Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR ROOF | SOUTH , WEST , AND NORTH ROOF - WORN , MISSING , AND LOOSE SHINGLES. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS - EAVES - ROTTED , LOOSE AND FALLING SOFFIT AND FACIA. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | NORTH PORCH ROOF SAGGING. SOUTH AND WEST ROOF ROTTED AND COLLAPSING. ROTTED RAFTERS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS - GRADE TO 1ST - FRACTURED AND BROKEN CONCRETE. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH 1 STORY WOOD PORCH - 6 X 6 COLUMNS SITTING ON SOIL - FOUNDATION STATUS UNKNOWN. 6 X 6 BEAMS SHIFTING INSIDE FIRE CUTS. UNDERSIZED 2 X 8 JOISTS OVERSPANNED AT 13' . DECK JOISTS ONLY NAILED TO RIM AND HEADER JOISTS. STRINGERS ONLY NAILED TO HEADER JOISTS. LADDER TYPE GUARDRAILS WITH 12'' SPACING BETWEEN TIES . PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST SERVICE WALK - BROKEN AND MISSING CONCRETE. WEST SERVICE WALK - BROKEN AND COLLAPSING CONCRETE. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR GUTTER | ALL ELEVATIONS - GUTTERS RUSTED WITH HOLES. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST AT 1ST - WINDOW - BROKEN PANE. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN -MISSING. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | NORTH PORCHES AT GRADE - STORING TIRES UNDER PORCHES - FIRE HAZARD. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | WEST ROOF STRUCTURE - LOOSE AND COLLAPSING SHEATHING WITH ROTTED RAFTERS AND ROOF JOISTS - DANGEROUS AND HAZARDOUS. OTHER ROOF AREAS - SAGGING AND COLLAPSING SECTIONS . | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR ROOF | SOUTH , WEST, AND EAST - ROOF - ROOFING MATERIAL - BROKEN , LOOSE , MISSING , AND FALLING. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS OF EAVES - SOFFIT SECTIONS - ROTTED , LOOSE , BROKEN , AND FALLING - DANGEROUS AND HAZARDOUS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR GUTTER | ALL ELEVATIONS - GUTTERS - RUSTED THROUGHOUT. NORTH AND EAST GUTTERS CLOGGED WITH WEEDS. EAST SECTION OF GUTTER LOOSE . NORTH GUTTER SAGGING. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST AND WEST SERVICE WALKS - BROKEN , CRACKED , AND UNEVEN CONCRETE SURFACES - TRIP HAZARD. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST AT 2ND - CRACKED WINDOW PANE. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | HEATING SYSTEM OFF AT TIME OF INSPECTION. GAS SHUT OFF. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER FURNISHED, GAS SHUT OFF. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR IN BASEMENT. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | AIR SEEPAGE AT PLEXIGLASS WINDOWS AT WEST ELEVATION ON FIRST FLOOR. ALSO AIR SEEPAGE AT FRONT AND REAR DOORS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR HAS LOW BATTERY ON 2ND LEVEL. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
INSECTS | KNAT INFESTATION OBSERVED IN THE WEST DWELLING UNIT ON ALL LEVELS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | HEATING SYSTEM OFF AT TIME OF INSPECTION. GAS SHUT OFF. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER FURNISHED, GAS SHUT OFF. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR IN BASEMENT. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | AIR SEEPAGE AT PLEXIGLASS WINDOWS AT WEST ELEVATION ON FIRST FLOOR. ALSO AIR SEEPAGE AT FRONT AND REAR DOORS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR HAS LOW BATTERY ON 2ND LEVEL. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | STUCCO ON EAST AND WEST ELEVATIONS DETERIORATING BADLY, STRESS CRACK EXTENSIVE AND OPEN. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR ROOF | SHINGLES AT THE SOUTH ELEVATION HAVE DETERIORATED AND OPEN SECTIONS ON THE ROOF. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR GUTTER | GUTTERS NEED TO BE CLEANED AND REMOVE WEEDS THAT ARE GROWING TO ALLOW GUTTER ON THE SOUTH ELEVATION AND NORTH ELEVATION TO WORK PROPERLY. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRACTURED AND BROKEN CONCRETE SIDEWALK ON EAST AND WEST ELEVATIONS, TRIP HAZARD. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | NO SAFETY RAILS ON THE INTERIOR STAIR SYSTEM LEADING TO THE SECOND FLOOR IN THE WEST DWELLING UNIT. DANGEROUS AND HAZARDOUS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
