLATFORM STAIRS AND VARIOUS AREAS SUPPORT BOXES WHERE REQUIRED THROUGHOUT PREMISES 400 E 103RD ST COMPLAINT PASSED View
EXCESSIVE, UNSUPPORTED,UNAPPROVED FLEXIBLE METAL CONDUIT (GREENFIELD) AT TOP REAR PLATFORM STAIRS AND FRONT DOOR AREA INSTALL FLEXIBLE METAL CONDUIT IN APPROVED MANNER WHERE REQUIRED THROUGHOUT PREMISES (14E-3-348.12, 14E-3-348.30) 400 E 103RD ST COMPLAINT PASSED View
SECURE RACEWAY CONDUIT AT REAR CEILING AREA NOT SUPPORTED IN APPROVED MANNER SECURE RACEWAY IN APPROVED MANNER WHERE REQUIRED 400 E 103RD ST COMPLAINT PASSED View
CONTINUITY OF RACEWAYS RACEWAY NOT SECURED TO BOX AT FRONT EXTERIOR AT MAIN DOOR ENSURE GROUND CONTINUITY WHERE REQUIRED DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
EXPOSED WIRING EXPOSED WIRING AT FRONT SIGN AREA REMOVE OPEN WIRE WHERE REQUIRED THROUGHOUT PREMIERS DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
WORKING SPACE INSUFFICIENT WORKING SPACE AT PANEL ENSURE WORKING SPACE WHERE REQUIRED THROUGHOUT PREMISES DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
CLOSE BOX OPENINGS MISSING PANEL FILLERS AT MAIN PANEL INSTALL FILLERS AT BOXES AND PANEL WHERE REQUIRED DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
DEFECTIVE DISTRIBUTION PANEL COVER IS MISSING SCREWS AND LOOSE ENSURE ALL DISTRIBUTION EQUIPMENT IN APPROVED CONDITION DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
PROPER SIZE GRD ELECTRODE COND NO VISIBLE WATER GROUND NO VISIBLE SUPPLEMENTAL GROUND ENSURE SERVICE GROUNDED IN APPROVED MANNER DANGEROUS AND HAZARDOUS 400 E 103RD ST COMPLAINT PASSED View
PANEL SCHEDULES PANEL SCHEDULES NOT LEGIBLE 400 E 103RD ST COMPLAINT PASSED View
PROVIDE PERMIT TO CORRECT VIOLATIONS AND FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES WIRE, DEVICES AND EQUIPMENT THROUGHOUT PREMISES ENTIRE SPACE BUILT OUT/REMODELED NO PERMITS (14A-4-404.6) 400 E 103RD ST COMPLAINT PASSED View
PROVIDE ANY REQUIRED ROUGH INSPECTIONS FOR THE INSTALLATION OF ELECTRICAL CONDUIT, BOXES WIRE, DEVICES AND EQUIPMENT THROUGHOUT PREMISES ENTIRE SPACE BUILT OUT/REMODELED NO PERMITS (14A-5-505.2) 400 E 103RD ST COMPLAINT PASSED View