The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET | FRONT BUILDING - NORTH AND SOUTH PARAPET WALLS - LOOSE , SHIFTING , SPALLING , AND MISSING BRICKS WITH WASHED OUT MORTAR. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT BUILDING - EAST CORNICE STONE - WASHED OUT MORTAR. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | FRONT BUILDING - NORTH ELEVATION - OVERGROWN VINES COVERING WINDOWS - BLOCKING NATURAL LIGHT AND VENTILATION. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT BUILDING - REAR BASEMENT STAIRWAY - GRADE TO BASEMENT - GUARDRAIL SECTIONS - MISSING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT BUILDING - FRONT EXTERIOR STAIRWAY - GRADE TO 1ST - NORTH GUARDRAIL SECTION - MISSING. REAR BASEMENT STAIRWAY - GRADE TO BASEMENT - HANDRAIL - MISSING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT BUILDING - SOUTH AND WEST WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
1HR PUB.CORRIDOR IN MULT. D.U. | FRONT BUILDING - SOUTH UNDERNEATH ELEVATED BAY WALL AT GRADE - PLASTER / DRYWALL SECTIONS -AT CEILING - MISSING - EXPOSED WOOD LATH. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | FRONT BUILDING - REAR EXTERIOR BASEMENT FLOOR DRAIN - STRAINER COVER - MISSING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | FRONT BUILDING - REAR INTERIOR BASEMENT WITH GAS FURNACE AND 4 GAS HOT WATER HEATERS - CEILING AND WALL AREAS - OPEN HOLES - MISSING DRYWALL WITH EXPOSED WOOD JOISTS , STUDS AND SHEATHING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FRONT BUILDING - REAR INTERIOR BASEMENT - FIRE EXTINGUISHER WITH EXPIRED TAG - 2007. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | FRONT BUILDING - REAR INTERIOR BASEMENT 4 GAS HOT WATER HEATERS AND 1 GAS FURNACE - 3 VENTS CONNECTED AT CHIMNEY. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | FRONT BUILDING - UNDER REAR PORCH STAIRS AND 1ST LEVEL DECK - STORING PERSONAL ITEMS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | FRONT BUILDING - REAR PORCH ROOF - ROTTED WITH BROKEN SECTIONS OF WOOD SHEATHING AND HOLES. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING - REAR 3 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. BOTTOM OF MIDDLE COLUMN NOTCHED OUT . SOME COLUMN SPLICES ONLY NAILED TOGETHER. BEAMS ONLY BOLTED TO COLUMNS WITH ONE BOLT - WEAK. 2 X 8 DECK JOISTS SPAN 11' . 6 X 6 BEAMS SPAN 6'6'' AND SOME BEAMS ARE ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM AND HEADER JOISTS. ROOF BEAMS ONLY NAILED TO COLUMNS. BEAM POCKETS AT BUILDING - MISSING BRICKS AND MORTAR - OPEN. STRINGERS ONLY NAILED TO HEADER JOISTS , DECK JOISTS , AND COLUMNS. STAIR TREADS - LOOSE , ROTTED , SPLIT , AND ONLY 9 1/4'' WIDE. STAIR HEAD ROOM - GRADE TO 1ST - ONLY 6'6''. LARGE 7'' TO 9''GAPS AT STAIR TREADS TO RAILINGS . STAIR RAILS - LOOSE WITH LOOSE PICKETS. GUARDRAILS ONLY 36'' HIGH AND LOOSE. PLANS AND PERMIT REQUIRED FOR FRONT BUILDING REAR PORCH REPAIRS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BUILDING - EAST STAIRWAY - GRADE TO 1ST - BEAMS ONLY NAILED TO COLUMNS. DECK JOISTS ONLY NAILED TO RIM JOISTS. STRINGERS ONLY NAILED TO HEADER JOISTS , DECK JOISTS , AND COLUMNS. TREADS ONLY 9 1/4'' WIDE. DECKING - LOOSE AND BUCKLED - TRIP HAZARD. STAIR RAILS - LOOSE WITH LOOSE AND MISSING PICKETS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR BUILDING EAST ENTRY DOORS AT 1ST - RUSTED. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | REAR BUILDING - EAST INTERIOR ENTRY WAY - FIRE EXTINGUISHER - TAG MISSING ON THE FLOOR - EXPIRED DATE 2007. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | REAR BUILDING - WEST BASEMENT RETAINING WALL - BOWED AND FRACTURED CONCRETE. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
RATS | REAR BUILDING AT WEST BASEMENT AND GRADE - RATS AND RAT HARBORAGE. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | REAR BUILDING - 2 B - VENTS - GOING THROUGH WEST PORCH IN 2 DIFFERENT AREAS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | REAR BUILDING - WEST PORCH ROOF - RAFTERS BROKEN , ROTTED AND SCABBED WITH 2 X MATERIAL. PLANS AND PERMIT FOR WEST PORCH ROOF REPAIRS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR BUILDING - WEST 2 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKNOWN. BEAMS ONLY CONNECTED TO COLUMNS WITH ONE BOLT. SOME BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO HEADER JOISTS , COLUMNS , AND DECK JOISTS. STAIR HEADROOM IN FRONT OF 1ST FLOOR APARTMENT DOOR IS ONLY 5'5'' OBSTRUCTING EGRESS. DECKING IS LOOSE , BUCKLED , AND SPONGY - TRIP HAZARD. GUARDRAILS ARE ONLY 36'' HIGH WITH LOOSE , BROKEN , FALLING , AND MISSING PICKETS. GUARDRAILS AND HANDRAILS ARE LOOSE . SOME GUARDRAILS WITH PICKETS NAILED INTO RIM BEAMS AND RIM JOISTS. SPLIT TOP HANDRAIL AT 2ND LEVEL. PLANS AND PERMIT REQUIRED FOR REAR BUILDING - 2 STORY OPEN WOOD PORCH REPAIRS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR BUILDING - SOUTHWEST DOWNSPOUT SECTION AT GRADE - MISSING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | FRONT AND REAR BUILDINGS - INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS OR VERIFY COMPLAINTS OF WATER LEAKS AND HOLES IN BUILDING FOUNDATIONS. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | FRONT BUILDING - REAR INTERIOR BASEMENT - ELECTRICAL SWITCH COVER - MISSING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | FRONT BUILDING - REAR INTERIOR BASEMENT - CEILING - ELECTRICAL JUNCTION BOXES - COVERS MISSING. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | FRONT BUILDING - WEST GUTTER - RUSTED AND TIPPED. | 3118 N CLIFTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR EXTERIOR WOOD PORCHES [MAIN AND COACH HOUSE] /UNDERSIDE OF PORCH ROOF - ROTTED SECTIONS WITH PEELING PAINT THROUGHOUTREAR EXTERIOR WOOD PORCHES [MAIN AND COACH HOUSE] - PICKETS ON OUTSIDE OF GUARDRAILS; MISSING HANDRAIL IN SOME SECTIONS; MISSING TOP GUARDRAIL IN SOME SECTIONS; WORN, WEATHERED TREADS; UNDERSIZED 1/2 LAP WITH ONLY 2 BOLTS. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 3118 N CLIFTON AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUTH ELEVATIONS - SPALLED BRICKS WITH WASHED OUT MORTAR [MULTIPLE LOCATIONS]. | 3118 N CLIFTON AVE | COMPLAINT | CLOSED | View |