Chicago Building Violations Data: 42 Violations
Violation Inspector Comments Address Category Status View
OPEN TYPE VIOLATION PERFORM PRESSURE RELIEF AND HYDRAULIC SYSTEM TEST. TAG VALVE AND SEND TEST RESULTS TO THE ELEVATOR BUREAU. 18-30-010,13-20-120. 4040 N SHERIDAN RD PERIODIC FAILED View
REP/REPL DEF ALARM BELL PASS REPAIR 24HOUR EMERGENCY PHONES. 4040 N SHERIDAN RD PERIODIC PASSED View
INST PROP RACEWAYS FOR WIRING COVERS MISSING ON BOXES IN PITS. 18-27-620. 4040 N SHERIDAN RD PERIODIC PASSED View
OPEN TYPE VIOLATION 1. PROPERLY BACKFILL AND GRANT PASSENGER ELEVATOR CYLINDERS IN ELEVATOR PITS. 18-30-010, 13-20-120. 4040 N SHERIDAN RD PERIODIC PASSED View
OPEN TYPE VIOLATION 2. PERFORM ANNUAL PRESSURE RELIEF TEST FOR BOTH PASSENGER ELEVATORS; SEAL & TAG VALVES; SUBMIT TEST REPORTS TO CITY OF CHICAGO ELEVATOR BUREAU. 1005.2 (A). 4040 N SHERIDAN RD PERIODIC PASSED View
OPEN TYPE VIOLATION 3. I.D. CARS AT EACH LANDING. 18-30-2620. 18-30-010, 13-20-120. EV018763. 4040 N SHERIDAN RD PERIODIC PASSED View
REPAIR FLOOR APARTMENT 607 CARPET ON FLOOR EXCESSIVE BURN MARKS. 4040 N SHERIDAN RD COMPLAINT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA NORTH ELEVATOR OUT FOR MONTHS CHALLENGED PEOPLE IN BLDG. REPAIR OR REMOVE FROM SERVICE PROPERLY AFTER PULLING PERMIT 4040 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE CURRENT CERTS 4040 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA CAT-1 TEST TO BE PERFORMED. BOTH CARS 4040 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR NORTH CAR PHASE11 4040 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA CAT-1 TEST TO BE PERFORMED 4040 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CAT-1 TESTS 4040 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL LONGEST TOE GUARD AS POSSIBLE AND APPLY FOR VARIANCE . 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA RE3PAIR FIRE SERVICE JEWEL. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL LOBBY PANEL WITH APPROPRIATE KEY SWITCHES. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR P.I. IN CAR. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL CAR TOP HAND RAILS. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL FIRE ANGLES ON ALL HOISTWAY DOORS. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR STOP SWITCH IN CAR FIRESERVICE PANEL TO OPERATE PROPERLY. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA LABEL DISCONNECTS IN MACHINE ROOM. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVBIDE CROSSBAR ON PIT LADDERS. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE TEMPERATURE CONTROL IN MACHINE ROOM. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PATCH HOLES ON SOUTH HOISTWAY WALL AND AROUND HALL BUTTONS. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL IN CASE OF FIRE SIGNS AT EVERY FLOOR. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST BATTERY LOWERING. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST FAID'S , PHASE 1 AND 2. 4040 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST LOBBY PANEL FIRE SERVICE KEY SWITCH.WITH CARS AT ALTERNATE LEVEL. 4040 N SHERIDAN RD PERMIT PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST LOBBY AND MEZZANINE FLOW SWITCH. 4040 N SHERIDAN RD PERMIT PASSED View
SELF-CLOSE CLASS B FIRE DOOR TRASH CHUTE DOORS [ALL FLOORS] - NOT CLOSING, NO POSITIVE LATCH. 4040 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN EXIT SIGN ILLUMINATED 9TH FLOOR, AND MECHANICAL ROOM EXIT SIGNS - NOT ILLUMINATED. 4040 N SHERIDAN RD COMPLAINT FAILED View
ILLUMINATE PUBLIC STAIR/HALL 8TH, 3RD, 2ND FLOORS - EMERGENCY LIGHTS - OUT OF SERVICE. 4040 N SHERIDAN RD COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER APT.808 /WALLS - PEELING PAINT. 4040 N SHERIDAN RD COMPLAINT FAILED View
CARB MONOX DETECT IN RESID APTS. 402, 312, 310, M-1, /CARBON MONOXIDE DETECTOR - MISSING. 4040 N SHERIDAN RD COMPLAINT FAILED View
PROVIDE OUTSIDE AIR SUPPLY OUTSIDE AIR INTAKE SHALL BE SIZED SO THAT AT LEAST 100% OF CODE REQUIREMENTS 4040 N SHERIDAN RD COMPLAINT FAILED View
OPEN TYPE VIOLATION CORRIDOR MAKE UP AIR SYSTEM SHALL BE SIZED TO EQUAL OF TOILET, KITCHEN & DRYER EXHAUST 18-8-501.4,18-28-403.3 4040 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE COMPLETED PERMIT INSP. ARRANGE INSPECTION 18-28-106 4040 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR NORTH CAR PHASE II OPERATION. 4040 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA TEST BATTERY LOWERING. 4040 N SHERIDAN RD PERMIT FAILED View
REPAIR/REPLACE SMOKE DETECTORS APT.303 /SMOKE DETECTOR - LOW BATTERY. 4040 N SHERIDAN RD COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG UNIT 611 4040 N SHERIDAN RD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION ARRANGE FOR INSPECTION AFTER REPAIRS - (312) 743-0413 4040 N SHERIDAN RD COMPLAINT FAILED View