Chicago Building Violations Data: 40 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL REAR ELEVATIONS WITH SPALLING BRICK, ERODED MORTAR JOINTS SECTIONS 3616 W IRVING PARK RD PERIODIC FAILED View
GRADE AND DRAIN LOT REAR AREA USED FOR VEHICLE PARKING, SEE DEPRESSIONS & UNEVEN SECTIONS. 3616 W IRVING PARK RD PERIODIC FAILED View
FLAKY INTERIOR PAINT ALL ELEVATIONS & WINDOW IN NEED OF TREATMENT, SEE ROTTING CASINGS. 3616 W IRVING PARK RD PERIODIC FAILED View
NO CLOSET/STORAGE UNDER STAIR EXCESSIVE STORAGE UNDER REAR ENCLOSED PORCH 3616 W IRVING PARK RD PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT NO GUARDRAILS 3616 W IRVING PARK RD PERIODIC FAILED View
MAINTAIN WINDOW WOOD AROUND WINDOWS FRAME WARP 3616 W IRVING PARK RD PERIODIC FAILED View
INSTALL DOOR VIEWING DEVICE DOORS NO VIEWING DEVICE 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT STAIRWELL NO HANDRAILS 3616 W IRVING PARK RD PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER ID SIGN POSTED 3616 W IRVING PARK RD PERIODIC FAILED View
INSTALL SMOKE DETECTORS 2ND FLOOR TENANT AND STAIRWELL FRONT AND REAR NO SMOKE DETECTORS 3616 W IRVING PARK RD PERIODIC FAILED View
CARB MONOX DETECT IN RESID 2ND FLOOR TENANT NO CARBON MONOXIDE DETECTOR 3616 W IRVING PARK RD PERIODIC FAILED View
MICE/RODENTS MICE THRU-OUT BUILDING 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION / EXTERIOR WALL - STEP FRACTURES AND SHIFTING BRICKS. FRONT FACE OF WALL, VERTICAL CRACK AT WEST ELEVATION. REAR OF PROPERTY - EXTERIOR WALL CRACKED AND WASHED OUT MORTAR. PERMITS REQUIRED FOR MASONRY REPAIRS. 3616 W IRVING PARK RD PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR BASEMENT STAIRS NO GUARD RAIL. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRWELL MISSING HAND RAILS FROM 2 TO 3. 3616 W IRVING PARK RD PERIODIC FAILED View
MICE/RODENTS UNIT 3 RODENT DROPPINGS. 3616 W IRVING PARK RD PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# POST I.D. 3616 W IRVING PARK RD PERIODIC FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTOR TOP OF FRONT INTERIOR STAIRS. UNIT 3 NO SMOKE DETECTOR. 3616 W IRVING PARK RD PERIODIC FAILED View
CARB MONOX DETECT IN RESID CO DETECTOR NOT OPERATING UNIT 3. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR EXTERIOR STAIR REAR EXTERIOR STAIR FROM GROUND TO 2 SEPARATING FROM BUILDING. STAIR SYSTEM WITH SWAY AND IS NOT SECURED TO BUILDING. LOOSE AND DEFLECTING RAILS. RAILS FASTENED WITH NAILS/ SCREWS ONLY. 6X6 AND 4X4 COLUMNS FOR LANDING AT 2 NOT ON 42'' FOOTINGS BUT SEATED ON FRACTURED, UNEVEN SLAB. RUSTING JOIST HANGERS. BEAMS AND COLUMNS FASTENED WITH NAILS/ SCREWS ONLY. LEDGER/ BEAMS FASTENED WITH NAILS/ SCREWS ONLY. OBTAIN PLAN AND PERMIT FOR DANGEROUS AND HAZARDOUS STAIR SYSTEM.REAR EXTERIOR BASEMENT STAIRWELL COVERED WITH LOOSE SCRAP WOOD. NO GUARD RAILS AND NO HANDRAIL. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION FRACTURES AND SHIFTING BRICK AT EAST AND WEST ENDS ABOVE IRON BEAM OVER STORE FRONT. OPEN LIMESTONE JOINTS OVER WINDOWS AT 3. