Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PIGEONS-NESTING | ABATE PIGEON NUISANCE. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - APARTMENTS AND BOILER ROOM - UNVERIFIED DETECTORS AND CONDITIONS. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILING BY UTILITY AND LAUNDRY ROOM - PLASTER MISSING WITH EXPOSED WOOD LATH AND CEILING JOISTS.BL00831 | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2012. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
SELF-CLOSE CLASS B FIRE DOOR | 3300 - 02 N. INNER FOYER STAIRWAY DOOR AT GRADE - CLOSER - MISSING. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 3300 N. - INTERIOR STAIRWAY AT 1ST - BALUSTER MISSING. 2342 - 44 W. LOOSE BALUSTER AT TOP. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 3 - REAR - 3 STORY OPEN WOOD PORCHES - TWISTED COLUMNS . OPEN BEAM POCKETS - MISSING BRICKS AND MORTAR. LEDGER BEAMS ONLY PARTIALLY BOLTED TO BUILDING - MISSING BOLTS. DECK JOISTS ONLY NAILED TO HEADER JOISTS AND LEDGER BEAMS. MIDDLE NORTH PORCH - 2 X 6 JOIST HANGERS USED ON 2 X 10 JOISTS. PORCHES SWAY EXCESSIVELY. HANDRAILS - LOOSE. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
PARAPET | 3300 N/FRONT PARAPET WALL;FRACTURED MASONRY,WASHED OUT MORTAR. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | NORTH SCREEN DOORS AT PORCHES THROUGHOUT - CLOSERS MISSING THROUGHOUT. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING-NO RESPOSE UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED INTERIOR INSPECTION FOR 2023 ANNUAL INSPECTION. | 3300 N CLAREMONT AVE | PERIODIC | FAILED | View |