The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNERS I.D. SIGN POSTED | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT PORCH SEVERALLY ROTTED. 6X6 COULMNS, CRACKED TWISTED RIM JOINT ARE ROTTED, STAIRS ARE SEVERLY OUT OF LEVEL BROKEN, UNSTABLE MISSING PICKETS THUR OUT.OBTAIN PERMIT FOR REPLACE OF FRONT PORCH. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | SOUTH ELEV. LARGE GAP AT GRADE LEVEL | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO VERIFY DECT. OCCUPANCY AND INSPECT REAR PORCH AND COMPLAINT ABOUT ONE ONLY | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SR#07-01184396 BASEMENT DEFECTIVE SMOKE DETECTOR | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT MISSING CARBON MONOXIDE DETECTOR | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST EXTERIOR STAIRS GUARD RAILS ARE 32", ROTTED COLUMN, LOOSE HANDRAILS, SHAKY STAIRS, WEST EXTERIOR STAIR BALUSTERS ARE HORIZONTAL AND APPROX. 7-10" APART | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE: ROTTED EAVER, PEELING PAINT, DETERIORATED ROOFING MATERIAL | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRICAL INSTALLED IN THE ATTIC BASEMENT AND EAST PORCH WITHOUT A PERMIT | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT-ATTIC AND EAST PORCH-BASEMENT AND ATTIC ORIGINAL USE WAS FOR STORAGE NOW BASEMENT HAS 1 ILLEGAL DWELLING UNIT AND 2 ROOMING UNITS, ATTIC HAS 1 ILLEGAL DWELLING UNIT-EAST PORCH AT 1ST AND 2ND NOW HAVE 1 BATHROOM PER FLOOR, 1 FLOOR ORIGINAL 1 DU NOW HAS 1 DWELLING UNIT AND 2 ROOMING UNITS-2ND FLOOR ORIGINAL 1 DU, NOW HAS 2 DU | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
STAIRWELL ENCLOSURE | ATTIC, EAST STAIRWAY ENCLOSURE NOT 1 HOUR | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
WINDOW AREA ABOVE GROUND | BASEMENT DU INSUFFICIENT NATURAL LIGHT AND VENTILATION | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
SEPARATION OF DWELLING ADEQUAT | BASEMENT CEILING IS 1/2" DRYWALL OR EXPOSED JOISTS | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
EGRESS -BASEMENT | BASEMENT EXIT IS THRU STORAGE AREA | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | VESTIBULE: MISSING LIGHT FIXTURE | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | 1ST FLR. THRU OUT ROTTED WINDOW FRAMES. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | 1ST FLR. THRU OUT ROTTED SASH | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | 1ST FLR. THRU OUT CRACKED/MISSING PUTTY. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1645, 2ND FLOOR, REAR, ATTIC: NO SMOKE DETECTOR | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1645, 2ND FLOOR, REAR & ATTIC: NO CARBON MONOXIDE DETECTOR | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1645, 2ND FLOOR: COMMON FORCED AIR, ATTIC SPACE HEATER BROKEN | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1645, 2ND FLOOR, REAR (COMMON PLANT) FORCED AIR, ATTIC, BROKEN SPACE HEATER | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1645, 2ND FLOOR, REAR: USING COOKING GAS FOR HEAT | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 1645 N CENTRAL PARK AVE | COMPLAINT | CLOSED | View | |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE.UNABLE TO GAIN ENTRY TO VERIFY COMPLAINT OF OCCUPANCY,NO WINDOWS OR EXITS. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | YARD JUNK | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS: MISSING WINDOW SCREENS | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ATTIC AND REAR PORCH: MISSING SMOKE DETECTOR | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
LIGHT AND VENT | ATTIC DU DOES NOT HAVE WINDOWS | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
EGRESS | ATTIC HAS 1 EXIT | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST PORCH ENCLOSED WITH PARTICLE BOARD NOT 1 HOUR; PROVIDE PERMIT | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD - ABANDONED CAR. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMEN, 1ST AND 2ND FLOORS - MISSING CARBON MONOXISE ALARMS,(14X-5-504.9, 14B-9915.1.1, 14B-9-915.2, AND 14R-11-1105) | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY AND BASEMWNT - MISSNG SMOKE ALARMS. 1ST AND 2ND FLOORS MISSING SECOND SMOKE ALARM. NEAR FRONT BEDROOMS.(14X-5-504.8, 14X-5-504.8.4, 14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, AND 14R-11-1104) | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | BASEMENT APARTMENT AND SEPERATE ROOM UNITS - REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) IN THE BASEMENT INSTALLED WITHOUT A PERMIT. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | SOUTH REAR - MISSING SECTION OF GUTTER. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS - UNEVEN RISERS, ALL JOISTS HAVE ONLY ONE NAIL. PERMIT REQUIRED FOR REPAIRS. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1645 N CENTRAL PARK AVE | COMPLAINT | FAILED | View |