Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 12:09 PM
PIN: 13144100220000
Property Address: 4256 N BERNARD ST
City - Zip: CHICAGO - 60618
2023 Property Class: 315
2023 Township: 71 - Jefferson
2023 Neighborhood: 71082
2023 Tax District: 71128
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 20 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR OF BUILDING TO VERIFY DETECTORS, OCCUPANCY, OUTSTANDING VIOLATIONS PENDING INFERIOR STAIR SYSTEMS TO EXTERIOR SOUTH PORCH SYSTEM DURING ANNUAL INSPECTION 4256 N BERNARD ST PERIODIC PASSED View
POST OWNER/MANAGERS NAME/# BUILDING IS NOT REGISTERED 2005-2007 4256 N BERNARD ST PERIODIC PASSED View
FLAM LIQ TANK FRONTAGE CONSENT STORING FLAMMABLES -GAS IN LAUNDRY AND BOILER ROOM 4256 N BERNARD ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS BASEMENT LAUNDRY ROOM -MISSING SMOKE DETECTOR. 4256 N BERNARD ST PERIODIC FAILED View
CARB MONOX DETECT IN RESID BASEMENT LAUNDRY ROOM MISSING CARBON MONOXIDE DETECTOR. 4256 N BERNARD ST PERIODIC FAILED View
REPAIR PORCH SYSTEM LOOSE HANDRAILS 4256 N BERNARD ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY-UNABLE TO DETERMINE BUILDING CONDITIONS. 4256 N BERNARD ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY-UNABLE TO DETERMINE BUILDING CONDITIONS. 4256 N BERNARD ST PERIODIC FAILED View
REPAIR EXTERIOR STAIR SOUTHWEST EXTERIOR STAIR SYSTEM WITH CRUMBLY FOOTING. (2) UNANCHORED COLUMN AT GRADE, BUTT JOINTS, TOE NAILED. (3) ROTTING STRINGER AT CRITICAL ANCHORED AREA (WEST) OTHER NOT BOLTED, TAR-CON SCREWS AT WALL. (4) ROTTING AND WORN STAIR TREADS, NAIL HEADS PROTRUDING FROM FACE OF TREADS. 9"/4" WIDTH. (5) WEAK AND 36" IN HEIGHT - GUARDRAILS. (6) ROTTING AND OVER SPANNED BEAM 10'10" IN LENGTH. MISSING TIE SCRAPS. (7) FRONT HEADER JOISTS NOT BOLTED TO COLUMNS. EAST SYSTEM WITH SIMILAR FAULTS. PERMIT REQUIRED TO REPLACE OR UPGRADE SYSTEM COMPONENTS. 4256 N BERNARD ST PERIODIC FAILED View
SEPARATE CIRCUIT FOR APPLIANCE BASEMENT - SEAL HOLES AND PIPE PENETRATIONS, WALL SEPARATING BOILER AND LAUNDRY AREA. 4256 N BERNARD ST PERIODIC PASSED View
INT WALL/CEILING CHIP PLASTER LAUNDRY/STORAGE ROOM WITH HOLES ON PLASTER CEILINGS. 4256 N BERNARD ST PERIODIC PASSED View
POST OWNER/MANAGERS NAME/# MISSING OWNER¿S INFORMATION 4256 N BERNARD ST PERIODIC FAILED View
REPAIR EXTERIOR WALL PARAPET ON CULLOM ST SIDE 3441-43, ABOVE TRIVIEW WINDOW, - SOLDIER COURSE START BULGING OUT, LIME STONE START SHIFTING, - PERMIT IS REQUIRED TO REPAIR PARAPET. 4256 N BERNARD ST PERIODIC FAILED View
REPAIR LINTELS STEEL LINTELS ABOVE 3RD FLOOR WINDOWS ARE SEVERELY RUSTED AND DELAMINATED, LINTELS ARE DEFLECTING WITH GAPS ABOVE, AND PERMIT IS REQUIRED FOR REPAIRS. 4256 N BERNARD ST PERIODIC FAILED View
REPAIR PORCH SYSTEM AT 4TH FLOOR CORNER PORCH HAND RAIL IS POOLY SCREW, HAND RAIL IS LOOSE, - 1ST ,2N AND 3RD FLOORS WINDER TYPE STAIR CASE STRINGER IS CONNECTING WITH UPPER STRINGER FOR THE STAIR, THE WOOD CONNECTION IS WEAK AND MIGHT FAIL UNDER HEAVY LOADS OR IN CASE OF AN EMERGENCY, - 2ND PORCH (CENTER) HAS THE SAME PROBLEM DESCRIBE ABOVE, - BOTH PORCH(S) AT ROOF LEVEL, - 6X6 COLUMN CONNECTING WITH 6X6 BEAM JUST NAIL, - 6X6 ROOF BEAM NOT ATTACHED TO MASONRY, - PERMIT IS REQUIRED TO REPAIR BOTH PORCH (S) 4256 N BERNARD ST PERIODIC FAILED View
STOP/REMOVE NUISANCE LAUNDRY FACILITY IN DINGY CONDITION. 4256 N BERNARD ST PERIODIC PASSED View
REPAIR PORCH SYSTEM SOUTHWEST PORCH-3STY OPEN WOOD PORCH -LOOSE , DEFLECTING HANDRAILS. 4256 N BERNARD ST PERIODIC FAILED View
MAINTAIN WINDOW MISSING EXTERIOR TRIM ON WINDOWS. 4256 N BERNARD ST PERIODIC FAILED View
MAINTAIN WINDOW MISSING EXTERIOR TRIM ON WINDOWS. 4256 N BERNARD ST PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY REMOVE PLANTS AND FURNITURE OBSTRUCTING EGRESS IN CASE OF EMERGENCY. 4256 N BERNARD ST PERIODIC FAILED View