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR COPING OPEN COPING STONE JOINTS SOUTH ELEVATION. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR CORNICE OPEN CORNICE JOINTS SOUTH ELEVATION. 3616 W IRVING PARK RD PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT AND REAR STAIRS OBSTRUCTED AT 3 WITH STORAGE, BAGS, CLOTHES. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR FLOOR UNIT 3 HARDWOOD FLOORS DAMAGED, MISSING AREAS, SECTIONS CAVED IN. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR FLOOR UNIT 3 HARDWOOD FLOORS DAMAGED, MISSING AREAS, SECTIONS CAVED IN. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR COPING SOUTH ELEVATION / COPING STONE - OPEN MORTAR JOINTS. 3616 W IRVING PARK RD PERIODIC FAILED View
NO CLOSET/STORAGE UNDER STAIR REAR OF PROPERTY / EXCESSIVE MATERIALS - STORED UNDER STAIRS. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR CORNICE SOUTH ELEVATION / CORNICE - OPEN MORTAR JOINTS 3616 W IRVING PARK RD PERIODIC FAILED View
NO KEY TO USE EXIT DOOR REAR OF PROPERTY / REAR DOOR - GATED WITH PAD LOCK. 3616 W IRVING PARK RD PERIODIC FAILED View
RAT STOP AROUND EXTERIOR RODENT STOPS - MISSING, LARGE BURROWS ALONG PREMISES. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR EXTERIOR STAIR REAR OF PROPERTY / 2 STORY WOODEN PORCH - STAIR SYSTEM SWAYS AND IS NOT PROPERLY ANCHORED TO THE BUILDING. WORN AND OR ROTTING TREADS, FLOOR BOARDS AND STRINGERS. LOOSE AND DEFLECTING RAILS. 6X6 AND 4X4 COLUMNS WITH INADEQUATE HALF LAPS. RUSTING JOIST HANGERS. BEAMS AND COLUMNS FASTENED WITH NAILS/ WITH MISSING AND OR RUSTING HARDWARE THROUGH OUT. LEDGER/ BEAMS FASTENED WITH NAILS / SCREWS ONLY. PLANS AND PERMITS REQUIRED FOR REPLACEMENT, DANGEROUS AND HAZARDOUS STAIR SYSTEM. 3616 W IRVING PARK RD PERIODIC FAILED View
SERVICE WALK, PASSAGE, AREAWAY WEST ELEVATION / SERVICE WALK - EXCESSIVE MATERIAL AND OR DEBRIS, TRASH CANS BLOCKING EGRESS. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTOR NOT OPERATING TOP OF REAR INTERIOR STAIR. 3616 W IRVING PARK RD PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT STAIRWAY HANDRAIL LOOSE FROM GRADE TO SECOND FLOOR . MISSING HANDRAILS FROM SECOND TO THIRD FLOORS . 3616 W IRVING PARK RD COMPLAINT FAILED View
EXPOSED WIRING FRONT STAIRWAY AT GRADE , WIRES LOOSE AND HANGING FROM MAILBOX DOORBELL PANEL . 3616 W IRVING PARK RD COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY FRONT STAIRWAY AT THIRD FLOOR LANDING , REMOVE OVERSIZED WOOD STORAGE CABINET AND RESTORE LANDING TO ORIGINAL SIZE AND WIDTH . 3616 W IRVING PARK RD COMPLAINT FAILED View
MAINTAIN WINDOW SASH FRONT AND SIDE ELEVATIONS , WOOD WINDOWS AND WOOD WINDOWS BEHIND STORM WINDOWS , ROTTED , FLAKING PAINT AND PUTTY , COLD AIR INFILTRATION . 3616 W IRVING PARK RD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED . 3616 W IRVING PARK RD COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH RAILS NOT ANCHOR TO WALL,GUARDRAILS LESS THAN 42" 3616 W IRVING PARK RD PERIODIC FAILED View