ARRANGE PREMISE INSPECTION | NO ENTRY 1ST AND BASEMENT | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | SR 07 01844883 NO OWNERSHIP POSTED | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT STAIRWELL 1ST TO 2ND HOLES IN PLASTER | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT BASEMENT STAIRS NO HAND RAIL | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT BASEMENT NO GUARD RAIL | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE TRAP | 2ND BATH AND KITCHEN TRAP LEAKING | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | REAR BEDROOM DOOR LOOSE HINGES AT 2ND | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 2ND KITCHEN FLOOR BROKEN TILE | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | REAR 2ND ROTTEN SASH | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR EAVES | SOUTH EAST EAVES HOLES | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | EAST STAIRS TO 2ND NO LIGHTS | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD JUNK AND DEBRIS | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR STOOP | REAR AT GRADE BROKEN STOOP | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE ROTTEN SERVICE DOOR LOOSE SIDING | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR GRADE TO 2ND ROTTEN TREADS, LADDER RAILS NO FOOTING 4X4 COLUMNS RAILS TOO LOW OBTAIN PLANS AND PERMIT FOR REPAIRS | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY NO CAPPING REAR | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE TO INTERIOR TO VERIFY OCCUPANCY, DETECTORS, AND VERIFY COMPLAINT OF MICE, RODENTS, AND UTILTY ACCESS. | 8855 S WALLACE ST | COMPLAINT | CLOSED | View |
REPAIR GUTTER & DOWNSPOUT | EXTERIOR SOUTH TOWARDS REAR DOWNSPOUT DICONNECTED FROM GUTTER. | 8855 S WALLACE ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO VERIFY COMPLAINTS OF RODENTS, MOLD AND ROOF LEAKAGE. | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | EXTERIOR SOUTH TOWARDS REAR DOWNSPOUT DICONNECTED FROM GUTTER. | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES/ OVERHANG ROTTED. | 8855 S WALLACE ST | COMPLAINT | CLOSED | View |
REPAIR ROOF | SOUTH ELEVATION / ROOF - MISSING SHINGLES. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 2 STORY WOOD PORCH / 6X6 COLUMNS AT STRINGER LOCATIONS SPLITTING. 1 COLUMN ERECTED ON CONCRETE SLAB AND ONE ERECTED ON DIRT, FOUNDATION STATUS UNKNOWN. 2ND FLOOR DECK MOVES WHEN SHAKEN. STAIR SYSTEM IS PITCHED DOWNWARD THE FLIGHT OF STAIRS ARE VERY STEEP, CAUSING A TRIPPING HAZARD. STAIRS STRINGERS LEADING FROM 2ND FLOOR TO LANDING ARE PITCHED OUT OF LEVEL. STRINGERS ARE FASTENED WITH NAILS ONLY. ALL RAILING SYSTEMS ARE FASTENED WITH NAILS ONLY. STAIR TREADS - ROTTING.SOUTH ELEVATION 1ST FLOOR PORCH / 4X4 COULMNS NOTCHED TO ACCEPT RIM JOIST. GUARD RAIL IS OVER SPANNED AND MEASURES ONLY 36 INCHES. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. PERMIT REQUIRE TO REPAIR PORCHES. | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH AND SOUTH ELEVATIONS / GUTTERS AND DOWNSPOUTS - RUSTING AND MISSING. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 2 STORY WOOD PORCH / 6X6 COLUMNS AT STRINGER LOCATIONS SPLITTING. 1 COLUMN ERECTED ON CONCRETE SLAB AND ONE ERECTED ON DIRT, FOUNDATION STATUS UNKNOWN. 2ND FLOOR DECK MOVES WHEN SHAKEN. STAIR SYSTEM IS PITCHED DOWNWARD THE FLIGHT OF STAIRS ARE VERY STEEP, CAUSING A TRIPPING HAZARD. STAIRS STRINGERS LEADING FROM 2ND FLOOR TO LANDING ARE PITCHED OUT OF LEVEL. STRINGERS ARE FASTENED WITH NAILS ONLY. ALL RAILING SYSTEMS ARE FASTENED WITH NAILS ONLY. STAIR TREADS - ROTTING.SOUTH ELEVATION 1ST FLOOR PORCH / 4X4 COULMNS NOTCHED TO ACCEPT RIM JOIST. GUARD RAIL IS OVER SPANNED AND MEASURES ONLY 36 INCHES. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. PERMIT REQUIRE TO REPAIR PORCHES. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |
REPAIR EAVES | EAVES - OVERHANG ROTTING. | 8855 S WALLACE ST | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION / REAR CHIMNEY - WASHED OUT MORTAR. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |
REPAIR EAVES | BUILDING - WOOD EAVES - ROTTING WOOD. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / OWNER'S ID SIGN - MISSING. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / EXTERIOR WALL - ROTTING SIDING. | 8855 S WALLACE ST | COMPLAINT | PASSED | View |