Chicago Building Violations Data: 62 Violations
Violation Inspector Comments Address Category Status View
REPAIR ROOF SOUTH , WEST , AND NORTH ROOF - WORN , MISSING , AND LOOSE SHINGLES. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR EAVES ALL ELEVATIONS - EAVES - ROTTED , LOOSE AND FALLING SOFFIT AND FACIA. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR ROOF STRUCTURE NORTH PORCH ROOF SAGGING. SOUTH AND WEST ROOF ROTTED AND COLLAPSING. ROTTED RAFTERS. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT STAIRS - GRADE TO 1ST - FRACTURED AND BROKEN CONCRETE. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH 1 STORY WOOD PORCH - 6 X 6 COLUMNS SITTING ON SOIL - FOUNDATION STATUS UNKNOWN. 6 X 6 BEAMS SHIFTING INSIDE FIRE CUTS. UNDERSIZED 2 X 8 JOISTS OVERSPANNED AT 13' . DECK JOISTS ONLY NAILED TO RIM AND HEADER JOISTS. STRINGERS ONLY NAILED TO HEADER JOISTS. LADDER TYPE GUARDRAILS WITH 12'' SPACING BETWEEN TIES . PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. 1136 W 104TH PL COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY EAST SERVICE WALK - BROKEN AND MISSING CONCRETE. WEST SERVICE WALK - BROKEN AND COLLAPSING CONCRETE. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR GUTTER ALL ELEVATIONS - GUTTERS RUSTED WITH HOLES. 1136 W 104TH PL COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST AT 1ST - WINDOW - BROKEN PANE. 1136 W 104TH PL COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. 1136 W 104TH PL COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S ID SIGN -MISSING. 1136 W 104TH PL COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR NORTH PORCHES AT GRADE - STORING TIRES UNDER PORCHES - FIRE HAZARD. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR ROOF STRUCTURE WEST ROOF STRUCTURE - LOOSE AND COLLAPSING SHEATHING WITH ROTTED RAFTERS AND ROOF JOISTS - DANGEROUS AND HAZARDOUS. OTHER ROOF AREAS - SAGGING AND COLLAPSING SECTIONS . 1136 W 104TH PL COMPLAINT FAILED View
REPAIR ROOF SOUTH , WEST, AND EAST - ROOF - ROOFING MATERIAL - BROKEN , LOOSE , MISSING , AND FALLING. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR EAVES ALL ELEVATIONS OF EAVES - SOFFIT SECTIONS - ROTTED , LOOSE , BROKEN , AND FALLING - DANGEROUS AND HAZARDOUS. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR GUTTER ALL ELEVATIONS - GUTTERS - RUSTED THROUGHOUT. NORTH AND EAST GUTTERS CLOGGED WITH WEEDS. EAST SECTION OF GUTTER LOOSE . NORTH GUTTER SAGGING. 1136 W 104TH PL COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY EAST AND WEST SERVICE WALKS - BROKEN , CRACKED , AND UNEVEN CONCRETE SURFACES - TRIP HAZARD. 1136 W 104TH PL COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST AT 2ND - CRACKED WINDOW PANE. 1136 W 104TH PL COMPLAINT FAILED View
SAFE WORKING CONDITIONS HEATING SYSTEM OFF AT TIME OF INSPECTION. GAS SHUT OFF. 1136 W 104TH PL COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER FURNISHED, GAS SHUT OFF. 1136 W 104TH PL COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR IN BASEMENT. 1136 W 104TH PL COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR. 1136 W 104TH PL COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE AIR SEEPAGE AT PLEXIGLASS WINDOWS AT WEST ELEVATION ON FIRST FLOOR. ALSO AIR SEEPAGE AT FRONT AND REAR DOORS. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTOR HAS LOW BATTERY ON 2ND LEVEL. 1136 W 104TH PL COMPLAINT FAILED View
