Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 1:23 AM
PIN: 13222230130000
Property Address: 4120 W ADDISON ST
City - Zip: CHICAGO - 60641
2023 Property Class: 315
2023 Township: 71 - Jefferson
2023 Neighborhood: 71074
2023 Tax District: 71128
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 44 Violations
Violation Inspector Comments Address Category Status View
STOP WORK UNTIL PERMIT HAS BEEN OBTAINED. SEC. 13-32-035; 13-12-080 4120 W ADDISON ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY GARDEN UNIT 4120 65 DEGREE 2ND FLR UNIT 4120 65 DEGREE 3RD FLR UNIT 4120 64 DEGREE 4120 W ADDISON ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 3RD FLR 4120 97 WATER TEMP 2ND FLOOR 4120 97 DEGREE WATER TEMP 4120 W ADDISON ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH & EAST SEVERE MORTAR JOINT EROSION SECTIONS, MOST NOTICEABLE ON THE EAST 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME WEST-ROTTED DOOR FRAMES AT GRADE LEAVING THEM DISCONNECTED 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR SILL 4124 STAIRWELL DOOR RUBS FRAME, THUS NO LATCHING TO SECURE (LOCK) 4120 W ADDISON ST PERIODIC FAILED View
REPUTTY WINDOW PANES 4124 2ND FLOOR MID-LANDING WINDOW WITH TORN WINDOW CORDS 4120 W ADDISON ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION PROVIDE FULL INTERIOR ACCESS, TO VERIFY SAFETY DETECTORS & OCCUPANCY 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH FREE STANDING WALL, NORTH SIDE HAS WASHED OUT MORTAR AND SPALLED BRICK. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME WEST-ROTTED DOOR FRAMES AT GRADE LEAVING THEM DISCONNECTED 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR DOOR SILL 4124 STAIRWELL DOOR RUBS FRAME, THUS NO LATCHING TO SECURE (LOCK) 4120 W ADDISON ST PERIODIC FAILED View
REPUTTY WINDOW PANES 4124 2ND FLOOR MID-LANDING WINDOW WITH TORN WINDOW CORDS 4120 W ADDISON ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION PROVIDE FULL INTERIOR ACCESS, TO VERIFY SAFETY DETECTORS & OCCUPANCY 4120 W ADDISON ST PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES, RAILS END POST TO WALL, FASTENED TO EXTERIOR WALL WITH NAILS ONLY,(BOTTOM). 4120 W ADDISON ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRS GRADE TO 1ST AT 4120, STAIR TREADS ARE LOOSE. 4120 W ADDISON ST PERIODIC FAILED View
STOP/REMOVE NUISANCE SOUTH-WEST CORNER HAS GRAFFITI. 4120 W ADDISON ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING, NOT REGISTERED YEAR 2005 THRU 2010. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH FREE STANDING WALL, NORTH SIDE HAS WASHED OUT MORTAR AND SPALLED BRICK. 4120 W ADDISON ST PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT AT 4120 STAIRWAY CEILINGS ALL LEVELS HAVE PEELING PAINT. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM INTERIOR STAIRS GRADE TO 1ST AT 4120, STAIR TREADS ARE LOOSE. 4120 W ADDISON ST PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING, MISSING OWNERS I.D. SIGN. 4120 W ADDISON ST PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING, MISSING OWNERS I.D. SIGN. 4120 W ADDISON ST PERIODIC FAILED View
STOP/REMOVE NUISANCE SOUTH-WEST CORNER HAS GRAFFITI. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH 4120 1ST FLOOR CRACKED STRINGER BOLT STRINGER INTO EXTERIOR WALLS 4124 2ND FLOOR DECK: FRONT JOIST WORN. 2ND FLOOR DECK BROKEN PROVIDE BOLTS FOR STRINGERS AND JOISTS NEXT TO EXTERIOR WALL. 4120 W ADDISON ST PERIODIC PASSED View
PERMIT REQUIRED - CONTRACTOR PERMIT FOR REPAIRS. 4120 W ADDISON ST PERIODIC PASSED View