PERMIT REQUIRED | OBTAIN PERMIT FOR DRYWALLING AND REPAIRING ANY MORE WALLS. OBTAIN PERMIT FOR WORK DONE ON REAR ENCLOSED PORCH ON THE NORTHWEST ELEVATION. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | 1136 FIRST FLOOR - KITCHEN SINK - INSTALL AIR CHAMBERS ON THE HOT AND COLD WATER LINES. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | 1136 FIRST FLOOR - KITCHEN SINK - REPLACE FLEXIBLE WATER SUPPLIES WITH COPPER SUPPLIES. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE TRAP | BASEMENT - LAUNDRY TUB TRAP, MADE WITH WATER FITTINGS, REPLACE WITH A TUBULAR TRAP. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
PRV CLEANOUT AT BASE OF STACK | BASEMENT - INSTALL FULL SIZE CLEAN OUT ON THE THREE INCH PVC STACK. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | SECOND FLOOR - TUB SPOUT AWAY FROM WALL, INSTALL PROPERLY. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | SECOND FLOOR - TUB ENAMEL CHIPPED IN NUMEROUS SPOTS, REPAIR OR REPLACE. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | METER BOX NOT SECURED TO EXTENSION WALL PROPERLY. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | REPLACE SERVICE ENTRANCE CABLE RISER BURIED BEHIND SIDING OF BUILDING. *DANGEROUS AND HAZARDOUS* | 1136 W 104TH PL | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | OPEN PANEL WITH EXPOSED LIVE PARTS - PANEL COVERS MISSING. *DANGEROUS AND HAZARDOUS* | 1136 W 104TH PL | COMPLAINT | FAILED | View |
PROPER SIZE OCP | PROVIDE OVER CURRENT PROTECTION FOR PANEL BEING FED BY BARE WIRES BETWEEN BASEMENT AREAS. *DANGEROUS AND HAZARDOUS* | 1136 W 104TH PL | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR BARE WIRES FROM BASEMENT AREA 1134 PANEL TO BASEMENT AREA OF 1136 PANEL - AND 1136 SECOND FLOOR BATHROOM HAS BARE WIRES FROM LIGHT FIXTURE THROUGH WALL TO UNKNOWN LOCATION. *DANGEROUS AND HAZARDOUS CONDITION* | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOP AREA, BATHROOM, AND LAUNDRY AREAS, AND REAR EXTERIOR RECEPTACLES. 18-27-210.8, 18-27-570.8. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
PROVIDE WEATHERPROOF BOXES, LIGHTS, FITTINGS, AND APPROVED RACEWAY FOR ALL FRONT AND REAR EXTERIOR AREAS. 18-27-110.11. | 1136 W 104TH PL | COMPLAINT | FAILED | View | |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREA, AND GARAGE. 18-27-210.25. | 1136 W 104TH PL | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | SERVICE DISCONNECTS SHALL BE ONE TO SIX DISCONNECTS IN A COMMON ENCLOSURE. 18-27-230.71. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
WIRING METHODS - SINCE BUILDING IS BEING FED BY ONE PHASE AND BRANCH CIRCUITS SHARE NEUTRALS IT IS POSSIBLE DUE TO SHARED NEUTRALS TO BE OVERLOADED AND CAUSE OF ELECTRICAL SHORT OR LOSS OF NEUTRAL WHICH RESULTS IN A DANGEROUS AND HAZARDOUS CONDITION. 18-27-110.8. | 1136 W 104TH PL | COMPLAINT | FAILED | View | |
PROVIDE A WATER MAIN GROUND CONDUCTOR TO WITHIN 5 FEET OF WATER METER OR VALVE. 18-27-250.2. | 1136 W 104TH PL | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | PROPERLY BOND ALL SERVICE DISCONNECTS AND ELECTRICAL PANELS ACCORDING TO ARTICLE 250.2 - PANELS HAVE BARE WIRES WITH NO CONDUIT RUNS BETWEEN PANELS, 18-27-250.2. *DANGEROUS AND HAZARDOUS CONDITION* | 1136 W 104TH PL | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | REMOVE ALL ABANDONED RACEWAY, BOXES, CABLE, AND ELECTRICAL EQUIPMENT AT 1136 REAR EXTERIOR AREAS OF BUILDING. 18-27-110.12E. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. 13-12-360. | 1136 W 104TH PL | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE TRAP | 1136 FIRST FLOOR - KITCHEN SINK - REMOVE FLEXIBLE WASTE PIPE AND REPIPE WITH RIGID TUBING. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | EAST GUTTER SECTION - MISSING AND LAYING ON GROUND. EAST DOWNSPOUT - MISSING. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTHWEST AT 1ST - STORM DOOR WITH BROKEN WINDOW PANE. | 1136 W 104TH PL | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH PORCHES -OPEN AND PARTIALLY ENCLOSED - COLUMNS ERECTED ON CONCRETE BLOCKS - FOUNDATION STATUS UNKNOWN. UNDERSIZED 2 X 8 DECK JOISTS OVERSPANNED AT 13' . BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. NORTHWEST DECKING - ROTTED AND SAGGING. GUARD AND HANDRAILS - ''LADDER'' TYPE WITH 10'' TO 13'' BETWEEN HORIZONTAL TIES. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. | 1136 W 104TH PL | COMPLAINT | FAILED | View |