INSECTS KNAT INFESTATION OBSERVED IN THE WEST DWELLING UNIT ON ALL LEVELS. 1136 W 104TH PL COMPLAINT FAILED View
SAFE WORKING CONDITIONS HEATING SYSTEM OFF AT TIME OF INSPECTION. GAS SHUT OFF. 1136 W 104TH PL COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG NO HOT WATER FURNISHED, GAS SHUT OFF. 1136 W 104TH PL COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR IN BASEMENT. 1136 W 104TH PL COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTOR. 1136 W 104TH PL COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE AIR SEEPAGE AT PLEXIGLASS WINDOWS AT WEST ELEVATION ON FIRST FLOOR. ALSO AIR SEEPAGE AT FRONT AND REAR DOORS. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTOR HAS LOW BATTERY ON 2ND LEVEL. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR EXTERIOR WALL STUCCO ON EAST AND WEST ELEVATIONS DETERIORATING BADLY, STRESS CRACK EXTENSIVE AND OPEN. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR ROOF SHINGLES AT THE SOUTH ELEVATION HAVE DETERIORATED AND OPEN SECTIONS ON THE ROOF. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR GUTTER GUTTERS NEED TO BE CLEANED AND REMOVE WEEDS THAT ARE GROWING TO ALLOW GUTTER ON THE SOUTH ELEVATION AND NORTH ELEVATION TO WORK PROPERLY. 1136 W 104TH PL COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY FRACTURED AND BROKEN CONCRETE SIDEWALK ON EAST AND WEST ELEVATIONS, TRIP HAZARD. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM NO SAFETY RAILS ON THE INTERIOR STAIR SYSTEM LEADING TO THE SECOND FLOOR IN THE WEST DWELLING UNIT. DANGEROUS AND HAZARDOUS. 1136 W 104TH PL COMPLAINT FAILED View
PERMIT REQUIRED OBTAIN PERMIT FOR DRYWALLING AND REPAIRING ANY MORE WALLS. OBTAIN PERMIT FOR WORK DONE ON REAR ENCLOSED PORCH ON THE NORTHWEST ELEVATION. 1136 W 104TH PL COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING 1136 FIRST FLOOR - KITCHEN SINK - INSTALL AIR CHAMBERS ON THE HOT AND COLD WATER LINES. 1136 W 104TH PL COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE 1136 FIRST FLOOR - KITCHEN SINK - REPLACE FLEXIBLE WATER SUPPLIES WITH COPPER SUPPLIES. 1136 W 104TH PL COMPLAINT FAILED View
REPLACE DEFECTIVE TRAP BASEMENT - LAUNDRY TUB TRAP, MADE WITH WATER FITTINGS, REPLACE WITH A TUBULAR TRAP. 1136 W 104TH PL COMPLAINT FAILED View
PRV CLEANOUT AT BASE OF STACK BASEMENT - INSTALL FULL SIZE CLEAN OUT ON THE THREE INCH PVC STACK. 1136 W 104TH PL COMPLAINT FAILED View
INSTALL FIXTURES PROPERLY SECOND FLOOR - TUB SPOUT AWAY FROM WALL, INSTALL PROPERLY. 1136 W 104TH PL COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE SECOND FLOOR - TUB ENAMEL CHIPPED IN NUMEROUS SPOTS, REPAIR OR REPLACE. 1136 W 104TH PL COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR. 1136 W 104TH PL COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PULL A PLUMBING PERMIT. 1136 W 104TH PL COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT METER BOX NOT SECURED TO EXTENSION WALL PROPERLY. 1136 W 104TH PL COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE REPLACE SERVICE ENTRANCE CABLE RISER BURIED BEHIND SIDING OF BUILDING. *DANGEROUS AND HAZARDOUS* 1136 W 104TH PL COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION OPEN PANEL WITH EXPOSED LIVE PARTS - PANEL COVERS MISSING. *DANGEROUS AND HAZARDOUS* 1136 W 104TH PL COMPLAINT FAILED View
