Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST APPROVED OCCUPANCY CARD | OBTAIN & POST OCCUPANCY CARD FOR 1ST FLOOR | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
PARTITIONS, N/L/B - BASEMENT | SUBSTANDARD PORTIONS AT 1ST FLOOR, 3747 AREA-PARTITION WALLS BUILT ON NORTH & SOUTH END WITH PANELING | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
INTERIOR FINISH FIRERESISTANCE | PROVIDE FLAMESPREAD RATING FOR PANELED WALLS AT 1ST FLOOR | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
DOOR SWING IN DIR. OF TRAVEL | FRONT 3747 EXIT DOOR SWINGS AGAINST DIRECTION OF TRAVEL | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | REAR 3747 EXIT DOOR-30" WIDE | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | RISERS FOR PLATFORM AT 14" (2 STEPS) | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE GUARDRAIL FOR PLATFORM 30" HIGH (SEC. 13-124-320) | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE 2 HOUR CEILING AT 3751 BASEMENT STORAGE (CEILING PANELED) (SEC. 15-8-240) | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS & PERMITS FOR 1ST PARTITION WALLS, 3747 NEW COLUMN DESIGN, CONVERSION OF 3751 BASEMENT FROM STORAGE TO ASSEMBLY USE OR PERMIT TO DECONVERT BASEMENT 3751 | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
PARAPET & COPING | NORTH ELEVATION/ COPING STONEWORK, AND PARAPET WALL- FRACTURED AND BULGING MASONRY, WITH WASHED OUT MORTAR OVER PUBLIC SIDEWALK. WEST ELEVATION/ PARAPET WALL- SPALLING BRICKS, WITH WASHED OUT MORTAR. MASONRY PERMIT REQUIRED FOR ALL REPAIRS. | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
REPAIR CORNICE | NORTH ELEVATION/ CORNICE- FRACTURED AND BULGING MASONRY OVER PUBLIC SIDEWALK. MASONRY PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION/ EXTERIOR WALL- FRACTURED AND BULGING MASONRY OVER PUBLIC SIDEWALK. MASONRY PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | NORTH ELEVATION/ SILLS- FRACTURED AND BULGING MASONRY OVER PUBLIC SIDEWALK. MASONRY PERMIT REQUIRED FOR ALL MASONRY REPAIRS. | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR 2 STORY PORCH/ COLUMNS- OUT OF PLUMB, WITH BEAMS AND RIM JOISTS NOTCHED IN AT ADJACENT LOCATIONS. STRINGERS- FASTENED TO COLUMNS WITH NAILS ONLY. STAIR SECTION- OUT OF LEVEL AND SAGGING. RAILING SECTIONS- LOOSE, PULLING, ROTTED THROUGH, AND ONLY 32 INCHES HIGH. VEHICLE COLLISION PROTECTION- MISSING. PLANS AND PERMIT REQUIRED TO REPAIR: REAR EXTERIOR 2 STORY PORCH. | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |
PROTECT SIDEWALK DURING CONST | NORTH ELEVATION/ OVER PUBLIC SIDEWALK- PROVIDE PROTECTIVE CANOPY FOR ALL MASONRY REPAIRS. PERMIT IS REQUIRED [PERMIT IS AVAILABLE FROM DEPARTMENT OF TRANSPORTATION]. | 3747 W MONTROSE AVE | COMPLAINT | PASSED | View |