Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 2:18 AM
PIN: 20043160010000
Property Address: 4435 S WALLACE ST
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72052
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 21 Violations
Violation Inspector Comments Address Category Status View
PROVIDE GUTTER & DOWNSPOUT NORTH AND SOUTH ELEVATION / GUTTERS - MISSING . 4435 S WALLACE ST COMPLAINT FAILED View
FOUNDATION, ADEQUATELY SUPPORT REAR OF BUILDING /FOUNDATION - LARGE CRACK.NORTH ELEVATION /BASEMENT FOUNDATION - LARGE SECTION LEANING IN . PLANS AND PERMIT REQUIRED TO REPAIR FOUNDATION IN BASEMENT . 4435 S WALLACE ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID FRONT / 2ND FL APT / CARBON MONOXIDE - MISSING BASEMENT / CARBON MONOXIDE MISSING . 4435 S WALLACE ST COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE 1ST AND 2ND FL / VIEWING DEVICE - MISSING. 4435 S WALLACE ST COMPLAINT FAILED View
EXPOSED WIRING FRONT INTERIOR STAIR / EXPOSE WIRE - 2ND FL CEILING .BASEMENT / CEILING - EXPOSE WIRES. 4435 S WALLACE ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT / SMOKE DETECTOR - MISSING FRONT INTERIOR STAIR / SMOKE DETECTOR MISSING FRONT 2ND FL APT / SMOKE DETECTOR - MISSING 4435 S WALLACE ST COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT / DOUBLE KEY LOCK - AT 1ST FL EXTERIOR DOOR 4435 S WALLACE ST COMPLAINT FAILED View
REPAIR BALCONY REAR / BALCONY - 2ND FLLEDGER BOARD NOT SEEN .JOIST NAILED TO HEADER.JOIST 24 ON CENTER GUARDRAILS NAILED TO GUARDRAILSPERMIT REQUIRED FOR BALCONY REPAIRS . 4435 S WALLACE ST COMPLAINT FAILED View
REPLACE D&H PORCH REAR /EXTERIOR PORCH GRADE TO 1ST FL .GUARDRAILS HANGING DOWN AND NAILED ONLY ONE SIDE.GUARDRAILS ALL LOOSE AND PICKETS MISSING .PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH .NORTH ELEVATION / EXTERIOR PORCH - GRADE TO 2ND FL ALL TREADS ROTTED.LEDGER BOARD NAILED ONLY JOIST NAILED ONLY LANDING HAS 2X4 USED AS BEAM COLUMNS ERECTED ON SERVICE WALK .GUARD RAILS AND STRINGER NAILED ONLY TO COLUMNS ,HEADERS AND WALL .PLANS AND PERMIT REQUIRED TO REPAIR BOTH PORCHES. 4435 S WALLACE ST COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 1ST FL APT / REAR SMOKE DETECTOR - OUT OF SERVICE . 4435 S WALLACE ST COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT / CEILING - EXPOSE JOIST 4435 S WALLACE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR FRONT INTERIOR STAIR / INTERIOR ALTERATION - 2ND FL MADE LANDING SMALLER .PLANS AND PERMIT REQUIRED FOR 2ND FL INTERIOR STAIR ALTERATIONS . 4435 S WALLACE ST COMPLAINT FAILED View
REPAIR BALCONY EAST BALCONY SECOND FLOOR - LEDGER BOARD NOT SEEN. JOISTS NAILED TO HEADER. JOIST ONLY 24" ON CENTER. GUARD RAILS ONLY FASTENED WITH NAILS AND MISSING BRACKETS. PLANS AND PERMITS REQUIRED TO REPLACE/REPAIR BALCONY. 4435 S WALLACE ST COMPLAINT FAILED View
FOUNDATION, ADEQUATELY SUPPORT EAST AND NORTH ELEVATION/FOUNDATION WALL - WALL SECTION LEANING WITH LARGE CRACK. PLANS AND PERMIT REQUIRED TO REPAIR FOUNDATION WALL. 4435 S WALLACE ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT, FRONT INTERIOR STAIRWAY, APARTMENT-1R, AND APARTMENT-2F - SMOKE DETECTORS MISSING. 4435 S WALLACE ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR NORTHWEST OPEN WOOD STAIR FROM FIRST FLOOR TO SECOND FLOOR -(1) ALL WOOD IN VARYING STAGES OF ROTT WITH JOINTS PULLING CREATING GAPS THAT EXPOSE RUSTING NAILS(2) JOIST HANGERS AND BOLTED CONNECTIONS MISSING(3) 2ND FLOOR LANDING MISSING COLUMN AND ONLY SUPPORTED BY ONE 2X6 WOOD KICKER(4) STRINGERS BOLTED CONNECTIONS TO POST, THE EXTERIOR WALL AND DECK HEADERS ARE MISSING(5) STEPS MISSING RISER BOARDS AND UNSUPPORTED TREADS SAG AND EXCESSIVELY BOUNCES WHEN WALKED ON(6) STAIR HANDRAILS ARE ONLY 30INCHES HIGH (7) PLANS AND PERMITS REQUIRED 4435 S WALLACE ST COMPLAINT FAILED View
REPAIR EXTERIOR PLATFORM REAR ELEVATION FIRST FLOOR CONCRETE PLATEFORM GUARDRAILS -(1) ALL MEMBERS AT DIFFERENT STAGES OF ROTT(2) ALL CONNECTIONS ARE ONLY FACE NAILED OR TOE NAILED WITH THE EDGES OF WOOD MEMBERS ROTTING AND PULLING AWAY EXPOSING RUSTING NAILS(3) WEAK GUARDRAILS ARE ONLY 28 INCHES HIGH(4) PLANS AND PERMITS REQUIRED 4435 S WALLACE ST COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT NORTH AND SOUTH ROOF EAVES - GUTTERS MISSING 4435 S WALLACE ST COMPLAINT FAILED View
REPAIR STOOP WEST ELEVATION SOUTH END 3 CONCRETE STEPS FROM GRADE TO FIRST FLOOR - HANDRAIL MISSING 4435 S WALLACE ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT AND APARTMENT 2F - CARBON MONOXIDE DETECTORS MISSING. 4435 S WALLACE ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR EAST ELEVATION/INTERIOR STAIRWAY AT SECOND FLOOR - SECOND FLOOR LANDING MADE SMALLER. PLANS AND PERMIT REQUIRED FOR ALTERATION TO SECOND FLOOR LANDING. 4435 S WALLACE ST COMPLAINT FAILED View