PROPER SIZE OCP PROVIDE OVER CURRENT PROTECTION FOR PANEL BEING FED BY BARE WIRES BETWEEN BASEMENT AREAS. *DANGEROUS AND HAZARDOUS* 1136 W 104TH PL COMPLAINT FAILED View
CONTINUITY OF RACEWAY PROVIDE GROUND CONTINUITY FOR BARE WIRES FROM BASEMENT AREA 1134 PANEL TO BASEMENT AREA OF 1136 PANEL - AND 1136 SECOND FLOOR BATHROOM HAS BARE WIRES FROM LIGHT FIXTURE THROUGH WALL TO UNKNOWN LOCATION. *DANGEROUS AND HAZARDOUS CONDITION* 1136 W 104TH PL COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOP AREA, BATHROOM, AND LAUNDRY AREAS, AND REAR EXTERIOR RECEPTACLES. 18-27-210.8, 18-27-570.8. 1136 W 104TH PL COMPLAINT FAILED View
PROVIDE WEATHERPROOF BOXES, LIGHTS, FITTINGS, AND APPROVED RACEWAY FOR ALL FRONT AND REAR EXTERIOR AREAS. 18-27-110.11. 1136 W 104TH PL COMPLAINT FAILED View
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREA, AND GARAGE. 18-27-210.25. 1136 W 104TH PL COMPLAINT FAILED View
SEE INSPECTOR COMMENTS SERVICE DISCONNECTS SHALL BE ONE TO SIX DISCONNECTS IN A COMMON ENCLOSURE. 18-27-230.71. 1136 W 104TH PL COMPLAINT FAILED View
WIRING METHODS - SINCE BUILDING IS BEING FED BY ONE PHASE AND BRANCH CIRCUITS SHARE NEUTRALS IT IS POSSIBLE DUE TO SHARED NEUTRALS TO BE OVERLOADED AND CAUSE OF ELECTRICAL SHORT OR LOSS OF NEUTRAL WHICH RESULTS IN A DANGEROUS AND HAZARDOUS CONDITION. 18-27-110.8. 1136 W 104TH PL COMPLAINT FAILED View
PROVIDE A WATER MAIN GROUND CONDUCTOR TO WITHIN 5 FEET OF WATER METER OR VALVE. 18-27-250.2. 1136 W 104TH PL COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROPERLY BOND ALL SERVICE DISCONNECTS AND ELECTRICAL PANELS ACCORDING TO ARTICLE 250.2 - PANELS HAVE BARE WIRES WITH NO CONDUIT RUNS BETWEEN PANELS, 18-27-250.2. *DANGEROUS AND HAZARDOUS CONDITION* 1136 W 104TH PL COMPLAINT FAILED View
SEE INSPECTOR COMMENTS REMOVE ALL ABANDONED RACEWAY, BOXES, CABLE, AND ELECTRICAL EQUIPMENT AT 1136 REAR EXTERIOR AREAS OF BUILDING. 18-27-110.12E. 1136 W 104TH PL COMPLAINT FAILED View
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS. 13-12-360. 1136 W 104TH PL COMPLAINT FAILED View
REPLACE DEFECTIVE TRAP 1136 FIRST FLOOR - KITCHEN SINK - REMOVE FLEXIBLE WASTE PIPE AND REPIPE WITH RIGID TUBING. 1136 W 104TH PL COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT EAST GUTTER SECTION - MISSING AND LAYING ON GROUND. EAST DOWNSPOUT - MISSING. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR EXTERIOR DOOR NORTHWEST AT 1ST - STORM DOOR WITH BROKEN WINDOW PANE. 1136 W 104TH PL COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH PORCHES -OPEN AND PARTIALLY ENCLOSED - COLUMNS ERECTED ON CONCRETE BLOCKS - FOUNDATION STATUS UNKNOWN. UNDERSIZED 2 X 8 DECK JOISTS OVERSPANNED AT 13' . BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. NORTHWEST DECKING - ROTTED AND SAGGING. GUARD AND HANDRAILS - ''LADDER'' TYPE WITH 10'' TO 13'' BETWEEN HORIZONTAL TIES. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. 1136 W 104TH PL COMPLAINT FAILED View