Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING TO VERIFY DETECTORS, OCCUPANCY, OUTSTANDING VIOLATIONS PENDING INFERIOR STAIR SYSTEMS TO EXTERIOR SOUTH PORCH SYSTEM DURING ANNUAL INSPECTION | 4256 N BERNARD ST | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING IS NOT REGISTERED 2005-2007 | 4256 N BERNARD ST | PERIODIC | PASSED | View |
FLAM LIQ TANK FRONTAGE CONSENT | STORING FLAMMABLES -GAS IN LAUNDRY AND BOILER ROOM | 4256 N BERNARD ST | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT LAUNDRY ROOM -MISSING SMOKE DETECTOR. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT LAUNDRY ROOM MISSING CARBON MONOXIDE DETECTOR. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | LOOSE HANDRAILS | 4256 N BERNARD ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY-UNABLE TO DETERMINE BUILDING CONDITIONS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY-UNABLE TO DETERMINE BUILDING CONDITIONS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTHWEST EXTERIOR STAIR SYSTEM WITH CRUMBLY FOOTING. (2) UNANCHORED COLUMN AT GRADE, BUTT JOINTS, TOE NAILED. (3) ROTTING STRINGER AT CRITICAL ANCHORED AREA (WEST) OTHER NOT BOLTED, TAR-CON SCREWS AT WALL. (4) ROTTING AND WORN STAIR TREADS, NAIL HEADS PROTRUDING FROM FACE OF TREADS. 9"/4" WIDTH. (5) WEAK AND 36" IN HEIGHT - GUARDRAILS. (6) ROTTING AND OVER SPANNED BEAM 10'10" IN LENGTH. MISSING TIE SCRAPS. (7) FRONT HEADER JOISTS NOT BOLTED TO COLUMNS. EAST SYSTEM WITH SIMILAR FAULTS. PERMIT REQUIRED TO REPLACE OR UPGRADE SYSTEM COMPONENTS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
SEPARATE CIRCUIT FOR APPLIANCE | BASEMENT - SEAL HOLES AND PIPE PENETRATIONS, WALL SEPARATING BOILER AND LAUNDRY AREA. | 4256 N BERNARD ST | PERIODIC | PASSED | View |
INT WALL/CEILING CHIP PLASTER | LAUNDRY/STORAGE ROOM WITH HOLES ON PLASTER CEILINGS. | 4256 N BERNARD ST | PERIODIC | PASSED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER¿S INFORMATION | 4256 N BERNARD ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | PARAPET ON CULLOM ST SIDE 3441-43, ABOVE TRIVIEW WINDOW, - SOLDIER COURSE START BULGING OUT, LIME STONE START SHIFTING, - PERMIT IS REQUIRED TO REPAIR PARAPET. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
REPAIR LINTELS | STEEL LINTELS ABOVE 3RD FLOOR WINDOWS ARE SEVERELY RUSTED AND DELAMINATED, LINTELS ARE DEFLECTING WITH GAPS ABOVE, AND PERMIT IS REQUIRED FOR REPAIRS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | AT 4TH FLOOR CORNER PORCH HAND RAIL IS POOLY SCREW, HAND RAIL IS LOOSE, - 1ST ,2N AND 3RD FLOORS WINDER TYPE STAIR CASE STRINGER IS CONNECTING WITH UPPER STRINGER FOR THE STAIR, THE WOOD CONNECTION IS WEAK AND MIGHT FAIL UNDER HEAVY LOADS OR IN CASE OF AN EMERGENCY, - 2ND PORCH (CENTER) HAS THE SAME PROBLEM DESCRIBE ABOVE, - BOTH PORCH(S) AT ROOF LEVEL, - 6X6 COLUMN CONNECTING WITH 6X6 BEAM JUST NAIL, - 6X6 ROOF BEAM NOT ATTACHED TO MASONRY, - PERMIT IS REQUIRED TO REPAIR BOTH PORCH (S) | 4256 N BERNARD ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | LAUNDRY FACILITY IN DINGY CONDITION. | 4256 N BERNARD ST | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | SOUTHWEST PORCH-3STY OPEN WOOD PORCH -LOOSE , DEFLECTING HANDRAILS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | MISSING EXTERIOR TRIM ON WINDOWS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | MISSING EXTERIOR TRIM ON WINDOWS. | 4256 N BERNARD ST | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REMOVE PLANTS AND FURNITURE OBSTRUCTING EGRESS IN CASE OF EMERGENCY. | 4256 N BERNARD ST | PERIODIC | FAILED | View |