REPAIR LINTELS 4120 ENTRYWAY - RUSTED AND DEFLECTING LINTEL, LIMESTONE ABOVE ENTRY IS FRACTURED. MASONRY PERMIT REQUIRED FOR REPAIRS. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION ABOVE 3RD FLOOR WINDOWS - BULGING, SHIFTING BRICKS, WASHED OUT MORTAR. MASONRY PERMIT REQUIRED. (NOTE: POSSIBLE LINTEL FAILURE - UNABLE TO INSPECT, LINTELS ARE WRAPPED IN METAL.) 4120 W ADDISON ST PERIODIC FAILED View
REPAIR WINDOW SILLS EAST, SOUTH AND WEST ELEVATION WINDOW SILLS - WASHED OUT MORTAR AT JOINTS. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR ROOF 4124 REAR PORCH ROOF - ROTTED WOOD. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR PORCH SYSTEM 2 - REAR 3 STORY WOOD PORCHES -DRY ROTTED WOOD.4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET IN HEIGHT.INNER 4X4 POST USED TO SUPPORT INNER STRINGERS, ARE NOT RUN CONTINOUSLY TO FOUNDATION AT GRADE, POST ARE NAILED TO 2X8 JOIST AND JOIST IS NAILED TO CENTER 4X4 COLUMN.2X8 BEAMS NAILED TO COLUMNS.4X4 COLUMNS NAILED AT LAP-JOINT.1X'S USED AS RISERS, SOME RISERS ARE BROKEN AT WINDERS.GUARDRAILS NAILED TO BUILDING.GUARDRAILS AT 3RD FLOOR ONLY 32 INCHES IN HEIGHT.PLANS AND PERMIT REQUIRED. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR PORCH SYSTEM 2 - REAR 3 STORY WOOD PORCHES -DRY ROTTED WOOD.4X4 COLUMNS USED FOR SUPPORT OVER 12 FEET IN HEIGHT.INNER 4X4 POST USED TO SUPPORT INNER STRINGERS, ARE NOT RUN CONTINOUSLY TO FOUNDATION AT GRADE, POST ARE NAILED TO 2X8 JOIST AND JOIST IS NAILED TO CENTER 4X4 COLUMN.2X8 BEAMS NAILED TO COLUMNS.4X4 COLUMNS NAILED AT LAP-JOINT.1X'S USED AS RISERS, SOME RISERS ARE BROKEN AT WINDERS.GUARDRAILS NAILED TO BUILDING.GUARDRAILS AT 3RD FLOOR ONLY 32 INCHES IN HEIGHT.PLANS AND PERMIT REQUIRED. 4120 W ADDISON ST PERIODIC FAILED View
REPAIR SKYLIGHT 4120 W. FRONT INTERIOR STAIRWAY/ SKYLIGHT - BROKEN PANE. 4120 W ADDISON ST PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING - NO RESPONSE, OWNER DOES NOT HAVE KEYS TO APARTMENTS. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS AND REAR PORCH. 4120 W ADDISON ST PERIODIC FAILED View
REMOVE BUILDING/BASEMENT BOILER ROOM-STORAGE OF MOTORCYCLE.REMOVE.(SECT.7-28-060). 4120 W ADDISON ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS BUILDING/TWO REAR ENCLOSED PORCHES,BASEMENT LAUNDRY AND BOILER ROOM-MISSING SMOKE DETECTORS. 4120 W ADDISON ST PERIODIC FAILED View
1-HR HEATING PLANT SEPARATION BASEMENT BOILER ROOM,HOLES IN CEILING AND SOUTH WALL PIPE PENETRATIONS. 4120 W ADDISON ST PERIODIC FAILED View
CARB MONOX DETECT IN RESID BASEMENT BOILER ROOM-MISSING CARBON MONOXIDE DETECTOR. 4120 W ADDISON ST PERIODIC FAILED View
NO GASOLINE(LPG) STORAGE BUILDING/BASEMENT BOILER ROOM,STORAGE OF GAS IN CANS AND SNOW BLOWERS,LAWN MOWERS. 4120 W ADDISON ST PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG BUILDING/FRONT INTERIOR STAIRWAYS-FIRE EXTINGUSHERS-MISSING TAGS. 4120 W ADDISON ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING/NO ENTRY TO APARTMENTS,UNVERIFIED DETECTORS,CONDITIONS. 4120 W ADDISON ST PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR SOUTH ELEVATION (REAR). ERECTED 3 STORY PORCH SYSTEM (SAME AS EXISTING) 4120 W ADDISON ST COMPLAINT FAILED View
FILE BLDG REGISTRATION BUILDING, NOT REGISTERED YEAR 2005 THRU 2010. 4120 W ADDISON ST PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT AT 4120 STAIRWAY CEILINGS ALL LEVELS HAVE PEELING PAINT. 4120 W ADDISON ST PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING/NOT REGISTERED FOR 2015,2016. 4120 W ADDISON ST PERIODIC FAILED View