Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | JOISTS UNDERSIZED FOR SPAN. MISSING JOIST HANGERS VARIOUS LOCATIONS UNDERSIZED LEDGER UNDER 2 NORTH END NOT BOLTED. UNDERSIZED RAILING, PICKETS INSTALLED ON OUTSIDE OF SYSTEM, INSUFFICIENT STRINGER TO OTHER WOOD MEMBER CONNECTIONS. INSUFFICIENT. RAILING AND ANCHORS, CPLUMNS NOTCHED AND IN CLOSE PROXIMITY. INSUFFICIENT BEAM TO COLUMN CONNECTIONS LOOSE HANDRAIL TO 3 AND BROKEN PICKETS. LOOSE AND DEFLECTING RAILS REAR PORCH SYSTEM HAS MANY DETEICIENCES IN MATERIAL SIZE AND CONSTRUCTION. FULL PLANS AND PERMITS REQUIRED. | 716 W GRACE ST | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRACTURED AND BUCKLED SERVICE WALK WEST. | 716 W GRACE ST | PERIODIC | FAILED | View |
PARAPET | WASHED OUT MORTAR. | 716 W GRACE ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | CEILING HAS PEELING, FLAKING PAINT. | 716 W GRACE ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | HANDRAIL-MISSING PICKETS. | 716 W GRACE ST | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY-UNABLE TO DETERMINE BUILDING CONDITIONS. | 716 W GRACE ST | PERIODIC | FAILED | View |
INT WALL/CEILING PEELING PAINT | CEILING HAS PEELING, FLAKING PAINT. | 716 W GRACE ST | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | HANDRAIL-MISSING PICKETS. | 716 W GRACE ST | PERIODIC | FAILED | View |