Chicago Building Violations Data: 29 Violations
Violation Inspector Comments Address Category Status View
PARAPET FRONT BUILDING - NORTH AND SOUTH PARAPET WALLS - LOOSE , SHIFTING , SPALLING , AND MISSING BRICKS WITH WASHED OUT MORTAR. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR CORNICE FRONT BUILDING - EAST CORNICE STONE - WASHED OUT MORTAR. 3118 N CLIFTON AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE FRONT BUILDING - NORTH ELEVATION - OVERGROWN VINES COVERING WINDOWS - BLOCKING NATURAL LIGHT AND VENTILATION. 3118 N CLIFTON AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT BUILDING - REAR BASEMENT STAIRWAY - GRADE TO BASEMENT - GUARDRAIL SECTIONS - MISSING. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT BUILDING - FRONT EXTERIOR STAIRWAY - GRADE TO 1ST - NORTH GUARDRAIL SECTION - MISSING. REAR BASEMENT STAIRWAY - GRADE TO BASEMENT - HANDRAIL - MISSING. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT BUILDING - SOUTH AND WEST WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. 3118 N CLIFTON AVE COMPLAINT FAILED View
1HR PUB.CORRIDOR IN MULT. D.U. FRONT BUILDING - SOUTH UNDERNEATH ELEVATED BAY WALL AT GRADE - PLASTER / DRYWALL SECTIONS -AT CEILING - MISSING - EXPOSED WOOD LATH. 3118 N CLIFTON AVE COMPLAINT FAILED View
PRV FLOOR DRAIN WITH METAL STR FRONT BUILDING - REAR EXTERIOR BASEMENT FLOOR DRAIN - STRAINER COVER - MISSING. 3118 N CLIFTON AVE COMPLAINT FAILED View
1-HR HEATING PLANT ENCLOSURE FRONT BUILDING - REAR INTERIOR BASEMENT WITH GAS FURNACE AND 4 GAS HOT WATER HEATERS - CEILING AND WALL AREAS - OPEN HOLES - MISSING DRYWALL WITH EXPOSED WOOD JOISTS , STUDS AND SHEATHING. 3118 N CLIFTON AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG FRONT BUILDING - REAR INTERIOR BASEMENT - FIRE EXTINGUISHER WITH EXPIRED TAG - 2007. 3118 N CLIFTON AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS FRONT BUILDING - REAR INTERIOR BASEMENT 4 GAS HOT WATER HEATERS AND 1 GAS FURNACE - 3 VENTS CONNECTED AT CHIMNEY. 3118 N CLIFTON AVE COMPLAINT FAILED View
NO CLOSET/STORAGE UNDER STAIR FRONT BUILDING - UNDER REAR PORCH STAIRS AND 1ST LEVEL DECK - STORING PERSONAL ITEMS. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR ROOF STRUCTURE FRONT BUILDING - REAR PORCH ROOF - ROTTED WITH BROKEN SECTIONS OF WOOD SHEATHING AND HOLES. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT BUILDING - REAR 3 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. BOTTOM OF MIDDLE COLUMN NOTCHED OUT . SOME COLUMN SPLICES ONLY NAILED TOGETHER. BEAMS ONLY BOLTED TO COLUMNS WITH ONE BOLT - WEAK. 2 X 8 DECK JOISTS SPAN 11' . 6 X 6 BEAMS SPAN 6'6'' AND SOME BEAMS ARE ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM AND HEADER JOISTS. ROOF BEAMS ONLY NAILED TO COLUMNS. BEAM POCKETS AT BUILDING - MISSING BRICKS AND MORTAR - OPEN. STRINGERS ONLY NAILED TO HEADER JOISTS , DECK JOISTS , AND COLUMNS. STAIR TREADS - LOOSE , ROTTED , SPLIT , AND ONLY 9 1/4'' WIDE. STAIR HEAD ROOM - GRADE TO 1ST - ONLY 6'6''. LARGE 7'' TO 9''GAPS AT STAIR TREADS TO RAILINGS . STAIR RAILS - LOOSE WITH LOOSE PICKETS. GUARDRAILS ONLY 36'' HIGH AND LOOSE. PLANS AND PERMIT REQUIRED FOR FRONT BUILDING REAR PORCH REPAIRS. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR BUILDING - EAST STAIRWAY - GRADE TO 1ST - BEAMS ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM JOISTS. STRINGERS ONLY NAILED TO HEADER JOISTS , DECK JOISTS , AND COLUMNS. TREADS ONLY 9 1/4'' WIDE. DECKING - LOOSE AND BUCKLED - TRIP HAZARD. STAIR RAILS - LOOSE WITH LOOSE AND MISSING PICKETS. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR REAR BUILDING EAST ENTRY DOORS AT 1ST - RUSTED. 3118 N CLIFTON AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG REAR BUILDING - EAST INTERIOR ENTRY WAY - FIRE EXTINGUISHER - TAG MISSING ON THE FLOOR - EXPIRED DATE 2007. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR AREAWAY WALL REAR BUILDING - WEST BASEMENT RETAINING WALL - BOWED AND FRACTURED CONCRETE. 3118 N CLIFTON AVE COMPLAINT FAILED View
RATS REAR BUILDING AT WEST BASEMENT AND GRADE - RATS AND RAT HARBORAGE. 3118 N CLIFTON AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS REAR BUILDING - 2 B - VENTS - GOING THROUGH WEST PORCH IN 2 DIFFERENT AREAS. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR ROOF STRUCTURE REAR BUILDING - WEST PORCH ROOF - RAFTERS BROKEN , ROTTED AND SCABBED WITH 2 X MATERIAL. PLANS AND PERMIT FOR WEST PORCH ROOF REPAIRS. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR BUILDING - WEST 2 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKNOWN. BEAMS ONLY CONNECTED TO COLUMNS WITH ONE BOLT. SOME BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO HEADER JOISTS , COLUMNS , AND DECK JOISTS. STAIR HEADROOM IN FRONT OF 1ST FLOOR APARTMENT DOOR IS ONLY 5'5'' OBSTRUCTING EGRESS. DECKING IS LOOSE , BUCKLED , AND SPONGY - TRIP HAZARD. GUARDRAILS ARE ONLY 36'' HIGH WITH LOOSE , BROKEN , FALLING , AND MISSING PICKETS. GUARDRAILS AND HANDRAILS ARE LOOSE . SOME GUARDRAILS WITH PICKETS NAILED INTO RIM BEAMS AND RIM JOISTS. SPLIT TOP HANDRAIL AT 2ND LEVEL. PLANS AND PERMIT REQUIRED FOR REAR BUILDING - 2 STORY OPEN WOOD PORCH REPAIRS. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR DOWNSPOUT REAR BUILDING - SOUTHWEST DOWNSPOUT SECTION AT GRADE - MISSING. 3118 N CLIFTON AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION FRONT AND REAR BUILDINGS - INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS OR VERIFY COMPLAINTS OF WATER LEAKS AND HOLES IN BUILDING FOUNDATIONS. 3118 N CLIFTON AVE COMPLAINT FAILED View
INSTALL COVERS FRONT BUILDING - REAR INTERIOR BASEMENT - ELECTRICAL SWITCH COVER - MISSING. 3118 N CLIFTON AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS FRONT BUILDING - REAR INTERIOR BASEMENT - CEILING - ELECTRICAL JUNCTION BOXES - COVERS MISSING. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR GUTTER FRONT BUILDING - WEST GUTTER - RUSTED AND TIPPED. 3118 N CLIFTON AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR EXTERIOR WOOD PORCHES [MAIN AND COACH HOUSE] /UNDERSIDE OF PORCH ROOF - ROTTED SECTIONS WITH PEELING PAINT THROUGHOUTREAR EXTERIOR WOOD PORCHES [MAIN AND COACH HOUSE] - PICKETS ON OUTSIDE OF GUARDRAILS; MISSING HANDRAIL IN SOME SECTIONS; MISSING TOP GUARDRAIL IN SOME SECTIONS; WORN, WEATHERED TREADS; UNDERSIZED 1/2 LAP WITH ONLY 2 BOLTS. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. SUBJECT TO FIELD INSPECTION AND APPROVAL. 3118 N CLIFTON AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL NORTH AND SOUTH ELEVATIONS - SPALLED BRICKS WITH WASHED OUT MORTAR [MULTIPLE LOCATIONS]. 3118 N CLIFTON AVE COMPLAINT CLOSED View