The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | REAR ELEVATIONS WITH SPALLING BRICK, ERODED MORTAR JOINTS SECTIONS | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
GRADE AND DRAIN LOT | REAR AREA USED FOR VEHICLE PARKING, SEE DEPRESSIONS & UNEVEN SECTIONS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
FLAKY INTERIOR PAINT | ALL ELEVATIONS & WINDOW IN NEED OF TREATMENT, SEE ROTTING CASINGS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | EXCESSIVE STORAGE UNDER REAR ENCLOSED PORCH | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT NO GUARDRAILS | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
MAINTAIN WINDOW | WOOD AROUND WINDOWS FRAME WARP | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL DOOR VIEWING DEVICE | DOORS NO VIEWING DEVICE | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRWELL NO HANDRAILS | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER ID SIGN POSTED | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR TENANT AND STAIRWELL FRONT AND REAR NO SMOKE DETECTORS | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR TENANT NO CARBON MONOXIDE DETECTOR | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
MICE/RODENTS | MICE THRU-OUT BUILDING | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / EXTERIOR WALL - STEP FRACTURES AND SHIFTING BRICKS. FRONT FACE OF WALL, VERTICAL CRACK AT WEST ELEVATION. REAR OF PROPERTY - EXTERIOR WALL CRACKED AND WASHED OUT MORTAR. PERMITS REQUIRED FOR MASONRY REPAIRS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRS NO GUARD RAIL. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWELL MISSING HAND RAILS FROM 2 TO 3. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
MICE/RODENTS | UNIT 3 RODENT DROPPINGS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST I.D. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR TOP OF FRONT INTERIOR STAIRS. UNIT 3 NO SMOKE DETECTOR. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | CO DETECTOR NOT OPERATING UNIT 3. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIR FROM GROUND TO 2 SEPARATING FROM BUILDING. STAIR SYSTEM WITH SWAY AND IS NOT SECURED TO BUILDING. LOOSE AND DEFLECTING RAILS. RAILS FASTENED WITH NAILS/ SCREWS ONLY. 6X6 AND 4X4 COLUMNS FOR LANDING AT 2 NOT ON 42'' FOOTINGS BUT SEATED ON FRACTURED, UNEVEN SLAB. RUSTING JOIST HANGERS. BEAMS AND COLUMNS FASTENED WITH NAILS/ SCREWS ONLY. LEDGER/ BEAMS FASTENED WITH NAILS/ SCREWS ONLY. OBTAIN PLAN AND PERMIT FOR DANGEROUS AND HAZARDOUS STAIR SYSTEM.REAR EXTERIOR BASEMENT STAIRWELL COVERED WITH LOOSE SCRAP WOOD. NO GUARD RAILS AND NO HANDRAIL. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION FRACTURES AND SHIFTING BRICK AT EAST AND WEST ENDS ABOVE IRON BEAM OVER STORE FRONT. OPEN LIMESTONE JOINTS OVER WINDOWS AT 3. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR COPING | OPEN COPING STONE JOINTS SOUTH ELEVATION. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR CORNICE | OPEN CORNICE JOINTS SOUTH ELEVATION. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT AND REAR STAIRS OBSTRUCTED AT 3 WITH STORAGE, BAGS, CLOTHES. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR FLOOR | UNIT 3 HARDWOOD FLOORS DAMAGED, MISSING AREAS, SECTIONS CAVED IN. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR FLOOR | UNIT 3 HARDWOOD FLOORS DAMAGED, MISSING AREAS, SECTIONS CAVED IN. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR COPING | SOUTH ELEVATION / COPING STONE - OPEN MORTAR JOINTS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | REAR OF PROPERTY / EXCESSIVE MATERIALS - STORED UNDER STAIRS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR CORNICE | SOUTH ELEVATION / CORNICE - OPEN MORTAR JOINTS | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR OF PROPERTY / REAR DOOR - GATED WITH PAD LOCK. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
RAT STOP AROUND EXTERIOR | RODENT STOPS - MISSING, LARGE BURROWS ALONG PREMISES. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | REAR OF PROPERTY / 2 STORY WOODEN PORCH - STAIR SYSTEM SWAYS AND IS NOT PROPERLY ANCHORED TO THE BUILDING. WORN AND OR ROTTING TREADS, FLOOR BOARDS AND STRINGERS. LOOSE AND DEFLECTING RAILS. 6X6 AND 4X4 COLUMNS WITH INADEQUATE HALF LAPS. RUSTING JOIST HANGERS. BEAMS AND COLUMNS FASTENED WITH NAILS/ WITH MISSING AND OR RUSTING HARDWARE THROUGH OUT. LEDGER/ BEAMS FASTENED WITH NAILS / SCREWS ONLY. PLANS AND PERMITS REQUIRED FOR REPLACEMENT, DANGEROUS AND HAZARDOUS STAIR SYSTEM. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST ELEVATION / SERVICE WALK - EXCESSIVE MATERIAL AND OR DEBRIS, TRASH CANS BLOCKING EGRESS. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | SMOKE DETECTOR NOT OPERATING TOP OF REAR INTERIOR STAIR. | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT STAIRWAY HANDRAIL LOOSE FROM GRADE TO SECOND FLOOR . MISSING HANDRAILS FROM SECOND TO THIRD FLOORS . | 3616 W IRVING PARK RD | COMPLAINT | FAILED | View |
EXPOSED WIRING | FRONT STAIRWAY AT GRADE , WIRES LOOSE AND HANGING FROM MAILBOX DOORBELL PANEL . | 3616 W IRVING PARK RD | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT STAIRWAY AT THIRD FLOOR LANDING , REMOVE OVERSIZED WOOD STORAGE CABINET AND RESTORE LANDING TO ORIGINAL SIZE AND WIDTH . | 3616 W IRVING PARK RD | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | FRONT AND SIDE ELEVATIONS , WOOD WINDOWS AND WOOD WINDOWS BEHIND STORM WINDOWS , ROTTED , FLAKING PAINT AND PUTTY , COLD AIR INFILTRATION . | 3616 W IRVING PARK RD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 3616 W IRVING PARK RD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH RAILS NOT ANCHOR TO WALL,GUARDRAILS LESS THAN 42" | 3616 W IRVING PARK RD | PERIODIC | FAILED | View |